7 Commands for parameter set up
41
<
7-3 Acceleration and deceleration Rate Setting
<ch>: 0 ~ F(Hexadecimal) for channel.
Command SPD<sp>?<ch>
Confirmed the speed for HSPD, NSPD, HSPD.
Argument
H/HSPD M/MSPD L/LSPD
Display the speed of the setting value in the motor.
Reply DDDDDD (
Integer of 6 or more digits
)
Example SPDL?F reply: 000050 LSPD of chF is 50pps.
Remarks
Command SPDAL?
Display the speed that has been set to the motor that displays in LCD.
Reply
<0123>/<sp>dddddd/<sp>dddddd/<sp>dddddd/<sp>dddddd
<0123>
Expressed in hexadecimal notation of four-digit channel which is
displayed on the display. Display the following parameters in this
order.
<sp>
H/HSPD M/MSPD L/LSPD
Display the speed that has been set to the motor.
dddddd
Display the speed as pps.
Example SPDAL? Reoky: 0123/M000650/H010000/L000100/M000650
Remarks
If the motor is in operation, display of dddddd part appears in 000000.
Command RTE<ch><cd>
Set the code in the acceleration and deceleration rate.
Argument <cd>
acceleration and
deceleration code
Enter the code a number between 0 - 115.
Refer to page 64 about the relationship of acceleration and
deceleration of the actual code.
Initial
value
013
Reply Nothing
Example RTE040 Set to 40 for the acceleration and deceleration rate of CH0.
Remarks Only remote mode. And the motor is stopped.
Command RTE?<ch>
Confirm the code in the acceleration and deceleration rate.
Reply DDD (
3-digit integer
)
Example RTE?0 reply: 050 The acceleration and deceleration rate of CH0 is 50.
Remarks