background image

 

TallyMan V1.81 on | Safety 

41

 

 

Safety 

Installation  

Unless otherwise stated TSL equipment may be installed at any angle or position within an operating 
temperature range of 5 ~ 25 degrees C.  
The RJ45 connectors are for use only with TSL UMD equipment.  
All TSL equipment conforms to the EC Low Voltage Directive:  
EC Low Voltage Directive (73/23/EEC) (OJ L76 26.3.73) (LVD).  
Amendment: (93/68/EEC) (OJ L220 30.8.93).  

Earthing/Grounding 

In all cases, the frame of the equipment should be earthed on installation. Connection to an earthed 

strip running the length of the frame is ideal.  

The earth pin on the IEC mains inlet connector is connected to the metal frame of the equipment, to 

0 volts on the internal DC PSU and to signal ground, unless otherwise stated. All metal panels are 

bonded together. Rack mounted equipment must be earthed (grounded).  

Mounting 

Careful consideration of the equipment location and mounting in racks must be made. In particular, 

consideration must be given to the stability of free-standing racks by mounting heavy equipment low 

in the rack. The rear of the unit should be supported in the rack.  

Power 

For pluggable equipment, the socket outlet shall be installed near the equipment and shall be easily 

accessible.  

Consideration must be given to the supply circuit loading and switch on/fault surges that will affect 

over current protection trips and switches etc.  

Check that the fuse rating is correct for the local power (mains) supply. Replacement fuses must be 

of the same rating and type for continued protection against fire risk.  

The equipment rating is shown on the rear panel.  

No power supply cord is provided with this equipment.  

Do not switch on until all connections are made.  

Ventilation 

Due consideration for cooling requirements must be given when mounting the equipment.  

If the equipment is installed in a closed unit, consideration must be given to providing forced air 

cooling in order that the maximum recommended temperature is not exceeded. Introduction 9 

TallyMan V 1.7.1b on  

 

Back to Top ^

 

 

Содержание Tallyman TM1

Страница 1: ...TallyMan V1 81 on Introduction 1 Tallyman Controller Installation Manual...

Страница 2: ...18 Initial setup 18 TM2 21 Connections 21 Pin out details 22 Default IP 28 Initial setup 28 TMC 1 31 Connections 31 Pin out details 32 Default IP 34 Initial setup 34 Specification 35 TM1 35 Internal...

Страница 3: ...y 41 Installation 41 Earthing Grounding 41 Mounting 41 Power 41 Ventilation 41 EC Declaration of conformity 42 Warranty Maintenance and Repair 43 Failure during warranty 43 Technical support informati...

Страница 4: ...llyMan Controller distributes power and provides the control for the displays It also carries user defined interfaces for routing matrices vision mixers and output drivers for cue lights and additiona...

Страница 5: ...able Used for Mixer Router Multiviewer connection Control 2 RS422 User Assignable Used for Mixer Router Multiviewer connection Control 3 RS232 User Assignable Used for Serial configuration of Controll...

Страница 6: ...the configuring computer is as follows Signal Name RJ 45 Ethernet Pin Numbers Crossover Cable Pinouts TX 1 3 TX 2 6 RX 3 1 EPWR Power 4 4 EPWR Power 5 5 RX 6 2 EPWR Power 7 7 EPWR Power 8 8 For a hub...

Страница 7: ...DTR 9 5 0v Control Port 4 Serial RS422 Display Ports RJ45 DISPLAY CONNECTORS 1 0v 2 0v 3 RX 4 TX 5 TX 6 RX 7 24v 8 24v The Display ports are wired pin to pin all 8 display ports are paralleled and are...

Страница 8: ...4 12 24V see note 16 TALLY 16 35 Ext Voltage Ref Pin 17 TALLY 17 36 0v 18 TALLY 18 37 19 TALLY 19 Parallel GPI tallies are connected directly to the Tally 1 and Tally 2 D37 connectors on the TM1 contr...

Страница 9: ...24V supply rated at 0 5A Do not use this internal 12V for relay coil supply 2 Pin 35 LK1 on the internal EAB2 cards is set for the pull up resistors to be referenced to normally 5V or by changing the...

Страница 10: ...ubnet Mask 255 255 255 0 Connection for configuration purposes is via a PC running TallyMan available for download from the TSL website www TSL co uk Initial setup Connect a PC running a terminal prog...

Страница 11: ...cts section of the TallyMan configuration manual Pressing B will set the unit as a Redundant Backup unit See the section on Backup for information on how to use this facility Pressing D will delete th...

Страница 12: ...TallyMan V1 81 on Installation 12 PC TM1 2 3 3 2 5 5 Back to Top...

Страница 13: ...ignable Used for Mixer Router Multiviewer connection Control 3 RS232 User Assignable Used for Serial configuration of Controller Network settings and available for Mixer Router Multiviewer connection...

Страница 14: ...h the configuring computer is as follows Signal Name RJ 45 Ethernet Pin Numbers Crossover Cable Pinouts TX 1 3 TX 2 6 RX 3 1 EPWR Power 4 4 EPWR Power 5 5 RX 6 2 EPWR Power 7 7 EPWR Power 8 8 For a hu...

Страница 15: ...DTR 9 5 0v Control Port 4 Serial RS422 Display Ports RJ45 DISPLAY CONNECTORS 1 0v 2 0v 3 RX 4 TX 5 TX 6 RX 7 24v 8 24v The Display ports are wired pin to pin all 8 display ports are paralleled and ar...

Страница 16: ...Y 15 34 12 24V see note 16 TALLY 16 35 Ext Voltage Ref Pin 17 TALLY 17 36 0v 18 TALLY 18 37 19 TALLY 19 Parallel GPI tallies are connected directly to the Tally 1 2 3 4 D37 connectors on the TM2 contr...

Страница 17: ...24V supply rated at 0 5A Do not use this internal 12V for relay coil supply 2 Pin 35 LK1 on the internal EAB2 cards is set for the pull up resistors to be referenced to normally 5V or by changing the...

Страница 18: ...ubnet Mask 255 255 255 0 Connection for configuration purposes is via a PC running TallyMan available for download from the TSL website www TSL co uk Initial setup Connect a PC running a terminal prog...

Страница 19: ...s section of the TallyMan configuration manual Pressing B will set the unit as a Redundant Backup unit See the section on Backup for information on how to use this facility Pressing D will delete the...

Страница 20: ...TallyMan V1 81 on Installation 20 Back to Top PC TM2 2 3 3 2 5 5...

Страница 21: ...ble Used for Mixer Router Multiviewer connection Control 3 RS232 User Assignable Used for Serial configuration of Controller Network settings and available for Mixer Router Multiviewer connection Cont...

Страница 22: ...h the configuring computer is as follows Signal Name RJ 45 Ethernet Pin Numbers Crossover Cable Pinouts TX 1 3 TX 2 6 RX 3 1 EPWR Power 4 4 EPWR Power 5 5 RX 6 2 EPWR Power 7 7 EPWR Power 8 8 For a hu...

Страница 23: ...4 DTR 9 5 0v Control Port 4 Serial RS422 Display Ports RJ45 DISPLAY CONNECTORS 1 0v 2 0v 3 RX 4 TX 5 TX 6 RX 7 24v 8 24v The Display ports are wired pin to pin all 8 display ports are paralleled and a...

Страница 24: ...nnected to pin 36 TALLY 1 INPUT CONNECTORS D37 SOCKET 1 TALLY 1 20 TALLY 20 2 TALLY 2 21 TALLY 21 3 TALLY 3 22 TALLY 22 4 TALLY 4 23 TALLY 23 5 TALLY 5 24 TALLY 24 6 TALLY 6 25 TALLY 25 7 TALLY 7 26 T...

Страница 25: ...ally 34 uses pins 3 4 Tally out 35 uses pins 5 6 TALLY 2 OUTPUT CONNECTOR D37 SOCKET 1 TALLY 33 20 TALLY 42 2 TALLY 33 21 TALLY 43 3 TALLY 34 22 TALLY 43 4 TALLY 34 23 TALLY 44 5 TALLY 35 24 TALLY 44...

Страница 26: ...14 TALLY 55 33 0v 15 TALLY 56 34 24V 16 TALLY 56 35 Ext Voltage Ref Pin 17 TALLY 57 36 0v 18 TALLY 57 37 19 TALLY 58 TALLY 4 OUTPUT CONNECTOR D37 SOCKET 1 TALLY 65 20 TALLY 74 2 TALLY 65 21 TALLY 75 3...

Страница 27: ...renced to normally 5V or by changing the link to positions Centre Ext an external voltage reference applied to Pin 35 on the D37 connector If using an external voltage above 5V the link on the card sh...

Страница 28: ...ubnet Mask 255 255 255 0 Connection for configuration purposes is via a PC running TallyMan available for download from the TSL website www TSL co uk Initial setup Connect a PC running a terminal prog...

Страница 29: ...s section of the TallyMan configuration manual Pressing B will set the unit as a Redundant Backup unit See the section on Backup for information on how to use this facility Pressing D will delete the...

Страница 30: ...TallyMan V1 81 on Installation 30 PC TM2 2 3 3 2 5 5 Back to Top...

Страница 31: ...1 RS422 User Assignable Used for Mixer Router Multiviewer connection Control 2 RS422 User Assignable Used for Mixer Router Multiviewer connection Controls 3 18 RS422 Optional expansion cards User Ass...

Страница 32: ...th the configuring computer is as follows Signal Name RJ 45 Ethernet Pin Numbers Crossover Cable Pinouts TX 1 3 TX 2 6 RX 3 1 EPWR Power 4 4 EPWR Power 5 5 RX 6 2 EPWR Power 7 7 EPWR Power 8 8 For a h...

Страница 33: ...hassis Serial Ports 3 18 RS422 Important Note The pinout of the expansion card RS422 ports will differ from the RS422 serial port 2 Different expansion cards have been used over time dependant upon cu...

Страница 34: ...a PC running TallyMan available for download from the TSL website www TSL co uk Initial setup Connect a monitor keyboard and mouse to the VGA and USB ports respectively Log into the machine with the...

Страница 35: ...ad Protection 110 150 of rated current auto recovery Over Voltage Protection 112 132 of output voltage crowbar Efficiency 70 88 dependent on unit Line Regulation 0 5 typically Load Regulation 3 typica...

Страница 36: ...et Auto Recovery Over Voltage Protection 27 6 32 4V Fan Control Over Temp Protect RTH1 or RTH2 50 C Fan On 45 C Fan Off 70 C Output Shutdown Temp Coefficient 0 03 C 0 50 C Setup Rise Hold up Time 1 5s...

Страница 37: ...TallyMan V1 81 on Specification 37...

Страница 38: ...et Auto Recovery Over Voltage Protection 27 6 32 4V Fan Control Over Temp Protect RTH1 or RTH2 50 C Fan On 45 C Fan Off 70 C Output Shutdown Temp Coefficient 0 03 C 0 50 C Setup Rise Hold up Time 1 5s...

Страница 39: ...Line Regulation 1 DC Output Power 275W Efficiency 78 2 typical at full load 230VAC Input Voltage Range 100 240 VAC full range with 10 tolerance AC Current 4A 115V 2A 230V Power Factor Correction 95 9...

Страница 40: ...CPU Part number Intel Core 2 Duo E7400 2 8Ghz 3Mb Cache 1066 FSB Dual Core Processor 775 Socket Memory Specification 2GB DDR2 SDRAM 240 pin DIMM 1 8V Supplier Dabs Disk Drive Solid state Specificatio...

Страница 41: ...s must be made In particular consideration must be given to the stability of free standing racks by mounting heavy equipment low in the rack The rear of the unit should be supported in the rack Power...

Страница 42: ...ards Declared EN 50081 1 EN 50082 1 Manufacturer s Name Television Systems Ltd Manufacturer s Address Vanwall Road Maidenhead SL6 4UB England United Kingdom Type of Equipment UMD System Controller Mod...

Страница 43: ...e 44 0 1628 564610 and ask for Technical Support who will assist in diagnosing the fault and will provide a Returns Number RMA This will enable us to track the unit effectively and will provide some i...

Отзывы: