Technical Data
Operational voltage
Direct voltage 10.8 – 16 V
Ambient temperature
-20 °C up to +35 °C
Front plate
Aluminum
Width
88 mm
Height
93 mm
Depth
20 mm
Weight
70 g
The right to effect technical modifications is reserved!
Maintenance
Clean the panel with a dry and fluff-free cloth.
Disposal
The device must be disposed of in line with the administrative
regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
Troubleshooting
Error
Rectification
The filling level display
is not shown for the
waste water tank.
Press the master switch.
Check the connection and the
cable to the waste water tank
and the connection and cable to
the MES Module B.
–
–
The filling level display
is not shown for the
freshwater tank.
Press the master switch.
Check the connection and the
cable to the freshwater tank and
the connection and cable to the
MES Module B.
–
–
The voltage display is
not shown.
Press the master switch.
Check the connection and the
cable to the MES Module B.
–
–
The charging control
display is not shown.
Check the connection and the
cable of the MES Module B.
–
The main switch does
not react.
Check the connection and the
cable to the MES Module B and
the fuses and connections of the
MES Module A and B. See the
operating instructions for the
MES Module B.
–
If these measures do not solve the problem, please