background image

 

BEFORE OPERATING THIS MACHINE 

 

Read this manual carefully and completely before attempting to operate this unit.  This manual has 

important information for the use and safe operation of the machine.  Keep this manual handy at all times.  This 

machine will assure years of satisfactory service if operated and maintained according to recommendations in 

this manual.  If additional information is needed, please contact Cleanfreak at 1-888-722-5508 or write to: 

 

CleanFreak

P.O. Box 569 

Wausau, WI 54402 

 

WARNING!

   

 

The machine was designed for use on carpet, floor and upholstery extraction applications as per instructions and recommendations 

written in this manual.  Any deviation from its proper use or purpose and the consequential damage that may occur is the sole 

responsibility of the end user. 

 

Disconnect the power cord from the outlet before servicing.  Do not leave the machine connected to an electrical outlet when 

unattended. 

 

Do not immerse or use this machine in standing water.  Such use may cause electric shock. 

 

This equipment is not designed to handle or use combustible/volatile substances such as gasoline or kerosene, in, on, or near the 

machine.  The use of such materials will cause an extremely hazardous condition. 

 

When using an extension cord, use only a 3-prong conductor grounding cord- 12 gauge wire or heavier. 

 

To avoid electric shock, do not expose the machine to rain.  Store it indoors only. 

 

Do not use the machine for dry vacuuming, as it is not equipped with a fine dust filter. 

 

Use a defoamer at all times to prevent damage to the vacuum motors.  If defoamer is not used, or not used sufficiently, foam from 

your chemical or chemical left in the carpet from a previous cleaning may be ingested into and damage your vacuum motors. Failure 

to use a defoamer may cause water damage to the vacuum system and void warranty. 

 

Do not use water in excess of 135

°

F (57

°

C) in the solution tank as it may damage the solution system. 

 

To prevent seal damage and chemical build-up to the pump system, run clean water through the solution lines after each day’s use. 

 

Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of this type.  Do not use 

dyes, bleaches, ammonia, or other additives.  The use of powdered cleaning solution if not diluted properly may result in damage to 

the pump.  If powdered chemicals are used, premix in a separate container according to directions on the container before placing in 

the solution tank. Monitor and clean intake filters to prevent clogs. Replace damaged filters immediately to prevent damage to 

pump. 

 

Do not expose the machine to freezing temperatures, or store inside a room or vehicle where the temperature might drop to 

freezing temperatures.  

 

For troubleshooting or technical issues, please contact Cleanfreak. 

 

Do not use replacement parts other than those specified on the parts list or recommended by a Cleanfreak representative. 

 

 

FOR UNITS EQUIPPED WITH EXTERNAL HEATER 

 

Read and understand the External Heater owner’s manual before using the External heater on your Trusted Clean extractor. 

 

Do not run heater dry!  Turn on your pump and run solution completely through the system prior to turning on the heater.  Be 

advised that water in the tank does not ensure that water is in the heater.  Turn off your heater immediately if you run out of water 

in the machine, and do not activate again until water has once again been run through system. 

 

Water hookups must be in place and water flowing through the heater prior to turning it on.  Failure to do so may cause internal 

component damage and will void warranty. 

 

Heater must be filled with water or water based solutions at all times when in use.  Turn off the switch and unplug the heater from 

outlet when not in use. 

 

Do not use heater at more than 500 psi. 

 

Do not immerse heater in water. 

 

To avoid explosion and / or fire, do not use solvents or any flammable liquid in heater. 

 

FAILURE TO COMPLY WITH ABOVE WARNING INSTRUCTIONS WILL VOID THE WARRANTY 

Содержание TPL-5-100-UD-Heat-TCP

Страница 1: ...5 GALLON Owner s Manual Parts List This equipment is intended for commercial use only TRUSTED CLEAN MODELS TPL 5 100 UD TCP TPL 5 100 UD HEAT TCP 1 888 722 5508 ...

Страница 2: ...tank as it may damage the solution system To prevent seal damage and chemical build up to the pump system run clean water through the solution lines after each day s use Use only commercially available carpet cleaning solutions and defoamer intended for use with machines of this type Do not use dyes bleaches ammonia or other additives The use of powdered cleaning solution if not diluted properly m...

Страница 3: ...DDITIONAL INSTRUCTIONS FOR UNITS WITH OPTIONAL EXTERNAL HEATER INSTALLED 1 Be sure to fill the solution tank with water before plugging in the machine 2 Water hookups must be in place and water flowing through the heater prior to turning heater on Failure to do so may cause internal component damage and will void the warranty For more information see Warnings section 3 Spray water through the tool...

Страница 4: ...ming hose to the male fitting on your extractor 4 Insert the other end of the priming hose into the vacuum port You may need to hold this end of the hose in place 5 Turn on your pump Turn on your vacuum 6 Let the machine run until you can see the water flowing consistently through the priming hose with no air bubbles This should only take 5 25 seconds 7 Turn off the pump and vacuum 8 Your pump is ...

Страница 5: ...dirt build up on wand head 4 Defective vacuum hose 5 Loose connection in the vacuum motor s SOLUTION SYSTEM Pump motor on no spray through spray tips 1 Clogged spray tips 2 Clogged solution intake filter screen 3 Plugged female quick disconnect coupler or couplers not fully engaged 4 Punctured pump diaphragm 5 Defective or clogged check valve 6 Crack in pump housing 7 Lost prime Uneven or weak spr...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ...NOTES REVISED 10 24 2012 ...

Отзывы: