background image

11

Notes: 

 

While  exchanging  data  with  the  computer  using  the 

RecManager program, do not turn off the module at this time due 

to possible loss of data. 

When the module is connected to a PC, audio recording is im-

possible. When audio recording is turned on, the connection to 

a PC is impossible.

 

  

The program manual has full information about the RecManager 

program.  The  software  manual  is  on  the  supplied  CD  (/Edic-

MiniTiny/).

Our company’s support engineers constantly at work to improve 

our software and the documentation.  You can always download 

a new version of our software and documentation for free from 

our website: http://ts-market.com . 

To Renew Firmware

 

To renew the firmware of your module, go to the website http://ts-

market.com . Follow these steps:

• Download the new firmware from the website to a PC: ET_

FW_Updater_X_X.exe (X_X is the number of a version of 

the firmware)

• Connect  the module to the PC

• Check that the RecManager program is closed. 

• Run the new firmware

• Confirm that you want to renew the firmware

Содержание EMM Tiny Module

Страница 1: ...EMM Tiny Module Operation manual Version 06 10 15 TS Market ...

Страница 2: ...eristic 5 Working with the Module 7 Preparing for Work 7 Choosing the Recording Parameters 8 Default Settings 8 Voice Recording 9 Playing the Recordings 10 Connecting to a PC 10 To Renew Firmware 11 Multilingual Support 12 Troubleshooting 13 Support 15 ...

Страница 3: ...ction in challenging environment at wide temperature range dustiness or shaking Using the supplied USB cable the module can be connected to a computer The supplied software works with Windows 2000 XP and allows storing audio recordings as standard audio files and programming module s parameters The module can work in a flash disk mode with memory capacity depending on modifica tion from 128 MB up ...

Страница 4: ...sed for storing and trans ferring any type of data The module can function as a flash me dia and voice recorder simultaneously Distribution of memory space is assigned by the user Password protection provides security of audio recordings and the module s settings In addition every recording has a digi tal watermark containing date and time of the recording along with the module s identification da...

Страница 5: ...PCM 2 and 4 bits Sampling rate 5 5 8 11 16 or 22 kHz Frequency band Up to 100 10k Hz depend ing on settings Input signal 2 9 Vpp with constant 1 5 V Consumption current 3 0 2V Consumption current in stand by mode Not more 25 microA Supply voltage recording in mono mode without com pression 2 mA Design PCB PC interface USB 1 1 transfer rate up to 5 5 Mbps ...

Страница 6: ...its sec k 6 9 Without compression linear sampling rate 8 kHz 80 kbits sec k 5 Without compression linear sampling rate 5 5 kHz 55 kbits sec k 3 4 Logarithmic compression u Law sampling rate 22 kHz 176 kbits sec k 11 2 Logarithmic compression u Law sampling rate 16 kHz 128 kbits sec k 8 Logarithmic compression u Law sampling rate 11 kHz 88 kbits sec k 5 6 Logarithmic compression u Law sampling rate...

Страница 7: ...g mode is changed For instance maximum recording time 1120 modification without compression sampling rate 8 kHz k 5 is 1120 5 224 minutes Sampling rate defines the recorded frequency band that is lightly less than a half of the chosen sampling rate The best recording quality is in a mode without compression then as the quality decreases Logarithmic 4 bit ADPCM and 2 bit ADPCM In addition modes wit...

Страница 8: ...hree times showing that the module has started self testing After 5 10 seconds the indicator will blink for the fourth time the length of the fourth flash depends on the module s memory capacity and can be some dozens of seconds After this the module is ready for work To provide a reliable start it is recommended to make a pause for 30 60 seconds between turning the module off and on Choosing the ...

Страница 9: ... of supply voltage and memory capacity The first sequence of flashes 1 3 flashes shows the level of supply voltage and the second sequence shows free memory capacity see the manual s appendix for additional information 4 flashes 0 25 3 flashes 25 50 2 flashes 50 75 and 1 flash 75 100 The sequences are going with 1 5 sec intervals the sequences are repeated during a period of 6 sec Pay attention th...

Страница 10: ...pplied USB cable The module LED will light If it is the first time connect ing OS Windows will suggest installing the drivers Follow the instructions in the Automatic Installation dialog windows of the Installation Wizard While installing this message can appear The installed software has not been tested for compatibility with Windows XP Click Continue Start the RecManager program If the program i...

Страница 11: ... Edic MiniTiny Our company s support engineers constantly at work to improve our software and the documentation You can always download a new version of our software and documentation for free from our website http ts market com To Renew Firmware To renew the firmware of your module go to the website http ts market com Follow these steps Download the new firmware from the website to a PC ET_ FW_Up...

Страница 12: ...dicTi ny_rus lng and RecManager_rus lng files in Program Files RecManager folder On the first line of the file change the number of the code page according to your preferred language Translate all signs and messages from English Russian into your language Rename files EdicTiny_XXX lng and RecManager_XXX lng XXX abbreviating of a new language expressed by the English alphabet After running the RecM...

Страница 13: ...he switch was set in the RECORD position 1 Power sup ply is not connected 2 The mod ule was not turned on 1 Check the connection to power source 2 Disconnect and after 50 60 sec connect module s power supply The indicator flashes 10 times in sequences 1 the module was not turned on 2 Memory error 1 Disconnect and after 50 60 sec connect module s power supply 2 Contact to the technical support serv...

Страница 14: ...in sequenc es Power voltage is low Check the power source The indicator flashes continu ously There is not enough memory space for recording Free memory space delete useless record ings or and reduce flash memory space Can t con nect the module to a PC The indicator lights OS Windows can t download the drivers See Connecting to a PC or contact to the technical support service ...

Страница 15: ...ation download the new one from http ts market com If the errors are not elimi nated connect to our technical support service support ts mar ket com We will eliminate the errors as soon as possible Also we will appreciate the detailed information about the errors ...