 Fault

 Cause

 Rectification

yellow LED flashes 4 x
(After operating for a longer pe-
riod of time, the heating system 
switches to failure)

 

– Summer mode with empty 

 water container

 

– Switch unit off and allow to cool,

fill boiler with water

 

– Warm air outlets blocked

 

– Check individual outlet apertures

 

– Circulated air intake blocked

 

– Remove blockage from circulated air intake

yellow LED flashes 5 x

 

– Room temperature sensor or 

cable defective

 

– Please contact Truma Service

yellow LED flashes 7 x

 

– Control panel or control panel 

cable defective

 

– Please contact Truma Service

yellow LED flashes 8 x

 

– FrostControl heating element 

has a short circuit

 

– Disconnect heating element plug from electronic control unit, re-

place heating element

yellow LED flashes 9 x
(approx. 30 seconds after switch-
ing on the heating system)

 

– Gas cylinder or quick-acting 

valve in gas supply line closed

 

– Check gas supply and open valves

 

– Gas cylinder empty

 

– Replacing a gas cylinder

(After operating for a longer pe-
riod of time, the heating system 
switches to failure)

 

– Gas pressure regulation system 

iced up

 

– Use regulator heater (EisEx)

 

– Butane content in the gas cylin-

der too high

 

– Use propane (butane is unsuitable for heating, particularly at tem-

peratures below 10 °C)

Red LED flashes 1 - 8 times

 

– Heating system fault

 

– Please contact Truma Service.

Determine flashing code (short, long) if necessary: Red LED on 
heater electronics.

Green LED flashes (with 5 Hz) 
after the heating system has been 
switched off

 

– After-running is active to reduce 

the temperature of the unit

 

– No fault. After-run switches itself off after max. 5 minutes. 

Room heating does not react to 
adjustment immediately

 

– After-running is active to reduce 

the temperature of the unit

 

– No fault. After-run switches itself off after max. 5 minutes

After switching on the green and 
the red LED illuminate 

 

– Faulty electronics

 

– Please contact Truma Service

If these actions do not remedy the problem, please contact Truma Service.

Содержание CP classic

Страница 1: ...hren Operating instructions Page 13 Installation instructions Page 22 To be kept in the vehicle Mode d emploi Page 24 Instructions de montage Page 33 garder dans le v hicule Istruzioni per l uso Pagi...

Страница 2: ...23 Assembly 24 Symbols used The unit must only be installed and repaired by an expert Note containing information and tips Please pay attention to the ESD regulations Electrostatic charge can destroy...

Страница 3: ...ing or with drained water system Operating instructions e Heating and hot water mode heating with water temperature monitoring f Rotary switch Off g Yellow LED lit Boiler heat up phase yellow LED flas...

Страница 4: ...he yellow LED o at the power selector switch indicates that the unit is operating with 230 V Heating with water temperature monitoring Move rotary switch on control panel to On position e Set the rota...

Страница 5: ...elect the required operating level according to the tempera ture difference between the setting on the control panel and the current room temperature Once the room temperature selected on the control...

Страница 6: ...ow LED o on the power selector switch illuminates and the red LED h or the yellow LED g on the control panel flashes Possible causes can be found in the troubleshooting guide If the flame goes out dur...

Страница 7: ...the heating system does not operate The temperature setting on the control panel is lower than the room temperature Select higher room temperature at the control panel After switching on the heating...

Страница 8: ...heck gas supply and open valves Gas cylinder empty Replacing a gas cylinder After operating for a longer pe riod of time the heating system switches to failure Gas pressure regulation system iced up U...

Страница 9: ...th 5 Hz after the heating system has been switched off After running is active to reduce the temperature of the unit No fault after run switches itself off after max 5 minutes Red LED flashes 6 x Lack...

Страница 10: ...s are connected Warm air outlets blocked Circulated air intake blocked Check whether the 4 warm air ducts are connected Check individual outlet apertures Remove blockage from circulated air intake Sum...

Страница 11: ...istrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Declaration of conformity T...

Страница 12: ...tered see Truma Service Booklet or www truma com In order to avoid delays please have the unit model and factory number ready see type plate Veuillez vous adresser au centre de SAV Truma ou un de nos...

Отзывы: