Important operating notes

This device can be used by children aged 8 
and over, as well as by persons with reduced 
 physical, sensory or mental capabilities or 
with a lack of experience and knowledge, pro-
vided that they are supervised or have been 
 instructed on how to use the unit safely and 
that they understand the resulting risks. Chil-
dren must not be allowed to play with the unit.

Repairs may only be carried out by an 
expert.

Guarantee claims, warranty claims and ac-
ceptance of liability will be ruled out in the 
event of the following:

 

– Modifications to the device (including 

accessories),

 

– Using replacement and accessory parts 

 other than original Truma parts,

 

– Failure to follow the installation and  operating 

instructions.

The device’s operating permit, and conse-
quently also the vehicle’s operating permit in 
some countries, are also rendered void.

If only the cold water system is being oper-
ated without the boiler, the boiler also fills up 
with water. To avoid frost damage, the water 
in the boiler must be drained by operating the 
safety/drain valve, even if the boiler has not 
been used. Alternatively, two hot water-resist-
ant shut-off valves can be fitted upstream of 
the cold and hot water connection.

If the boiler is connected to a central water 
supply (rural or urban connection), a pressure 
reducer must be used, which will prevent 
pressures higher than 2.8 bar from occurring.

In Germany, the Truma Service Centre must 
 always be notified in the event of faults; in 
 other countries the respective service partners 
are available (see www.truma.com). 

Boiler Elektro (Electric Boiler) 

Operating instructions

Indholdsfortegnelse

Symbols used  ........................................................................  2
Model  ....................................................................................  2
Intended use  ..........................................................................  2

Operating instructions

Important operating notes

  ................................................  2

Filling the boiler

  ..................................................................  3

Draining the boiler

  .............................................................  3

Start-up

  ................................................................................  4

Maintenance

  .......................................................................  4

Disposal  .................................................................................  4

Technical data

  .....................................................................  5

Manufacturer’s Warranty
(European Union)

  ................................................................  5

Symbols used

Symbol indicates a possible hazard.

Note containing information and tips.

Model

Boiler Elektro (electric boiler) (BE 14)

Intended use

The Boiler Elektro (electric hot water generator) heats up wa-
ter using an electric heating element (230 V, 850 W). 

Содержание BE 14

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle Boiler Elektro ...

Страница 2: ...ater To avoid frost damage the water in the boiler must be drained by operating the safety drain valve even if the boiler has not been used Alternatively two hot water resist ant shut off valves can be fitted upstream of the cold and hot water connection If the boiler is connected to a central water supply rural or urban connection a pressure reducer must be used which will prevent pressures highe...

Страница 3: ...osed Lever horizontal position a The safety drain valve must be actuated regularly in order to prevent limescale deposits and to ensure that it is not blocked Figure 1 a Lever position Closed b Lever position Drain Turn on the hot water tap in the bathroom or the kitchen In the case of thermostatic or single lever mixer taps set to warm Switch on power to pump assembly main switch or pump switch L...

Страница 4: ...onal regulations and laws in Germany for example the End of life Vehicle Regulation must be observed In other countries the relevant regulations must be observed Troubleshooting guide Fault Cause Remedy Water not getting hot No operating voltage Operation without water overtemperature protec tion switching heating ele ment off Restore power supply Switch off wait for 10 minutes fill with water swi...

Страница 5: ...validity of the German Product Liability Act Produkthaftungsgesetz Neither does the voluntary Manufacturer s Warranty affects the Consumer s legally applicable claims for defects towards the seller in the relevant country of purchase In individual countries there may be warranties that can be issued by the relevant dealer official distributor Truma Partner In such cases the warranty can be impleme...

Страница 6: ...tes Trumas serviceafdeling eller en af vores autoriserede servicepartnere se www truma com Sørg for at have oplysninger om apparattype og serienummer se typeskiltet klar for hurtig behandling Vid fel kontakta Truma servicecenter eller någon av våra auktoriserade servicepartner se www truma com För snabb handläggning bör du ha aggregatets typ och serienummer se typskylten till hands Truma Gerätetec...

Отзывы: