- 12 -
(1) The equipment employs natural convection cooling, and it can be installed indoor or outdoor.
(2) Please install the equipment under the guidance of Figure4.1. Vertical installation on floor level is
recommended. Mount vertically or tilted backwards by max. 15°. Never install the inverter tilted forwards,
sideways, horizontally or upside down.
(3) Install the inverter at eye level for convenience when checking the LCD display and possible maintenance
activities.
(4) When mounting the inverter, please consider that disassembly for service work may be required.
4.3.2 Installation Position
Do not expose the inverter to direct solar irradiation as this could cause power derating due to overheating. The
ambient temperature should be between -25°C
~
+60°C
(
-13° F
~
140° F
)
to ensure optimum operation.
Choose locations with sufficient air exchange. Ensure additional ventilation, if necessary.
To make sure the installation spot is suitably ventilated, if multiple TSUN hybrid solar inverters are
installed at same area, the following safety clearance in Figure 4.2 shall be followed.
50CM
30CM
50CM
30CM
30CM
Figure 4.2 Minimum Clearance
4.4 Mounting Procedure
4.4.1 Mark the Positions of the Drill Holes of the Rear Panel
The mounting position should be marked as shown in Figure 4.3.