TScale BW Series Скачать руководство пользователя страница 20

BW / CW/VW/BWS Series Indicator Technical Manual 

 

- 19 - 

-QTY UNIT-

 

 

8. RS-232 OUTPUT 

 

 

8.1. Specifications:  

 

RS-232 output of weighing data 
Code             :  ASCII 
Data bits       :  8 data bits 
Parity             :No Parity 
Baud rate      : 600bps to 9600bps selectable 

 

8.2. Connecter:  
 
RS-232 Output 

                    
                     

Pin 2:   Input 

                     Pin 3:   Out put 
                     Pin 5:   Signal Ground 
 

Check Weighing Output 

 
                    Pin 1 : VB 
                    Pin 4: Vcc 5v (Output) 
                    Pin 5: Com (Ground) 
                    Pin 6: Ok (Output) 
                    Pin 7: Low (Output) 
                    Pin 8: Hi (Output) 
                    Pin 9: Beep (Output) 
 

8. 3. Continuously output protocol 
 

Con1

Weighing mode

 

 

g  CR  LF 

-HEADER1--        - HEADER2-                       ---  WEIGHT  DATA  --                                            

 

         

Counting mode 

 

s  CR  LF 

 
HEADER1: ST=STABLE

 US=UNSTABLE 

HEADER2: NT=NET

 GS=GROSS 

-WEIGHT UNIT-  TERMINATOR 

 

- QTY - 

Содержание BW Series

Страница 1: ...WEIGHING INDICATOR TECHNICAL manual ...

Страница 2: ...iga net tw W P Scales Mfg Kunshan Co Ltd No 99 Shunchang Road Zhoushi Kunshan Jiangsu China TEL 86 512 57669080 FAX 86 512 57669100 e mail sales taiwanscale com Copyright by Taiwan Scale Mfg Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Taiwan scale Taiwan Scale reserves the right to make changes to...

Страница 3: ...3 Tare 10 4 Select Unit 10 Check Weighing 11 Set Limits 1 1 Set Check W eighing 1 1 Accumulation 12 Memory Recall 1 2 Memory Clear 1 2 Automatically Accumulation 12 Parts Counting 13 Animal Weighing 13 Key Board Lock 14 Set Auto Power Off 14 Set Back Light 14 6 PARAMETERS 16 7 CALIBRATION 18 8 RS 232 OUTPUT 19 Specifications 19 Connecter 19 RS 232 Output 19 Check weighing Output 19 Continues outpu...

Страница 4: ...BS Plastic SST Operating Temperature 10 C 40 C 14 F 104 F Resolution 1 6000 OIML Approved Key Pad 7 Keys Power AC Adaptor 12V 500mA Battery 6V 4Ah Calibration Automatic External Interface RS 232 Output Optional Load cell drive Voltage Max 5V 150mA Load Cells Up to 4 load cell ADC Sigma Delta ADC Update 1 10 second Stabilization Time One seconds typical ...

Страница 5: ...signals from a load cell converts it to digital data and displays it as a mass value It is suitable for general weighing or more specialized applications such as check weighing animal weighing and accumulation applications It can connect the indicator to a printer or a PC Large LCD with white LED back light or LED displays ...

Страница 6: ...e and receptacle type are correct for the scale Only use original adaptor other could cause damage to the scale Pluggable equipment must be installed near an easily accessible socket outlet Avoid unstable power sources Do not use near large users of electricity such as welding equipment or large motors Avoid sudden temperature changes vibration wind and water Avoid heavy RF noise Keep the indicato...

Страница 7: ...ct Turn on the On Off key If you want to turn off press the key again Display will be show the scale capacity and will be starting self checking After self checking display will be come to normal weighing mode Warm up time of 15 minutes stabilizes the measured values after switching on Calibrate with exact calibration weights minimum 1 3 of the scale capacity want to use for calibration For calibr...

Страница 8: ...d there is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be recharged If the LED is green the battery has a full charge If it is red the battery is nearly discharged and if yellow the battery is being charged Do not use any other type of power adaptor than the one supplied with the scale Verify that the AC power socket ou...

Страница 9: ...on Power turn ON OFF Set the Zero Display To perform a tare function Subtracts weights Memory recall key show the stored values from the memory Accumulator key current values will store to the memory To send the data to printer or PC Shift to Gross Net Weight To change Unit hold three seconds ...

Страница 10: ...of the keys Function Keys To confirm the selected menu To change the menu and active digit To move the active digit to right To move the active digit to left To enter in to the menu Escape from the menu to normal operation Display Battery low Check Weighing Weighing unit ...

Страница 11: ...f your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero 3 Tare The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed Load weight on the platform Press key Zero is displayed and tare is subtracted Remove weight on the platform Tared weight is displayed ...

Страница 12: ... the high limit value by using and keys to change the active digits and press key to increment the value Press key to confirm display will show set l Enter the high limit value by using and keys to change the active digits and press key to increment the value Press key to confirm To escape from the settings press key 5 2 2 Set Check Weighing Press and key together display will be show set h Press ...

Страница 13: ...ication Display will be show acc 1 then will be show the total saved value These displays will be shown only three seconds Remove the weight from the pan When display get zero and stable then place the second weight It can continue until the memory gets fully or 99 items 5 3 1 Memory Recall To recall the memory press key Display will be show acc X X Total number of accumulation then will be show t...

Страница 14: ...s Counting Operation Select the parts quantity as per the option Place the load on the platform Press key to confirm display will be shown then will show the quantity Then can add goods on the platform display will update the parts quantiity automatically Press key to change normal mode when in counting mode 5 5 Animal Weighing BW BWS VW can use for vibrate loads weigh This function can use for an...

Страница 15: ...uto power off It can set auto power of the scale when scale not in use scale will turn off after the setting time Hold key three seconds display will show setbl Press key to change Set of and press key to confirm Press key to change the options Set of Of 0 To set auto off function turn off for scale always on Of 3 Set to turn off three minutes later Of 5 Set to turn off five minutes later Of 10 Se...

Страница 16: ...ight will be on and when stop the operation back light also will off Bl on To set always on After turn on the power back light also will be on Bl off To set back light turn off No back light in the operations After select the back light option press key to confirm and press key to escape from the settings ...

Страница 17: ...tween the limits ng Beep when check weighing out of the limits P 1 com Mode This option is used to set accumulation and RS 232 communication Options Cont data send continues St 1 Send data one time when stable St c Send data continuously when stable P r1 Send data one time when press print Key in printer mode Pr 2 Send data to print and accumulation When press key Auto Auto accumulate and auto pri...

Страница 18: ...s 1 2 5 10 20 50 100 200 R1 cap To set the scale capacity On R1 inc To select the scale division Options 1 2 5 10 20 50 100 200 R1 cap To set the scale capacity Then press to set R2inc and R2 cap Cal To set non linear calibration Count Showing scale internal counts gra To set local gravity P4 oth Lock To set keypad lock Options on off anm To set animal mode Options on off Note Du al This function ...

Страница 19: ...ss key to enter calibration display will be show unld Remove all the weight from the platform When indicator get stable press key to confirm Display will be show the last calibration weight If want to change the calibration weight value press and keys to change the active digits and press key to increment the value When the calibration value is correct press key to confirm Display will be show loa...

Страница 20: ...e 8 2 Connecter RS 232 Output Pin 2 Input Pin 3 Out put Pin 5 Signal Ground Check Weighing Output Pin 1 VB Pin 4 Vcc 5v Output Pin 5 Com Ground Pin 6 Ok Output Pin 7 Low Output Pin 8 Hi Output Pin 9 Beep Output 8 3 Continuously output protocol Con1 Weighing mode k g CR LF HEADER1 HEADER2 WEIGHT DATA Counting mode P C S p c s CR LF HEADER1 ST STABLE US UNSTABLE HEADER2 NT NET GS GROSS WEIGHT UNIT T...

Страница 21: ...ross weight header2 header2 02H If overload or gross weight header2 header2 04H If unstable header2 header2 08H If weighing unit kg header2 header2 10H Header3 follow weighing unit If weighing unit g header3 21H If weighing unit oz header3 23H Weight1 weight6 weighing data Tare1 tare6 tare value Terminator1 0DH Terminator2 0AH Con3 Header 0 Header 1 Weight 1 Weight 2 Weight 3 Weight 4 Weight 5 Wei...

Страница 22: ...ty Err 5 Key board error Check the keys and connecter Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Check the load cell and connecters Err 17 Tare out of range Remove the load and restart scale again ol Over range Remove the load Re ...

Страница 23: ...BW CW VW BWS Series Indicator Technical Manual 22 12 DRAWING 12 1 BW CW VW Drawing ...

Страница 24: ...asher 3 8x3 1x1 5t optional 9 RS 232 PCBA 1 0ptional 10 Seal Ring 1 11 Screw Column 3 5 8x3 8x10H Optional 12 Analog Output PCBA 1 13 Nut 3 M3 Hexagon 14 Self Thread Star Screw 2 4x10 15 Washer 2 9x4 4x0 8t 16 Battery bar 1 17 Battery 1 6V 4Ah 18 Spacer 2 Optional 19 Back Cover 1 ABS 20 Self Thread Star Screw 6 4x116 21 AC Adaptor Jack 1 22 Air Connecter 1 5Pin For load cell 23 Air Connecter 1 9Pi...

Страница 25: ...BW CW VW BWS Series Indicator Technical Manual 24 12 3 BWS Drawing ...

Страница 26: ...f Rubber Bar 1 9 Star Screw 2 M4x10 10 Washer 2 M4 11 Battery Clamp 1 12 Washer 6 M4 13 Star Big head Screw 6 M4x12 14 Bracket 1 15 Bracket Screw 2 16 Water Proof Adaptor jack 1 17 Interface Module 1 18 Air connecter 1 5Pin 19 Plug 1 20 Rubber Spacer 3 21 Air Connecter 1 7Pin 22 Back Cover 1 23 Air Connecter Water Proof Nut 1 24 Battery 1 6V 4Ah 25 Nut 1 M3x6 26 Main Serial board 1 27 Spacer 1 28 ...

Отзывы: