background image

 

13

Insert the TRP-Serial CD, find the ”Serial Server Admin Utility”. 

 

 

When Installation is completed the wizard creates a Serial Server Admin Utility shortcut on the 

Desktop as shown below. 

 

 

Double Click on the Serial Server Admin Utility then Right click on the main window or go to 

Server Manager in Menu Bar and select Search Devices to find the TRP-C34H on the network.     

 

By default all the devices searched are locked and can be seen under the status column of the 

Server Manager Window in order to protect from unauthorized configuration changes.   

In order to configure the device, it has to be Unlocked first. Unlock password: 

 trycom 

After the device has been Unlocked, the device can be configured for all Network, Serial, 

Operating settings. Select the device to be configured, Right Click on the selected device and 

click on configure to go to Configuration menu. (Double clicking on selected device can also 

open the Configuration menu).       

Содержание TRP-C34H

Страница 1: ... to change without prior notice in order to improve reliability design and function and dosed not represent a commitment on the part of the manufacturer No part of this manual may be reproduced copied or transmitted in any form without the prior written permission of manufacturer Acknowledgment Products mentioned in this manual are mentioned for identification purpose only Products manes appearing...

Страница 2: ... drivers that work with Operating Systems WIN 32bit XP Vista 2003Server 2008 Server 32 bit 64 bit 2000 Server OS Win 7 32 bit 64 bit The driver establishes a transparent connection between host and serial device by mapping the IP Port Number of the TRP C34H s Serial Port to a local COM Port on the host computer The important point is that Real COM Mode allows users to continue using RS 232 422 485...

Страница 3: ... Client and UDP using TCP IP and UDP protocols z Support Auto MDIX twisted pair crossover detection and auto correction z Low cost solution and easy to support 6 8 10 12 14 16 RS 232 422 485 Serial Ports z Each Port maximum connection 4 host PC at TCP Server and TCP Client Mode z External P1 P2 P3 USB port each port can connect TRP C08S C08U C08H C08X C29U z Maximum allowed bandwidth is 460 Kbps p...

Страница 4: ...P SNTP z External P1 P2 P3 Port each port can be connecting item below TRP C08S USB to 1 RS232 and 1 RS422 485 Isolated Converter TRP C08H USB to 2 RS232 and 2 RS422 485 Isolated Converter TRP C08U USB to 4 RS232 Isolated Converter TRP C08X USB to 4 RS232 422 485 Converter TRP C29U USB to 8 Digital Input and 8 Digital Output Remote I O z Power supply Screw terminal or standard external DC adapter ...

Страница 5: ...onnected to any of the P1 P2 P3 Ports of TRP C34H to support 8 12 16 Serial Port interfaces Each TRP C08X can provide four RS232 RS422 RS485 Serial Ports 1 4 TRP C34H Support TRP C08X C08S C08H C08U C29U Diagram TRP C08X TRP C08H TRP C08U TR C29U connected to any of the P1 P2 P3 USB Ports of TRP C34H to support 6 8 10 12 14 16 Serial Port interfaces or Maximum 24 Channel I O with TRP C29U ...

Страница 6: ... 2 Hardware Description 2 1 Panel layout and Dimension mm Unit Notice User can only choose either external DC Jack or Screw terminal DC input Do not use DC Jack and screw terminal DC input simultaneously ...

Страница 7: ...COMA COMD RS232 422 485 Transiting Receiving Indicator DC Jack Power Input DC 10V to 30V Pleas use the 5 5 2 1mm DC JACK 2 3 Factory default Push the factory restore button till the PWR LED off and then reboot Hardware Setting COMA COMD RS232 Unlock Password trycom Model Name SerialServer 4S Basic configuration IP setting ...

Страница 8: ...232 Operating Mode Real Com Mode Accessible IPs None Setting Auto Warning None Setting IP Address Report None Setting Password Factory trycom 2 4 DIP Switches There are 4 DIP switch allows the TRP C34H adjust to RS232 or RS422 485 Inside of the box ...

Страница 9: ...the switch to select RS232 or RS422 485 2 5 Push Button If lost the password or IP user can keep push button for restore factory default till the PWR LED off and then reboot 2 6 Four RS232 D SUB male PIN assignments 2 7 Four RS422 485 Screw Terminal assignments ...

Страница 10: ...up The TRP C34H Support Auto MDIX A straight through or crossover RJ45 cable can be used to make a connection directly to the HUB Router PC LAN port STEP4 Connect TRP C34H to RS232 device by Null Modem cable Connect TRP C34H to RS422 485 by AWG 12 30 twisted pair wires 3 1 RS485 Wiring The RS 485 mode supports the Transmit and Receive channels use twisted pair wire half duplex operation 3 2 RS422 ...

Страница 11: ...11 4 How to configure TRP C34H There are 3 ways to access the TRP C34H a Serial Server Admin Utility b WEB Server ...

Страница 12: ...12 c Telnet 4 1 Installing Serial Server Admin Utility The Serial Server Admin Utility Support WIN XP VISTA 2003 Server 2008 Server 32 64 bit 2000 Server Win 7 ...

Страница 13: ...work By default all the devices searched are locked and can be seen under the status column of the Server Manager Window in order to protect from unauthorized configuration changes In order to configure the device it has to be Unlocked first Unlock password trycom After the device has been Unlocked the device can be configured for all Network Serial Operating settings Select the device to be confi...

Страница 14: ...14 This invokes the Server Manager Configuration Dialog as shown below On Basic page check the Modify check Box to change any of the Configuration details IP Setting ...

Страница 15: ... to modify the parameter Static DHCP BOOTP e DNS Server 1 When the user wants to visit a particular website the computer asks the Domain Name System DNS Server for the website s correct IP address and the computer uses the response given by DNS Server to connect to the Web Server DNS is the way that Internet Domain Names are identified and translated into IP address ...

Страница 16: ...ngs Page On the Port Settings page of the Server Manager dialog displays all the serial ports present on the Serial Server model of the selected device It also shows the corresponding serial settings in the settings column of the page In order to see the current settings of any Serial port select the port number in above window then click on View settings To modify the serial settings check the mo...

Страница 17: ...al settings of that particular port change as per the Hyper terminal session opened Operating mode Click on Operating mode which opens the operating mode page as shown Select any port and click on View Settings tab which shows the Operating Mode dialog Box as shown below The default operating Mode is Real Com Mode Note TRP C34H will restart automatically after configuring the Operating Settings pa...

Страница 18: ...osed TRP C34H starts listening for another REAL COM driver s connection form another host TCP Server Mode a Local TCP Port The TCP Port of TRP C34H that uses to listen to the requests coming from Host Computers on Network in order to establish connection The Host Computers should contact this Port in order to establish connection with the TRP C34H b Click the Max Connection drop down box to set Ma...

Страница 19: ... Destination IP addresses 2 3 4 allows TRP C34H to connect actively to the remote hosts whose address is set by this parameter d TCP Alive Check Timeout Default setting is 7 min e Inactivity Timeout Default setting is 0 Disabled UDP Mode a Local Listen port The UDP port that uses to listen to Data from multiple host computers and also to multicast data to multiple host computers b UDP Mode Setting...

Страница 20: ...ss the TRP C34H on the network On Accessible IP s page click the modify box to activate the parameter Click on settings button to enter the IP Address and Net Mask of remote host that control the TRP C34H You can allow one of the following cases by setting the parameter Only one host of specific IP address can access the TRP C34H Enter IP address 255 255 255 255 e g 192 168 2 246 255 255 255 255 ...

Страница 21: ...255 128 192 168 2 129 to 192 168 2 254 192 168 2 128 255 255 255 128 Auto Warning Page Auto warning mechanism is a useful mechanism which sends the status messages to E Mail id s and Trap Servers in order to warn or acknowledge the changes made to the TRP C34H On Auto warning page under E mail and SNMP Trap Setting Tab click the modify box to activate the parameter a On Mail server frame input the...

Страница 22: ...the Auto warning are to be sent On Auto warning page under Event Tab click the Modify box to activate the parameter and click the checkbox to set the Events for which Auto warnings are to be sent To get Auto Warning E Mails i Give the Mail Server IP address authentication if required ii Give from ID To ID iii Select on what event you want to be notified by mail in Eventtype page To get Auto Warnin...

Страница 23: ...e notified v On that event notice that some messages will get printed on the console where you are executing the above snmptrapd command IP Address Report Page Network management becomes difficult when TRP C34H is forced into DHCP Any IP changes due to DHCP in TRP C34H are reported to the assigned Host on the Network On IP address Report click the modify box to activate the parameter and set the I...

Страница 24: ...rds are supported Space is not allowed between any characters in password 4 2 using the WEB Server mode TRP C34H support web console for remote configuration of the TRP C34H on the network To view the web console open any web browser eg Internet Explorer and type the IP address in the address bar of the browser A login form prompting for password appears Login to the web console by entering the co...

Страница 25: ...lnet from remote PC In the Basic Settings page of Windows Configuration Utility if the Enable Telnet Console check box is enabled we can use the Telnet Console to modify the device parameters Go to Start Menu Run Run Telnet from remote pc with the IP address of TRP C34H as shown below ...

Страница 26: ...nect PC RJ45 TRP C34H RS232 422 485 Device Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu Step3 Be sure IP Setting Port Setting and Operating Mode is correct Step4 Select Port Mapping then right clicks Add Device ...

Страница 27: ...27 Step5 The Port Mapping will show below Step7 Right Click select Apply Change ...

Страница 28: ...tep7 The TRP C34H Real COM Mode setting OK Notice No matter how to change Add device or Remove Device its need to be run Apply change for save COM Port configuration Step8 plug in RS232 LOOP back connector ...

Страница 29: ...29 Step8 RUN Demo exe and select setting Step9 Select Action then clicks Connect ...

Страница 30: ...upport multi ports TRP C34H supports 1 2 3 TRP C08X up to 8 12 16 COM Port Step1 Power off the TRP C34H and then connect TRP C08X Step2 Power on the TRP C34H will auto detection and configuration Step3 All operator steps same 5 1 ...

Страница 31: ... Connect Host PC 1 4 Ethernet TRP C34H PC Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu Step3 Be sure IP Setting Port Setting and Operating Mode is correct ...

Страница 32: ...nitor then right clicks Add Device Step5 Select Go Step5 Connect PC COM Port link TRP C34H COMA COMD by NULL Modem Cable Step6 RUN Demo exe and select correct baud rate and data format Step7 RUN Telnet exe and input IP and Port ...

Страница 33: ...33 5 3 Paired Mode Example ...

Страница 34: ...n the selected device and click on configure to go to Configuration menu Step3 Be sure IP Setting Port Setting and Operating Mode is correct Step4 TRP C34H Client setting Select Operating Mode and then double click Port1 Port4 item same below a Port 1 Setting ...

Страница 35: ...35 b Port 2 Setting c Port 3 Setting ...

Страница 36: ...36 d Port 4 Setting Step5 TRP C34H Server setting Select Operating Mode and then double click Port1 Port4 item same below ...

Страница 37: ...37 a Port 1 Setting b Port 2 Setting ...

Страница 38: ...38 c Port 3 Settings c Port 4 Setting ...

Страница 39: ...R LED ON first Step8 Power ON the TRP C34H Client and wait till it completely boots PWR LED ON Step9 Connect PC COM Port link TRP C34H Client COMA COMD by NULL Modem Cable Step10 Plug in TRP C34H server COMA COMD by DB 9 loop back connector Step11 RUN Demo exe and select correct baud rate and data format Step9 Select Action then clicks Connect ...

Страница 40: ...40 ...

Страница 41: ...41 6 TRP C34H Application Diagram ...

Страница 42: ...42 ...

Отзывы: