AMU2-BHD+-6
15
ISSUE 6
3.7
Configuration Switch Functions (from S/W Release X06)
A)
SWITCH SECTION
FUNCTION
1
Not Used
2
Not Used
3
Speaker Mute Up
4
Digital Settings (see table below)
5
Digital Settings (see table below)
6
Digital Settings (see table below)
7
Not Used
8
Composite out-Up/SDI /Down
B)
SW4
SW5
SW6
FUNCTION
UP
UP
DN
-24dBFS
DN
UP
DN
-22dBFS
UP
DN
DN
-20dBFS
DN
DN
DN
-18dBFS
UP
UP
UP
-15dBFS
DN
UP
UP
TBD
UP
DN
UP
TBD
DN
DN
UP
TBD
4.0
LS Output
This is a bridged amplifier therefore neither terminal should be grounded.
5.0
Notes
0 dBm = 0.775V into 600
Ω
i.e. 1mW power dissipation.
0 dBu = 0.775V rms = PPM 4.
Nominally, -18 dB ref 0FS = 0 dBu output.
European line-up: -18 dBu
American line-up: -20 dBu
The LF Adjust potentiometer is non functional.
All audio monitoring Calibration procedures are factory Set.