The  following  table  shows  the  different  product  configurations  (Model  Numbers)  that  are 
available in the ATS-800 Series. The tables show models that are ETL listed and models that 
carry the CE mark. Each model number is comprised of the 800 Family Identifier followed by a 
four digit suffix, which signifies the Model configuration. These model configurations relate to the 
amps, voltage, frequency, input and output type and cord descriptive information that comprises 
the product to be ordered. For example: 

Part # ATS-800-2003 

is a 15 A, 120 V, 50/ 60 Hz, ATS-

800 unit with L5-15P (JP00055) input Plug and L5-15R output Receptacle and 6 foot long Cord 
(WI40302). 

 

ATS-800 Series Configuration 

TSi P/N 

Amps 

Voltage 
options 

Freq. 

options 

Input type 

Output type 

Cord 

ATS-800-2000 

15 

120 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001 

N/A 

ATS-800-2002 

15 

120 V 

50/60 Hz 

5-15P (WD00006) 

5-15R (JP00155) 

6

’ 

ATS-800-2003 

15 

120 V 

50/60 Hz 

L5-15P (JP00055 

L5-15R (JP00056) 

6

’ 

(WI40302) 

ATS-800-2004 

15 

120 V 

50/60 Hz 

IEC320 C-14 (JP00015) 

IEC320 C-13 (JP00101) 

Optional   

ATS-800-3000 

15 

220 V, 240 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001) 

N/A 

ATS-800-3002 

15 

220 V, 240 V 

50/60 Hz 

6-15P (JP00042) 

6-15R (JP00043) 

6

’ 

(WI40302) 

ATS-800-3003 

15 

220 V, 240 V 

50/60 Hz 

L6-15P (JP00046) 

L6-15R (JP00059) 

6

’ 

(WI40302) 

ATS-800-3004 

15 

220 V, 240 V 

50/60 Hz 

IEC320 C-14 (JP00015) 

IEC320 C-13 (JP00101) 

Optional 

ATS-800-3011 

15 

220 V, 240 V 

50/60 Hz 

Hardwire (JP00001)  

IEC320 C-13 (JP00101) 

N/A 

ATS-800-3800 

15 

208 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001) 

N/A 

ATS-800-3802 

15 

208 V 

50/60 HZ 

6-15P (JP00042) 

6-15R 9JP00043) 

6

’ 

(WI40302) 

ATS-800-3803 

15 

208 V 

50/60 Hz 

L6-15P (JP00046) 

6-15R (JP00059) 

6

’ 

(WI40302) 

ATS-800-3804 

15 

208 V 

50/60 Hz 

IEC320 C-14 (JP00015) 

IEC320 C-13 (JP00101) 

Optional 

ATS-800-3811 

15 

208 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001) 

N/A 

TSi P/N 

Amps 

Voltage 
options 

Freq. 

options 

Input type 

Output type 

Cord 

ATS-800-3900 

15 

230 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001)    

N/A 

ATS-800-3904 

15 

230 V 

50/60 Hz 

IEC320 C-14 (JP00015) 

IEC320 C-13 (JP00101 

Optional 

ATS-800-4000 

20 

120 V 

50/60 Hz 

Hardwire JP00001) 

Hardwire (JP00001) 

NA 

ATS-800-4002 

20 

120 V 

50/60 Hz 

5-20P (JP00027) 

5-20R (JP00090) 

6

’ 

(WI40301) 

ATS-800-4004 

20 

120 V 

50/60 HZ 

IEC60320 C-20 

(JP00100) 

IEC60320 C-19 

(JP00121)          

Optional 

ATS-800-5000 

20 

220 V, 240 V 

50/60 Hz 

Hardwire (JP00001) 

Hardwire (JP00001) 

N/A 

ATS-800-5002 

20 

220 V, 240 V 

50/60 Hz 

6-20P (JP00025) 

6-20R (JP00039) 

6’ 

(WI40301) 

Содержание ATS-00-500x

Страница 1: ...MC80047 Hardwire 208 V 800 3800 5800 7800 and 9800 15 20 30 40 A 220 240 V 800 3000 5000 7000 and 9000 15 20 30 40 A MC80048 Hardwire 230 V 800 3900 5900 7900 and 9900 15 20 30 40 A MC80049 Hardwire...

Страница 2: ...12 2 2 ATS Circuit Boards 12 2 3 Input Output Circuit Breakers 16 2 4 Audible Alarm Switch 16 3 INSTALLATION 16 3 1 Site Selection Preparation 16 3 2 Required Tools 17 3 3 Unpacking Inspection 17 3 4...

Страница 3: ...tic Transfer Switches Rev 3 April 2018 TSi Power Corporation Proprietary Information 3 5 3 Inventory Recommendations for Customer w Large Numbers of ATS Units 22 6 REFERENCE 23 6 1 Specifications 23 6...

Страница 4: ...valent to TSi or its authorized agent accompanied by a written receipt showing the date of purchase and both the model name and serial number of the product Warranty does not cover transportation cost...

Страница 5: ...phase power sources which allows them to be used with a number of different sources Customers with special requirements can be offered custom programming to address special use situations The ATS is f...

Страница 6: ...nt to make users aware of important operating and safety concerns NOTE Specific models of the ATS Series may be ETL Listed to signify conformance with UL CSA or CE requirements For actual Listings see...

Страница 7: ...unit The ATS allows redundant AC power to mission critical equipment using any combination of UPS backup generator or other available autonomous AC power sources Sturdy steel enclosure can be front ra...

Страница 8: ...e for servicing 1 6 REAR ACCESS See Figures 4 5 6 7 AND 8 The DB 9 Connector Primary and Backup circuit breakers Hardwire Termination compartments and Plugs and Receptacles are accessed from the rear...

Страница 9: ...ary Input AC Output 1 62 REAR VIEW OF MC80043 UNIT WITH HARDWIRE INPUT AND OUTPUT CONNECTIONS COVER See Figure 5 Figure 5 Rear view of ATS 800 6000 Hardwire unit showing DB9 connector Primary and Back...

Страница 10: ...our IEC60320 C13 AC Output Receptacles 1 7 COMPONENT LOCATIONS 1 71 TOP VIEW WITH COVER REMOVED See Figure 8 Removing the top cover exposes the main wiring and major components of the ATS Series Befor...

Страница 11: ...800 with top cover removed Primary AC Input Compartment Backup 15 A 20 A 30 A or 40 A Circuit Breaker Compartment Cover Mounting Holes Primary 15 A 20 A 30 A or 40 A Circuit Breaker AC Output Compart...

Страница 12: ...TS 800 System Architecture 2 2 ATS SERIES CIRCUIT BOARDS 2 21 Main Control Circuit Board Assemblies See Figures 10 and 11 Two main control circuit boards are used in the ATS Series The PZ00120 5 is us...

Страница 13: ...roprietary Information 13 Figure 10 PZ00120 5 Main Control Circuit Board Assembly for ATS 800 2000 3000 4000 5000 6000 and 7000 models Circuit Board Mounting Holes for Snap On Standoffs Circuit Board...

Страница 14: ...anel of the ATS housing and attached by means of a ribbon cable and connector to the main control board These LEDs as shown in Figure 3 and 12 signify the following Green Primary LED ON indicates Prim...

Страница 15: ...ts are outlined in section 4 3 Figure 13 PZ00129 DB 9 Alarm Circuit Board Assembly 2 3 INPUT OUTPUT CIRCUIT BREAKERS See Figure 13 One two pole circuit breaker located in the rear of the unit connects...

Страница 16: ...r Figure 14 Primary Backup Type AC Input Two Pole Circuit Breakers 15 20 30 40 A 2 4 AUDIBLE ALARM SWITCH See Figure 15 Figure 15 P N SE00002 Audible Alarm On Off Switch 3 INSTALLATION 3 1 SITE SELECT...

Страница 17: ...TION 3 31 The units are shipped in individual cartons and may come stacked on wooden pallets depending on the size of the order In this configuration the units are placed on the pallet with protective...

Страница 18: ...narily intended for use in a stacked configuration with other ATS 800 units although this can be done with care In the event a stacked installation is planned please contact TSi Power for assistance 3...

Страница 19: ...ed screwdriver terminate the incoming backup wires on the terminal blocks behind the rear cover marked Backup Input These terminals are marked as follows LI for backup input line or L1in for backup in...

Страница 20: ...input frequency is within 5 of that specified Both primary and backup must be the same nominal frequency 2 Turn on the Backup AC circuit breaker in the rear of the ATS unit Make sure that the audible...

Страница 21: ...Status DB 9 Pins are _5__NO _1__NC__2_COM Backup AC Input Status DB 9 Pins are _6__NO _3__NC _4__COM 4 32 When Primary AC Input is present and IN SPECIFICATION there is an OPEN circuit between pin_5...

Страница 22: ...oard assembly for ATS 800 2000 3 4 5 6 or 7000 models Customer must provide voltage amperage Frequency options PZ00127 5 Main Control Board assembly for ATS 800 8000 or 9000 and 9900 models Customer m...

Страница 23: ...Hz or 9 7 ms for 50 Hz Input output wire size 14 AWG 2 08 mm 12 AWG 3 3 mm 10 AWG 5 26 mm 8 AWG 8 36 mm AC input and output connections Hardwire terminals standard Hardwired units must be installed b...

Страница 24: ...ther configurations available O U TP U T Voltage C urrent 120 V 15 20 A Load regulation 1 from no load to full load P ow er efficiency 99 or higher R eceptacle m odels 2002 2003 2004 R eceptacle m ode...

Страница 25: ...e same nominal frequency Transfer time Typically cycle 8 ms for 60 Hz or 9 7 ms for 50 Hz AC input connections IEC60320 C 14 IEC60320 C 20 OUTPUT OUTPUT OUTPUT OUTPUT Voltage Current 230 V 15 20 A Loa...

Страница 26: ...2 0 P L6 2 0 P IE C 6 0 3 2 0 C 2 0 O ther co nfig uratio ns availab le O U T P U T V o ltag e C urrent 2 0 8 V 1 5 2 0 A 2 2 0 V 2 4 0 V 1 5 2 0 A Lo ad reg ulatio n 1 fro m no lo ad to full lo ad P...

Страница 27: ...m e Typically cycle 8 m s for 60 Hz or 9 7 m s for 50 Hz AC input connections Hardwire term inals standard Hardwired units m ust be installed by a qualified electrician OUTPUT Voltage Current 208 V 15...

Страница 28: ...lly cycle 8 ms for 60 Hz or 9 7 ms for 50 Hz AC input and output connections Hardwire terminals standard Hardwired units must be installed by a qualified electrician OUTPUT Voltage Current 230 V 15 20...

Страница 29: ...9 7 ms for 50 Hz AC input connections Hardwire terminals standard Hardwired units must be installed by a qualified electrician OUTPUT Voltage Current 208 V 15 20 30 or 40 A 220 or 240 V 15 20 30 or 4...

Страница 30: ...cycle 8 ms for 60 Hz or 9 7 ms for 50 Hz AC input connections Hardwire terminals standard Hardwired units must be installed by a qualified electrician OUTPUT Voltage Current 230 V 15 A 230 V 20 A Load...

Страница 31: ...015 IEC320 C 13 JP00101 Optional ATS 800 3000 15 220 V 240 V 50 60 Hz Hardwire JP00001 Hardwire JP00001 N A ATS 800 3002 15 220 V 240 V 50 60 Hz 6 15P JP00042 6 15R JP00043 6 WI40302 ATS 800 3003 15 2...

Страница 32: ...IEC60320 C 20 JP00100 IEC60320 C 19 JP00121 Optional ATS 800 6000 30 120 V 50 60 Hz Hardwire JP00001 Hardwire JP00001 N A ATS 800 7000 30 220 V 240 V 50 60 Hz Hardwire JP00001 Hardwire JP00001 N A AT...

Отзывы: