Trueshopping
www.TrueShopping.co.uk
Page:
of 26
14
Operation
Adjustment switch
The adjustment switch is at the face panel of the machine,
each has eight steps. Set the desired welding current for the
type of metal being welded using the eight steps. Thinner
metals use lower current. Heavier metals use higher current.
Size of welding rod/thickness of metal
Amperage setting
1/16
14 swg
2.0mm
60-70A
12 swg
2.5mm
75-95A
1/8
10swg
3.25mm
100-140A
4.0mm
140-180A
5.0mm
190-250A
Overload light
If welding with large current for a long time and you exceed
the duty cycle, the overload lamp will light yellow and the
machine will stop working until it once again reaches a safe
temperature. When the overload lamp lights you must turn
the switch to “OFF” position and wait about 15 minutes, then
you can continue.