5
3
Preparing for use
3.1
Adjusting the handle height
Select the most comfortable handle height using
theadjustment lever on the handle, and lock in
position.
3.2 Filling the solution tank
•
The solution tank can be filled on or off the
machine. To fill the tank off the machine the
recovery tank must first be removed.
•
Remove vacuum hose and clear dome from
recovery tank and lift off tank.
•
Disconnect solution feed hose from solution
tank and lift tank off base. To release hose pull
connector collar forward (Fig.1).
Fig 1
•
Fill the solution tank with clean water using a
bucket, tap or hose, and an appropriate
measure of detergent.
•
Replace tanks on base and reconnect hoses.
•
Ensure solution hose is fully engaged and
captive in the connector allowing solution to
flow, thus preventing the pump from
overheating.
•
IMPORTANT - Only chemicals recommended
by the appliance manufacturer should be used,
i.e. low foaming, and follow the chemical
manufacturer’s directions regarding use,
handling, disposal and health and safety
provisions.
•
The tank capacity is 15 litres. Do not overfill
the tank as spillage may occur when in use.
•
IMPORTANT - When the solution tank has
emptied, switch off the machine and empty
the recovery tank before refilling the solution
tank.
4
Controls
The operating controls are located on the handle
and indicated in the logos above the switches
(Figs.2, 3, 4).
Fig 2
Fig 3
1 - Brush motor switch
Used to switch motor ON and OFF. Lights when
in the on position.
2 - Neon indicator
Lights when the machine is connected to
thepower supply.
3 - Vacuum motor switch
Used to switch motor ON and OFF. Provides
suction at the squeegee. Lights when in the on
position.
Fig 4
4 - Solution feed triggers
When squeezed supplies cleaning solution to the
brush head.
5 - Handle adjustment lever
Used to adjust handle to comfortable working
height.
6 - Cut-out reset button
Cut-out protects brush motor from overheating.
Press button once to reset cut-out and restart
motor.
7 - Cable winder
Used to hold supply cord in place on handle
when machine is not in use.
Содержание Solaris - SSD400