11 Accessories
Item
Part No.
Usage
Fixed floor nozzle
FM100H
for VA55HD
Fixed floor nozzle
FM100
for VA55IND
Fixed floor nozzle
FM200
for VA75IND
IMPORTANT : Genuine accessories are only available from authorised Service Agents or Truvox
Customer Service Dept.
12 Fault diagnosis
The following simple checks may be performed by the operator.
Trouble
Reason
Remedy
Machine not working.
•
Lack of voltage/electrical supply.
•
Check fuse *, supply cord, plug
and socket outlet.
Loss of suction
•
Tank full.
•
Dry filter assembly clogged
•
Clogged hose or wand.
•
Tank rim is dented
•
Loose or broken fan
•
Motor not working
•
Float not functioning
•
Seal worn
•
Empty Tank
•
Clean cloth filter
•
Remove obstruction
•
Replace tank
•
Contact supplier
•
Contact supplier
•
Check to see if float moves freely
or tank is full.
•
Replace seal
Motor is not running
•
Broken switch
•
Defective power cord
•
Defective motor
•
Contact supplier
•
Contact supplier
•
Contact supplier
•
centre.
Dust blowing from unit when
running
•
Cloth filter dirty
•
Cloth filter is torn
•
Cloth filter is not installed
•
Clean cloth filter.
•
Replace filter.
•
Install cloth filter, when vacuuming
very fine dust,
Water blowing from unit when
running
•
Tank is full of liquid
•
Sudsy or foamy liquid is being
picked up
•
Empty tank.
•
Add defoamer to tank
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.