4
SPECIFICATIONS:
Voltage/frequency:
230 V~ 50 Hz
Power
550 W
Maximum delivery
10500 l/h
Maximum head
7 m
8 m
Maximum submersion depth
Maximum water temperature
º
+35 C
Max. solids diameter
25/35 mm
Net/gross weight
4,8/5,25 kg
Suction hose diameter
10 mm
1100 W
15000 l/h
9,5 m
5,75/6,22 kg
MODEL
TPB1102
TPB5502
Power cord length
10 m
Fixed pipeline connection diameter
35/45 mm
Motor
Single-phase, asynchronous
DELIVERY CURVES DURING OPERATATION UP TO THE PUMPING HEIGHT OF:
H/m
9
6
3
0
12
3000
6000
9000 12000 15000 l/h
TPB5502
H/m
9
6
3
0
12
3500
7000
10500 14000 17500 l/h
TPB1102
INSTALLATION:
not carry it by its power cord!
During installation the pump cannot be connected
- If the ground the pump is placed on is unstable, it is recommended to
to its power source.
suspend it by its handle or carry out a firm platform to protect the inlet
against clogging.
It is absolutely prohibited to touch the pump
opening when the pump is connected to a power source.
- If water handled contains fibrous contaminations (grass, leaves),
place the pump in the basket.
- The compact construction of our submersible pump facilitates its
operation and site installation. The pump can be installed in: a fixed
- The system should be adjusted depending on actual needs, it is
system - with a fixed pipeline, or in a mobile mode - using a flexible
recommended to install a non-return ball valve.
hose. The float switch (
5
) allows for an automatic mode. The pump
- Non-return valves should be installed in the upper part of the system.
should work as partly or completely submerged in liquid it carries.
- When installing the pump in the open, pump lines, valves, electrical
Tip!
accessories (terminal boxes) should be protected against freezing.
The reservoir where the pump is supposed to be placed should have the
CONNECTING TO THE POWER SOURCE:
following dimensions: at least 60x60x60 cm to provide space for the
The pump is equipped with a PE pin plug. It should be connected to an
float switch to move freely.
AC socket 230 V 50 Hz equipped with a PE pin. Make sure that the AC
Figure
B
(p. 2) shows an example of fixed pump settings and the
socket circuit is fitted with a 10 A fuse (rated current) and it is in good
minimum tank dimensions for automatic operation as well as
condition. Insert the power cord plug into the AC power socket – thus
condition for turning it on/off by the float switch.
the pump becomes ready for operation.
- The pump lowers water level down to a few centimeters above the
Warning!
When the power cord or the plug is damaged as a result of
reservoir bottom and can continue operation in the case of continuous
external forces, do not repair it! The cable (power cord) must be
water inflow.
replaced.
- When the pump is set for mobile operation (see Fig.
C
), the pump
Note!
The cable (power cord) can be replaced by an authorized service
should be raised and lowered with a rope attached to the handle (
3
). Do
only. Contact the manufacturer.
Содержание TPB1102
Страница 2: ...1 A 1 3 4 6 7 8 B 5 10 2 600 x 600mm 110 mm 360 mm ON OFF 600 mm 9 5 11...
Страница 3: ...C 2 5 4 D...
Страница 17: ...16 1 230 n 5 360 B ON OFF 110 360 1 Ph2 11 9 n 2 360 mm 5 4 D 3 110 1 1 1 2 3 4 5 2 3 4 5...
Страница 27: ...26 5 1 230 60x60x60 5 B 2 360 B ON OFF 110 110 360 C 3 360 5 4 D 70 1 230 50 10 n n...
Страница 28: ...27 1 Ph2 11 9 2 3 5 1 2 3 4 I i 34 03 228 I...
Страница 39: ...TPB1102 TPB5502 38 n 6 30mA 11 3 35 C 6 10 9 5 3 6 2 1 max35 C 4 10pH 2 1 2 3 4...
Страница 41: ...40 4 D 110 1 230 V 50 Hz 10A 1 Ph2 1 11 9 230V 2 n 5 360 3 B ON OFF 110 360 n 360 5 1...
Страница 50: ...49...
Страница 51: ...50...
Страница 52: ...www profix com pl...