5
Energy selection
When the menu is selected the yellow LED shines.
Depends on summer / winter operation (see setup)
Use key
or
to select the energy source and confirm
with
.
Bar shows current mode
Summer operation
230 V – 4 A
(electro mode 230 V, 900 W)
230 V – 8 A
(electro mode 230 V, 1800 W)
Gas powered
Winter operation
230 V – 4 A
(electro mode 230 V, 900 W)
230 V – 8 A
(electro mode 230 V, 1800 W)
Gas powered
230 V – 4 A and gas (mixed operation gas and electro mode
900 W)
230 V – 8 A und Gas and gas (mixed operation gas and
electro mode 1800 W)
If electro or mixed operations are selected and there is
no 230 V power supply, the heating will not function.
–
–
Water temperature
When the menu is selected the yellow LED shines.
During the heating-up phase, the set water temperature flash-
es in the main screen.
Use key
or
to select the water temperature and
confirm with
.
Bar shows current mode
Depends on summer / winter operation (see setup)
Summer operation
Water 40 °C
Water 60 °C
Winter operation
Water > 0 °C
(heating
without
controlled water tempera-
ture, heating has priority)
Water 60 °C
Timer mode
The heater runs in timer mode as soon as one or both timers
have been activated in the setup
“Timer On” appears in the main screen
The heater is only active in the set time window
(active timer)
Only the energy selection can be changed in the case of
an active timer
A change in the room or water temperature will automati-
cally switch the control system into manual mode
–
–
–
–
–
–
–