Technical data

Determined on the basis of EN 14511 or Truma test conditions

Designation

Saphir comfort RC AU, comfort air conditioning system

Number of structural units

1

Dimensions L x W x H

628 x 400 x 290 mm

Weight

approx. 23.5 kg

Power supply

230 V – 240 V ~, 50 Hz

Maximum cooling power

2.4 kW

Heating power

1.7 kW

Effective power consumption

0.98 kW

Starting current

20 A (150 ms)

Power consumption

4.2 A / 35 °C

Protection class

IP X5

Energy Efficiency Rate (EER)

2.4

Volume flow (cold air)

max. 380 m³/h

Refrigerant

R 407C

Refrigerant content

see type plate on unit

Compressor oil

Diamond MA32, 300 cm³

Noise

depending on installation situation

Maximum incline of vehicle during operation

5° / 8 %

Usage limits

+4 °C to +43 °C.

 

– An interior air sensor prevents the compressor from operat-

ing at temperatures of less than +16 °C during cooling.

 

– An anti-freeze sensor prevents non-permitted ice formation 

on the evaporator coil.

 

– A temperature switch prevents excessive current and tem-

perature at the compressor.

 

Right reserved to make technical changes!

Circulated air intake 

from inside

Cold air / 
warm air outlet

Supply air 

intake from 

the outside

Supply air outlet 

to the outside-

downwards

Throttle

Compressor

Fan

Fan

Filter

Function diagram

Evaporator /

condenser

Condenser /

evaporator

Fig. 10

IR remote control battery change

Only use micro-batteries that will not leak, type LR 3, AM4, 

AAA, MN 2400 (1.5 V). 

The battery compartment is on the rear of the remote control.

When inserting new batteries, make sure the positive / nega-

tive terminals are connected correctly!

Fig. 7

Empty, used batteries can leak and damage the remote 

control! Remove the batteries if the remote control is 

not being used for a long period of time.

The tuning between the remote control and the air con-

ditioning system is retained if the batteries are removed.

No warranty given for damage caused by leaking 

batteries. 

Disposal

Before disposing of a defective remote control, always re-

move the batteries and dispose of them correctly.

The device must be disposed of in accordance with the ad-

ministrative regulations of the respective country in which it is 

used. National regulations and laws (in Germany, for example, 

the End-of-life Vehicle Regulation) must be observed.

Accessories

Sound muffler for installation in the cold air duct for additional 

noise reduction inside the living compartment. 

(Part no. 40090-00038).

Fig. 8

The flexible air conditioning intake allows the air conditioning 

system to be installed in a space that is sealed off from the 

interior (e.g. false floor or rear storage space) and prevents 

contaminated air from being drawn in. 

(Part no. 40090-59100).

Fig. 9

Содержание Saphir comfort RC AU

Страница 1: ...Operating instructions Page 2 Installation instructions Page 9 To be kept in the vehicle Saphir comfort RC AU...

Страница 2: ...ns 8 Truma warranty policy 8 Fig 1 Fig 2 Installation example 1 Saphir comfort RC AU 2a Supply air intake 2b Supply air outlet 3a Circulated air intake 3b Air outlets 4 Infrared IR remote control 5 In...

Страница 3: ...ong periods with the vehicle at an angle since the conden sation that is produced may not be able to run away and may penetrate the vehicle under un favourable circumstances In order to ensure that th...

Страница 4: ...e Operating mode selection button Cooling Heating Automatic Circulated air Temperature selection buttons 16 31 C In 1 C steps On Off switch Reset Resets the remote control to the factory settings Fan...

Страница 5: ...ired operating mode by pressing the MODE button one or more times Cooling Heating Automatic cooling or heating mode depending on the room temperature setting Circulated air When the room temperature t...

Страница 6: ...from above Then remove particle filter p from the front Re fit the clip and the sensor in the same position during assembly Fig 6 When installing the particle filter p the printed arrows must point to...

Страница 7: ...nction diagram Evaporator condenser Condenser evaporator Fig 10 IR remote control battery change Only use micro batteries that will not leak type LR 3 AM4 AAA MN 2400 1 5 V The battery compartment is...

Страница 8: ...ling a service technician please check carefully the operating instructions service booklet and warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty...

Страница 9: ...ooled is drawn in again from the vehicle interior by the device via openings with a total area of at least 300 cm The circulated air is cleaned and dried during the opera tion of the device For this r...

Страница 10: ...t nozzles Ensure that the cold air ducts are firmly seated in the cold air outlets For noise reduction purposes Truma can supply a sound muffler for in stalling in the cold air system part no 40040 60...

Страница 11: ...the electrical connection but serve as additional infor mation for an expert who is employed to do the work Make the connection to the mains via the 150 cm long con nector cable 20 to a line that is...

Страница 12: ...relevant service partners should be contacted see www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 1300 07 2...

Отзывы: