32
5.2.5.1 Low Voltage Protection Settings
Five voltage protection options for user to select: Close(close the protection), return(auto
home landing), Hang(hovering),Land(auto landing), Hang-Land(hovering and then
landing). User could choose the one suitable.
The default is Return(Home landing).
5.2.5.2 Alarm Voltage Settings
Settings of first alarm and second alarm.It’s recommended to 43.6V for the first
alarm and 43.1V for second alarm.
LED will flash yellow triple when get to the first alarm level;LED will flash rapidly when get
to the second alarm level,copter will react as the low voltage settings,such as return to
home or landing.
5.2.5.3 Voltage Calibration Settings
Flight controller voltage sensor need to be calibrated if flight controller voltage sensor
result is different from real voltage.Real battery voltage should be filled in measured
voltage,flight controller voltage will be calibrated by clicking save.
It’s unnecessary to set
by user as calibration has been done before delivery.5.2.5.4 Low Liquid Protection