Once the water in the boiler has reached a temperature of 60 °C, the burner will switch off. The
appliance must stay switched on for at least 30 minutes and no hot water may be removed. The
residual heat in the heat exchanger will
heat the water up to 70 °C.
Fuses
Fuse 12 V
The fuse is in the electronics beneath the connection cover.
Always replace the fuse of the unit with an identical fuse.
230v (Combi E)
The fuse and the power supply lines must only be replaced by an expert!
The unit must be disconnected from the mains (all poles) before opening the electronic housing lid.
The fuse is in the power electronics housing lid.
This fine fuse must always be replaced with a fuse of the same type:
230 V overheating switch.
If the 12 V power supply is interrupted during operation or during the after-run period, for example,
the temperatures within the unit could activate the overheating protection.
To reset the overheating protection, allow heater to cool, remove connection
cover and press red reset button.