Preparing for use 

3.1 

Adjusting the handle height 

Select the most comfortable handle height using 
theadjustment lever on the handle, and lock in 
position. 

3.2  Filling the solution tank 

  The solution tank can be filled on or off the 

machine. To fill the tank off the machine the 
recovery tank must first be removed. 

  Remove vacuum hose and clear dome from 

recovery tank and lift off tank. 

  Disconnect solution feed hose from solution 

tank and lift tank off base. To release hose pull 
connector collar forward (Fig.1). 

 

 

 

Fig 1 

  Fill the solution tank with clean water using a 

bucket, tap or hose, and an appropriate 
measure of detergent. 

  Replace tanks on base and reconnect hoses. 

  Ensure solution hose is fully engaged and 

captive in the connector allowing solution to 
flow, thus preventing the pump from 
overheating. 

  IMPORTANT - Only chemicals recommended 

by the appliance manufacturer should be used, 
i.e. low foaming, and follow the chemical 
manufacturer’s directions regarding use, 
handling, disposal and health and safety 
provisions. 

  The tank capacity is 15 litres. Do not overfill 

the tank as spillage may occur when in use. 

  IMPORTANT - When the solution tank has 

emptied,  switch  off  the  machine  and  empty 
the  recovery  tank  before  refilling  the  solution 
tank. 
 
 
 
 
 
 
 
 
 
 

Controls 

The operating controls are located on the handle 
and  indicated  in  the  logos  above  the  switches 
(Figs.2, 3, 4). 
 
 
 
 
 
 
 

 
 

 

 

Fig 2 

 

                           

Fig 3 

 
1 - Brush motor switch 
Used  to  switch  motor  ON  and  OFF.  Lights  when 
in the on position. 
2 - Neon indicator 
Lights  when  the  machine  is  connected  to 
thepower supply. 
3 - Vacuum motor switch 
Used to switch motor ON and OFF. Provides 
suction at the squeegee. Lights when in the on 
position. 
 
 
 
 
 
 
 
 
 
 

Fig 4 

 
4 - Solution feed triggers 
When squeezed supplies cleaning solution to the 
brush head. 
5 - Handle adjustment lever 
Used to adjust handle to comfortable working 
height. 
6 - Cut-out reset button 
Cut-out protects brush motor from overheating. 
Press button once to reset cut-out and restart 
motor. 
7 - Cable winder 
Used  to  hold  supply  cord  in  place  on  handle 
when machine is not in use. 

 

 

 

 

Содержание Solaris - SSD400

Страница 1: ...1 User instructions Solaris SSD400 Scrubber dryer floor cleaning machine 03 7937 0000 Iss 3 04 14 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE ORIGINAL INSTRUCTIONS...

Страница 2: ...g the handle height 5 3 2 Filling the solution tank 5 4 Controls 5 5 Operation 6 5 1 Starting the machine 6 5 2 Changing the brush 6 5 3 Changing squeegee blades 6 5 4 Fitting the side brush 6 5 5 Whe...

Страница 3: ...oltage shown on the rating plate All parts are to be positioned as indicated in the instructions before using the machine Do not operate the machine if it malfunctions or is damaged in any way Contact...

Страница 4: ...do not lift large and heavy machines without assistance We advise that the manual handling regulations are followed Please refer to the technical table for details on weight of machine When transporti...

Страница 5: ...w the chemical manufacturer s directions regarding use handling disposal and health and safety provisions The tank capacity is 15 litres Do not overfill the tank as spillage may occur when in use IMPO...

Страница 6: ...he fitting of other brushes may affect its safety Always ensure machine is unplugged before fitting or removing parts To change the brush first remove both recovery tank and solution tank to reduce we...

Страница 7: ...ts should only be performed by trained staff Improper repairs can cause considerable dangers to the user 9 Guarantee Your product is guaranteed for one year from the date of original purchase or hire...

Страница 8: ...t 2 blades 10 0040 0000 Wet pick up IMPORTANT Genuine accessories are only available from authorised Service Agents or Truvox Customer Services Department Model Solaris SSD400 Voltage AC Frequency V H...

Страница 9: ...ioned Loose or broken drive belt Refit shaft Contact Service Agent Cleaning solution not flowing Solution hose not correctly fitted to tank connector Hose blocked Waterways in spray bar blocked Soluti...

Страница 10: ...transposed harmonised European Standards and technical specifications Ref No Title 2006 42 EC Machinery Directive and subsequent amendments 2006 95 EC The Low Voltage Directive and subsequent amendmen...

Страница 11: ...11...

Страница 12: ...12 Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com Authorised dealer...