Страница 2: ...TERMINAL BOARD DESCRIPTION 5 CONNECTION WITH EXTERNALLY POWERED ENCODER 6 CONNECTION WITH SELF POWERED HALL SENSOR 6 OUTPUTS CONNECTION WITH NPN LOGIC 6 AC OUTPUTS CONNECTION 6 USE 7 KEYBOARD DESCRIPTION 7 SETUP PROCEDURE 7 WORKING PARAMETERS SETTING 9 WORKING DIAGRAM 10 ERROR MESSAGES 11 WARRANTY 11 ...
Страница 3: ... to read carefully the following instructions Entity Elettronica does not assume any responsibility for injuries or damages for persons or things deriving from non compliance with the instructions in this manual It does not assume any responsibility for eventual inaccuracy and reserves the right to modify partially or totally the device features and documentation Technical data in this manual incl...
Страница 4: ...P62 device mounted on a panel Weight 370 gr Keyboard Vetronite covered with Scratch resistant polycarbonate Operating Temperature 0 40 C Transport and storage temperature 25 70 C Operating Humidity 90 MECHANICAL MOUNTING MECHANICAL MOUNTING MECHANICAL MOUNTING MECHANICAL MOUNTING This device container has been designed for panel mounting make an hole as described in the picture at the bottom of th...
Страница 5: ...te voltage 0V 6V 1 logic state voltage 10V 12V Digital outputs Opto insulation 2500 V rms Commutable load AC DC NPN PNP Maximum operating tension 40 Vac dc Maximum current 500 mA Connect only one conductor for each terminal and be sure that the power supply is as indicated on the back of the device use only cables properly insulated for operating tensions and temperature keep power cables separate...
Страница 6: ...ION WITH SELF CONNECTION WITH SELF CONNECTION WITH SELF CONNECTION WITH SELF POWERED POWERED POWERED POWERED HALL SENSOR HALL SENSOR HALL SENSOR HALL SENSOR OUTPUTS CONNECTION W OUTPUTS CONNECTION W OUTPUTS CONNECTION W OUTPUTS CONNECTION WITH NPN LOGIC ITH NPN LOGIC ITH NPN LOGIC ITH NPN LOGIC AC OUTPUTS CONN AC OUTPUTS CONN AC OUTPUTS CONN AC OUTPUTS CONNECTION ECTION ECTION ECTION ...
Страница 7: ... SETUP PROCEDURE SETUP PROCEDURE SETUP PROCEDURE SETUP PROCEDURE Description Display To start setup mode push L00 will flash on the display Enter 99 with arrow keys confirm with C00 will flash on the display Insert the parameter code and then push On the display will appear the value of the chosen parameter Change the value with arrows keys as desired and confirm with the value will not be accepte...
Страница 8: ...99999 OUT 1 logic 0 Positive logic 1 Negative logic 2 Positive pulse 3 Negative pulse Timer OUT 1 from 00 00 to 99 99 seconds if 0 or 1 the set value delays OUT 1 activation if 2 o 3 the set value is the pulse duration OUT 2 logic 0 Positive logic 1 Negative logic 2 Positive pulse 3 Negative pulse Timer OUT 2 from 00 00 to 99 99 seconds if 0 or 1 the set value delays OUT 1 activation if 2 o 3 the ...
Страница 9: ... the chosen parameter will appear Change the value with arrow keys and confirm with The value of the next parameter will appear To continue working parameters setup push To exit from setup mode push twice Parameter code Function Range and allowed values Notes Firs threshold from 000000 to 999999 Second threshold from 000000 to 999999 Setup code Start the setup mode Prefix meaning Measured value is...
Страница 10: ... as measured value gets greater than set threshold and continues to be activated until the measured value gets lower than it pic A if and s values are set to 2 or 3 output will activate as soon as measured value gets greater than set threshold stays activated for as many seconds as they are set with or and then it is turned off even if measured value is still behind threshold one pic B ...
Страница 11: ...lained above Flashing display measured value exceeds the maximum visualizable value WARRANTY WARRANTY WARRANTY WARRANTY The device is guarantee against construction vices or defected materials noticed within 12 months from delivery date The opening of the housing of the instrument the wrong use and bad installation due to non observance of the indications of this manual means the automatic decay o...
Страница 12: ...s two outputs signals Counter It shows incremental counting compares the value with two setpoints and provides two outputs signals Single axis positioner It shows single axis level compares measured value with one setpoint and provides four output signals The marking of single components does not assure that final product is compliant with the norm and does not free the producer from law duties on...