Water pipe routing

Connect the cold water supply (15) via the pressure reducer 

(10) to the drain valve (14).

13

14

10

15

16

12

22

Fig. 17

Make a connection (16) for cold water supply between drain 

valve (14) and elbow (13 – lower pipe) on water heater.

Route the hot water pipe (22) from the elbow with integrated 

breather valve (12 – upper pipe) to the hot water appliances.

Gas connection

Refer to AS5601 – Gas Installations, for gas pipe sizing.

The gas inlet connection is a SAE 45° Flare 1/2 - 20UNF type.

For connection to 8 mm steel piping Truma povides an adapt-

er UNF 1/2 in. x RVS 8, part no. 70020-02700.

5/16 in.

8 mm

RVS 8

Pressure 
Testpoint

SAE 45° Flare
1/2 in. - UNF

Fig. 18

Before connecting to the water heater make sure that the gas 

lines are free from dirt, chips and such!

Route the pipes in such a way that the appliance can be 

removed again for servicing.

Before starting up for the first time, verify the correct installa-

tion in accordance to the requirements of AS5601 (check for 

gas leaks and check the gas pressure). Do not check for gas 

leaks with a naked flame.

Installation of the elbow water connectors

Push elbow fitting without aeration valve

 

(13) as far as 

possible onto the Truma UltraRapid HWS cold water con-

nection tube (lower tube), and push the elbow fitting with 

built-in aeration valve

 

(12) as far as possible onto the 

Truma UltraRapid HWS hot water connection tube (upper 

tube). Pull in the opposite direction to check that the elbow 

fittings are securely attached.

Slide venting hose with an outer diameter of

 

11

 

mm (20) onto 

the hose nozzle of the aeration valve (21) and route to the out-

side free of kinks. Radius of arc must not be less than 40 mm.

Cut off the venting hose about 20

 

mm below the vehicle floor 

at a 45° angle to the direction of travel.

45º

20 mm

21

13

12

20

Ø 12 mm

Fig. 14 

 

In industrial bulk packs the water connections are preinstalled 

and have to be tightened after the water pipes have been con-

nected. Please check for leaks before starting up for the first time.

Installation of the drain valve

Install the drain valve (14) at a place which is easily accessi-

ble, near the water heater. 

The drain valve must be installed lower than the cold water 

connection of the Truma UltraRapid HWS. 

Drill a hole with 18 mm diameter and pass through the dis-

charge tube. Fasten drain valve with two screws. The draining 

is to be directly to the outside at a position protected against 

splash water (apply splash guard, if necessary).

Ø 18 mm

14

Fig. 15

Installation of the pressure reducer

The pressure reducer (10) must be fitted between the drain 

valve and water pump in accordance with the 

direction of 

flow.

 Fasten the pressure reducer to the floor.

10

Fig. 16

Содержание BGA 14

Страница 1: ...Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle Truma UltraRapid Hot Water System LPG and 230 V 240 V Electric Storage Water Heater...

Страница 2: ...t finding 5 Technical data 6 Truma warranty policy 7 Installation instructions Data label 8 Intended use 8 Regulations 8 Water heater kit 8 Choice of location 8 Installation of the water heater 8 Wate...

Страница 3: ...sits and to en sure that it is not blocked Any discharge pipe connected to the safety pressure relief valve is to be installed in a continuously downward direction and in a frost free ambient Before a...

Страница 4: ...of accident Defec tive cowl caps must not be used Always observe the operating instructions prior to starting The vehicle owner is responsible for correct opera tion of the appliance Before using the...

Страница 5: ...fail to pack it correctly the warranty shall no longer be valid Only use original Truma UltraRapid HWS PCB as spare parts Fault finding Gas operation Symptom Cause When switching on the heat er does n...

Страница 6: ...65 C 14 litres Gas operation approx 45 min Electrical operation approx 40 min Gas and electrical operation approx 28 min Power consumption 12 V Ignition 0 160 A Heating up 0 12 A Stand by 0 05 A Powe...

Страница 7: ...check carefully the operating instructions warranty terms and conditions If the product fails for any of the reasons detailed therein or is faulty due to abuse misuse or improper installation then a s...

Страница 8: ...out by properly qualified professionals This appliance shall be installed in accordance with the manu facturer s installation instructions local gas fitting regulations municipal building codes electr...

Страница 9: ...so for cold water pressures of up to 400 kPa can occur in the drain valve also with submergible pumps because of the heat of the water and the resulting expansion All hot water pipes should be routed...

Страница 10: ...tube and push the elbow fitting with built in aeration valve 12 as far as possible onto the Truma UltraRapid HWS hot water connection tube upper tube Pull in the opposite direction to check that the e...

Страница 11: ...8b 28 35 34 36 Fig 20 When power packs or power supply units are being used note that the regulated output voltage is between 11 V and 15 V and the alternating current ripple is 1 2 Vpp Installation o...

Страница 12: ...heck After installation check gas supply line for leaks in accord ance with the pressure drop method Following this check the function of the appliance as specified in the operating in structions in p...

Страница 13: ...13 When ordering spare parts please always state the serial number and year of manufacture BGA 14 BGEA 14 LPG Propane and 230 V 240 V Electric Storage Water Heater...

Страница 14: ...own BU blue GN green GY green yellow OG orange RD red WH white YE yellow WH BN GN YE GY Electrical Connection Diagram Truma UltraRapid Hot Water System Safety Valve PC Push Coil HC Holding Coil RD GN...

Страница 15: ...Notes...

Страница 16: ...elevant service partners should be contacted www truma com Having the equipment model and the serial number ready see type plate will speed up processing Service Australia Telephone 61 0 3 92 39 10 50...

Отзывы: