Page 9
www.kuebler.com
Seite 9
Count mode SUBTRACT
Output 1 active when
count status < preset value 1
Output 2 active when
count status < 0
Reset to preset 2
Count mode ADDING with
automatic reset
Output 1 active when count
status > preset value 1
Output 2 (timed signal) active
when count status = preset value
2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic
reset
Output 1 active when count
status < preset value 1
Output 2 (timed signal) active
when count status = 0
Automatic reset to preset 2 when
count status = 0
Reset to preset 2
Count mode ADDING with
automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset 2
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter > preset 1
Manual reset sets both counters
to zero.
Electrical reset only sets the
main counter to zero.
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset 2 when
main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when Batch
counter > preset 1
Manual reset sets main counter
to preset value 2 , batch counter
to zero
Electrical reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter > preset value 1
Manual Reset sets both counters
to zero
Electrical reset only sets the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset value 2
when main counter = zero
Total counter counts (sub from
preset value 1) all count pulses
from main counter
Output 1 active when Total
counter < zero
Manual reset sets both counters
to the preset values
Electrical reset sets only main
counter to preset value 2
Tracking Preset mode
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero
Preset 1 relative to preset 2 (see
also section 17. Output
operations)
Tracking Preset mode with
automatic reset
When preset 2 is changed then
preset 1 automatically tracks it.
Reset to zero.
Automatic reset to zero when
main counter = preset value 2.
Preset 1 relative to Preset 2
(see also section 17. Output
operations)