Count mode SUBTRACT 

Output 1 active when   

count status < preset value 1 

Output 2 active when   

count status < 0  

Reset to preset 2 

Count mode ADDING with 

automatic reset 

Output 1 active when count 

status > preset value 1 

Output 2 (timed signal) active 

when count status = preset value 

Automatic reset to zero when 

count status = preset value 2 

Reset to zero 

Count mode SUBTRACTING 

with  automatic

 

reset 

Output 1 active when count 

status < preset value 1 

Output 2 (timed signal) active 

when count status = 0 

Automatic reset to preset 2 when 

count status = 0 

Reset to preset 2 

Count mode ADDING with 

automatic reset and Batch 

counter 

Output 2 (timed signal) active 

when main counter = preset 

value 2 

Automatic reset to zero when 

main counter = preset 2 

Batch counter counts the number 

of automatic repetitions of preset 

Output 1 active when  Batch 

counter > preset 1 

Manual reset sets both counters 

to zero.  

Electrical reset only sets the 

main counter to zero.  

Count mode SUBTRACTING 

with automatic reset and Batch 

counter 

Output 2 (timed signal) active 

when main counter = zero 

Automatic reset to preset 2 when 

main counter = zero 

Batch counter counts the number 

of automatic repetitions of preset 

Output 1 active when Batch 

counter > preset 1 

Manual reset sets main counter 

to preset value 2 , batch counter 

to zero 

Electrical reset only sets the 

main counter to preset value 2 

Count mode ADDING with 

automatic reset and Total 

counter 

Output 2 (timed signal) active 

when main counter = preset 

value 2 

Automatic reset to zero when 

main counter = preset value 2 

Total counter counts all the count 

pulses from the main counter 

Output 1 active when total 

counter > preset value 1 

Manual Reset sets both counters 

to zero 

Electrical reset only sets the 

main counter to zero 

Count mode SUBTRACTING 

with automatic reset and Total 

counter 

Output 2 (timed signal) active 

when main counter = zero 

Automatic reset to preset value 2 

when main counter = zero 

Total counter counts (sub from 

preset value 1) all count pulses 

from main counter 

Output 1 active when Total 

counter < zero 

Manual reset sets both counters 

to the preset values 

Electrical reset sets only main 

counter to preset value 2 

Tracking Preset mode 

When preset 2 is changed then 

preset 1 automatically tracks it.  

Reset to zero 

Preset 1 relative to preset 2 (see 

also section 17. Output 

operations) 

Tracking Preset mode with 

automatic reset 

When preset 2 is changed then 

preset 1 automatically tracks it.  

Reset to zero. 

Automatic reset to zero when 

main counter = preset value 2. 

Preset 1 relative to Preset 2  
(see also section 17. Output 

operations) 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 924K

Страница 1: ...924K Electronic Preset Counter with two presets Installation and Operating Instructions www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...12 7 9 Setting the presets 16 7 9 1 Setting via Decade Keys 16 7 9 2 Setting with Teach In Function 16 7 9 3 Setting the tracking presets 16 7 10 Set Function 16 8 Error message 16 9 Connections 17 9...

Страница 3: ...damaging the machine or causing an accident to the operators then it is your responsibility to take the appropriate safety measures 2 2 Mounting in a control panel CAUTION Mount the device away from...

Страница 4: ...or 10 30 VDC 4 Display Operating elements T1 6 Decade key T1 T6 P Prog Mode key R Reset key 8 Current count value main counter 9 Preset value Total count Batch counter 10 Run display for Timer 11 Sho...

Страница 5: ...xt and T1 back 7 3 Entering a sub menu The sub menu is opened with the Prog Mode key and the first menu item is displayed 7 4 Selecting the menu items The Prog Mode key is used to select a menu item w...

Страница 6: ...etting Parameter set 3 Freely programmable User settings Factory settings are highlighted in grey 7 8 2 Table Parameter Sets P SEt 1 P SEt 2 P SET 3 Func Count Count Count InP PoL PnP PnP PnP FiLtEr o...

Страница 7: ...rement A B Inp A count input A Inp B count input B Percentage differential counting A B A in Inp A count input A Inp B count input B User input When the MPI input is activated the display is frozen an...

Страница 8: ...ter preset 1 Manual reset sets main counter to preset value 2 batch counter to zero Electrical reset only sets the main counter to preset value 2 Count mode ADDING with automatic reset and Total count...

Страница 9: ...lay colour upper line red lower line red Display colour upper line red lower line green 7 8 4 4 Submenu for reset mode Setting the reset mode Manual reset with red key and electrical reset reset input...

Страница 10: ...Lock input is activated the setting of the preset values and the programming are both inhibited 7 8 5 2 Submenu for configuration Submenu for matching the input pulses and display Multiplication facto...

Страница 11: ...top Edge to Inp B Start 1 Edge to Inp B Stop 2 Edge to Inp B Timing can only be controlled via the Gate input Inp A and Inp B no function The timer is reset by means of a RESET to zero when adding to...

Страница 12: ...petitions of preset 2 Output 1 active when batch counter preset 1 manual reset sets both counters to zero electrical reset sets only main counter to zero Count mode SUBTRACTING with automatic reset an...

Страница 13: ...imal place 0 0 1 decimal place 0 00 2 decimal places 0 000 3 decimal places Set value Set value can be programmed from 000000 to 999999 A previously programmed decimal point will be displayed Display...

Страница 14: ...t Preset 1 Duration of timed signal of Output 1 programmable from 00 01 to 99 99 s Timed signal is post triggered 7 8 6 6 Submenu for Preset 2 Submenu for Preset 2 ADD mode output operations permanent...

Страница 15: ...ue will be accepted and the counter will switch back to operating mode 7 9 2 Setting with Teach In Function Program the MPI input to tEAch In programming mode select the preset to be changed using the...

Страница 16: ...0 VDC Supply voltage 15 AC 90 260 VAC L DC GND 0 VDC Supply voltage 10 Technical Data 10 1 General Data Display LCD positive or negative backlit 2 x 6 digit Digit height upper line 9 mm lower line 7 m...

Страница 17: ...tching cycles 20x106 N of switching cycles at 3 A 250 V AC 5x104 N of switching cycles at 3 A 30 V DC 5x104 or NPN optocoupler Switching capacity 30 V DC 10 mA UCESAT for IC 10 mA max 2 0 V UCESAT for...

Страница 18: ...es 6 924 X1XX XX0 Input trigger levels 0 Standard HTL A 5V Supply voltage 0 90 260 VAC 3 10 30 VDC LCD version 0 no backlighting 1 green backlighting 2 LED Look 3 Multicolour Outputs 0 Relay 1 Optocou...

Страница 19: ...2 7 kHz 2 4 kHz Up Dn Up Up 9 kHz 2 7 kHz 2 4 kHz Quad Quad 2 9 kHz 1 2 kHz 1 2 kHz Quad 4 9 kHz 1 2 kHz 0 9 kHz A B A B A 9 kHz 13 2 Frequency meter HTL level AC supply typ Low 2 5 V typ High 22 V D...

Страница 20: ...ount input add Inp B Count input sub Add Display 0 Preset Sub Display Preset 0 Up Up Inp A Count input 1 add Inp B Count input 2 add Add Display 0 Preset Quad A 90 B Inp A Count input Count on one edg...

Страница 21: ...unt input Count on rising and on falling edges Inp B Count input Count on rising and on falling edges Reverse direction Add Display 0 Preset Sub Display Preset 0 A B Inp A Count input 1 Inp B Count in...

Страница 22: ...ction Inp B Start Stop Add Display 0 Preset Sub Display Preset 0 FrRrun Inp A no function Inp B no function Control of the timing only via the GATE input Add Display 0 Preset Sub Display Preset 0 Auto...

Страница 23: ...cy input 1 Inp B Frequency input 2 Formula A B AaddB Inp A Frequency input 1 Inp B Frequency input 2 Formula A B Quad A 90 B Inp A Frequency input 1 Inp B Reverse direction A B Inp A Frequency input 1...

Страница 24: ...5 17 Output operations Mode Diagram Mode Diagram Only in the mode and Additionally in the mode and Add Sub AddAr SubAr AddBat SubBat AddTot SubTot www GlobalTestSupply com Find Quality Products Online...

Страница 25: ...Page 26 www kuebler com Seite 26 Mode Diagram Trail TrailAr www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 26: ...hl und Sensortechnik P O Box 3440 D 78023 Villingen Schwenningen Germany Tel 49 0 77 20 39 03 0 Fax 49 0 77 20 2 15 64 sales kuebler com www kuebler com R600318 91 4 25 max 10 5 7 45 48 48 15 5 Panel...

Отзывы: