46
B. Bline Mode
Press the
and
buttons to scroll the cursor to the sensor type. Press
the
button to enter the black-mark sensor calibration mode.
B-1 Automatic
When enter the [Automatic] option, you will see following message
and
printer will feed the black mark label to calibrate the sensor sensitivity
automatically. When calibration process is completed, the LCD screen will
return to the previous menu.
B-2 Manual
In case
“Automatic” sensor calibration cannot apply to the media, please
use “Manual” function to calibrate the bline sensor manually.
When enter [Manual] option, you will see following message. Please
complete there steps
:
Paper Len.
00151 dot
1. Press the
button to move the
cursor from left digit to right digit, and press
the
button to set the value from
“0” to
“9” and the “dot/ mm/ inch”. Press the
button to set the paper length into
the printer.
Bline Size
0024 dot
2. Press the
button to move the
cursor from left digit to right digit, and press
the
button to set the value from
“0” to
“9” and the “dot/ mm/ inch”. Press the
button to set the bline size into the
printer.
Calibration 2/4
Gap Mode
>
Bline Mode
Cont. Mode
Bline Mode 1/4
>
Automatic
Manual
Pre-Printed
Bline Mode
Automatic
Bline Mode 2/4
Automatic
>
Manual
Pre-Printed