background image

Items sensitive to heat (e.g. spray cans) must not be stored 

in the installation area, since excess temperatures may under 

circumstances be incurred there.

Only pressure control equipment that complies with EN 12864 

(in vehicles) with a fixed delivery pressure of 30 mbar must be 

used for the gas system. The flow rate of the pressure control 

device must correspond to at least the maximum consump-

tion of all devices installed by the system manufacturer.

Im portant  operat ing notes

If the cowl has been placed near or directly beneath an open-

ing window, the device must be equipped with an automatic 

shut-off device in order to prevent operation with the window 

open.

Always mount the cowl cap if the water heater is not being 

used. Non-observance of this point can lead to the function of 

the appliance being impaired through water, dirt or insects.

Before setting off on any journey, fit cowl cap with the 

boiler switched off. Please ensure that it is secure and 

has locked into place (risk of accident). Defective cowl caps 

must not be used.

There shall be no claim under guarantee if this point is not 

observed. Always remove the cowl cap prior to operating the 

water heater!

If just the cold water system is being used, without water 

heater, the heater tank is also filled up with water. In order 

to avoid damage through frost, the water contents must be 

drained by actuating the safety/drain valve, also when the 

heater has not been used. As an alternative, two shut-off 

valves, resistant to hot water, can be fitted in front of the cold 

and hot water connection. 

Drain the w ater heater if there is a risk  of  frost ! There 

shall be no claim  under guarantee if  t his point  is not  

observed.

If connecting to a central water supply (rural or city connec-

tion) or when using more powerful pumps, a pressure  reducer 

must be used which prevents pressures of greater than 2.8 bar 

occurring in the Ultrastore.

Safety instruct ions

The use of upright gas cylinders from which gas is t aken in 

t he gas phase is mandatory for the operation of gas regula-

tors, gas equipment and gas systems. Gas cylinders from 

which gas is taken in the liquid phase (e.g. for fork lifts) must 

not be used, since they would result in damage to the gas 

system.

In event of leaks in the gas system or if there is a smell of gas:

extinguish all naked flames

do not smoke

switch off all appliances

shut off the gas cylinder

open the windows and doors

do not actuate any electrical switches

have the entire system checked by an expert!

Repairs may only be carried out by an expert.

During use, please observe the regulations of EN 60335-1:2010, 

according to which this device has not been designed for use 

by people (including children) who have restricted physical, 

sensory or mental abilities or a lack of experience and / or 

knowledge, unless they are supervised by a person respon-

sible for their safety or have received instructions from that 

person as to how the device is to be used.

Children should be supervised to ensure they do not play with 

the device.

To avoid risk caused by unintentional resetting of the 

overtemperature sensor, the device may not be supplied 

via an external sw itching device, such as a timer, or be con-

nected with a circuit that is regularly switched on and off by 

any kind of equipment.

Guarantee claims, warranty claims and acceptance of liability 

will be ruled out in the event of the following:

modifications to the unit (including accessories),

modifications to the exhaust duct and the cowl,

failure to use original Truma parts as replacement parts and 

accessories,

failure to follow the installation and operating instructions.

It also becomes illegal to use the appliance, and in some 

countries this even makes it illegal to use the vehicle.

The operating pressure for the gas supply (30 mbar) must cor-

respond to the operating pressure of the appliance (see data 

plate).

Liquid gas systems must accord with the technical and 

 administrative regulations of the particular country in which 

they are being used (e.g. EN 1949 for vehicles). National 

 regulations must be respected.

The testing of the gas system must be repeated every tw o 

years by a qualified specialist and, if appropriate, confirmed 

on the inspection certificate.

The vehicle ow ner is alw ays responsible for arranging 

t he inspection.

Liquid gas equipment must not be used when refuelling, 

in multi-storey car parks, in garages or on ferries.

During the initial operation of a brand new appliance (or after 

it has not been used for some time), a slight amount of fumes 

and a slight smell may be noticed for a short while. Remedial 

action here is to immediately run the heater and to ensure ad-

equate room ventilation.

If the burner makes an unusual noise or if the flame lifts off, 

it is likely that the gas pressure regulator is faulty and it is 

 essential to have it checked.

4

Содержание Ultrastore Rapid GE

Страница 1: ...Operating instructions Page 3 Installation instructions Page 9 To be kept in the vehicle Ultrastore Rapid GE ...

Страница 2: ...el etc Do not switch the Ultrastore off when showering As long as the Ultrastore remains in operation other people can shower as the water is continually reheated 0 10 20 30 40 50 60 70 80 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 2 minutes 1 minute 1 minute 3 minutes 2 minutes 1 minute Time t minutes 3 minutes 1 minute 2 minutes 1 minut...

Страница 3: ... arrant y 8 Installation instructions Intended use 9 Regulations 9 Water heater kit 9 Choice of location 9 Installation of the w ater heater 9 Water connection 10 John Guest System rigid pipe routing 10 Flexible water hose routing 11 Installation of the safety pressure relief drain valve 11 Water pipe routing 11 Gas connection 11 Installation of the control panels 12 Electrical connection 12 V 12 ...

Страница 4: ...ames do not smoke switch off all appliances shut off the gas cylinder open the windows and doors do not actuate any electrical switches have the entire system checked by an expert Repairs may only be carried out by an expert During use please observe the regulations of EN 60335 1 2010 according to which this device has not been designed for use by people including children who have restricted phys...

Страница 5: ...e Lever in vertical position position f The water heater is now drained directly to the outside via the safety drain valve Check that the water contents have been completely drained 10 litres Sw itching on Gas operation Ultrastore 50 70 b c b a a Red LED Failure b Water heater On 50 C or 70 C c Water heater Off Never operate the water heater without water in it If the cowl is positioned vertically...

Страница 6: ...l p c b s as spare parts Disposal The device must be disposed of in line with the administrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Technical data Determined in accordance with EN 15033 or Truma test conditions M anufacturer Truma Gerätetechnik GmbH Co KG P O Box 1252 856...

Страница 7: ...appliance wait 5 minutes and switch on again Electrical operation When switching on the heater does not operate No 230 V supply voltage Over temperature sensor has responded Too slow warm up in position 850 W Connect the caravan to the site supply and or check residual current circuit breaker Check water content refill if required close drain valve The electrical heating element is fitted with an ...

Страница 8: ... relevant service partners should be contacted see Truma Service Booklet or www truma com Any complaints are to be described in de tail Please also specify the device serial number and date of purchase In order for the manufacturers to be able to determine whether an incident subject to guarantee has occurred the end user must at his own risk bring the device to the manufacturers or send it to the...

Отзывы: