11  Accessories 

 

Item 

Part No. 

Usage 

Fixed floor nozzle 

FM100H 

for VA55HD 

Fixed floor nozzle 

FM100 

for VA55IND 

Fixed floor nozzle 

FM200 

for VA75IND 

IMPORTANT : Genuine accessories are only available from authorised Service Agents or Truvox 
Customer Service Dept. 
 

12  Fault diagnosis 

 

The following simple checks may be performed by the operator. 
 

Trouble 

Reason 

Remedy 

Machine not working. 

 

Lack of voltage/electrical supply. 

 

Check fuse *, supply cord, plug 
and socket outlet. 

Loss of suction 

 

Tank full. 

 

Dry filter assembly clogged 

 

Clogged hose or wand. 

 

Tank rim is dented 

 

Loose or broken fan 

 

Motor not working 

 

Float not functioning 

 

 

Seal worn 

 

Empty Tank 

 

Clean cloth filter 

 

Remove obstruction 

 

Replace tank 

 

Contact supplier 

 

Contact supplier 

 

Check to see if float moves freely 
or tank is full. 

 

Replace seal 

Motor is not running 

 

Broken switch 

 

Defective power cord 

 

Defective motor 

 

Contact supplier 

 

Contact supplier 

 

Contact supplier 

centre. 

Dust blowing from unit when 
running 
 

 

Cloth filter dirty 

 

Cloth filter is torn 

 

Cloth filter is not installed 

 

Clean cloth filter. 

 

Replace filter. 

 

Install cloth filter, when vacuuming 
very fine dust, 

Water blowing from unit when 
running 

 

Tank is full of liquid 

 

Sudsy or foamy liquid is being 
picked up 

 

Empty tank. 

 

Add defoamer to tank 

 

* If the fuse blows several times, the machine should be checked by an authorised Service Agent.  

Содержание VA20HD

Страница 1: ...tructions VA20HD VA55HD VA55IND and VA75IND Commercial wet dry vacuum cleaners CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03 8112 0000 Iss 3 07 08 http www truvox com Products Vacuums Va...

Страница 2: ...ne 3 2 Preparing for use 4 2 1 Electrical connection 4 2 2 Wet operation 4 2 3 Dry operation 4 3 Controls 4 4 Operation 4 5 Storage 5 6 Maintenance 5 7 After sales service 5 8 Guarantee 5 9 Waste Elec...

Страница 3: ...supply cord is damaged it has to be replaced Do not use where hazardous dust is present Do not use in an explosive atmosphere Do not pick up oil or other flammable material Take care when using a mac...

Страница 4: ...valve assembly must be in place 2 3 Dry operation For the VA55HD VA55IND and VA75IND both the primary filter cloth filter on frame and pleated paper filter must be in position for dry recovery 3 Cont...

Страница 5: ...r Service Department for rapid attention 7 After sales service Truvox machines are high quality machines that have been tested for safety by authorised technicians It is always apparent that after lon...

Страница 6: ...cilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the...

Страница 7: ...ken fan Motor not working Float not functioning Seal worn Empty Tank Clean cloth filter Remove obstruction Replace tank Contact supplier Contact supplier Check to see if float moves freely or tank is...

Страница 8: ...pean Standards and technical specifications BS EN 50081 1 BS EN 55014 1 2 BS EN 60335 1 and BS EN 60335 2 69 and is in conformity with the Machinery Directive 98 37 EC and subsequent amendments the Lo...

Отзывы: