Trueheat TH28 Скачать руководство пользователя страница 8

Содержание TH28

Страница 1: ...ossible fire hazard Use only UL Listed Trueheat fireplace parts marked with the UL Listing Mark and the Trueheat name Use of other manufacturer s fireplace parts with your Trueheat fireplace system will void the Trueheat Warranty and may cause a possible fire hazard For proper operation of your Trueheat fireplace system refer to the Trueheat Opera tion Manual provided in the plastic bag around you...

Страница 2: ...nstallations IMPORTANT CONSIDERATIONS The Fireplace The fireplace should be installed on a solid continuous surface Do not install your fireplace on a floor covered with carpeting vinyl or similar soft combustible material However the fireplace may be installed directly on plywood particle or other solid combustible material The fireplace may be located practically anywhere in the room You should ...

Страница 3: ... one or two 30 off sets pair of elbows per fireplace chimney system Offsets may be desired to avoid plumbing wiring roof joists etc Never use more than two 30 offsets per system and never connect 2 or 3 elbows together to make a 60 or 90 offset Always secure the 4 elbow support straps to framing members of the structure The maximum offset distance is 8 ft To achieve an 8 ft offset you must use 4 4...

Страница 4: ...ney using sheet metal screws Note the sheet metal screw must not penetrate the center flue pipe of the chimney Do not install damaged chimney components If spacerclips ohouter pipe have become dislodged from thechimney straight or elbow sections then they must be repaired prior to installation In order todetermine how many and what size ofchimney sections that arerequired to gettothedesired height...

Страница 5: ...r TH36 inch fireplace and cap For TH42 Fireplace add Vt ft to the height shown Heights given indicate the total height of fireplace and chimney CHIMNEY HEIGHT CHIMNEY SECTIONS F12 10 F12 B P18 10 F18 8 F38 10 P36 8 F48 10 F48 8 10 6 1 1 ire 1 1 12 0 2 12 6 2 13 0 2 2 13 6 1 2 14 0 1 2 14 6 2 2 15 0 3 15 6 1 2 16 0 1 3 16 6 3 17 0 2 3 ire 1 3 18 0 1 3 18 6 2 3 19 0 4 19 6 1 3 20 0 1 4 20 6 4 2V 0 2...

Страница 6: ... the desired height From the Vertical Installation Chart a 22 ft 6 in installation re quires two F12 8 one F18 8 and four F48 8 chimney sections EXAMPLE B Let s say you are installing the fireplace in your family room Directlyabove the place where you would like to in stall the fireplace is a bedroom Therefore you want to offset the chimney to avoid the room In order to calculate the distance requ...

Страница 7: ...set 1 palr 30 elbows offsets 1 F36 8 Total overall chimney height required 21 ft Chimney components required to complete installation 3 FT 1 FT 8 FT 1 FT 21 FT OFFSET DISTANCE REQUIRED 12 INCHES REAR EDGE OF OBJECT TO BE AVOIDED T 8 FT Total height offset rise chimney components needed 21 ft 39 in 3 3 or 3 18 ft height From the Vertical Installation Chart Table 2 the sections required are 1 F12 8 ...

Страница 8: ...as line should be constructed of in iron pipe and the appropriate iron fittings The gas line can enter the fireplace from either side With a screwdriver and hammer remove the knockout from the outside wall of the fireplace If the fireplace is equipped with metal side panels in the firebox then remove the knockout in the side panel the same way Ifthe fireplace has refractory side panels then chisel...

Страница 9: ...and has no minimum or max imum length requirements HOUSE VENT IS M InlUIWd through Mttrior will ol tlnwtut PLASTIC TICS Is Haxhaaoto hovsowttand tUftiRQ codu SIARTINO COLLAR with t n thott motif tcrowt lo tocuro colUr 10 ftrtploco FIG 11 OUTSIDE COMBUSTION AIR HOOKUP FIG 12 OUTSIDE COMBUSTION AIR INSTALLATION METHODS 4ffll WPP m Flex Duct can be installed In any direction Installation of Outside A...

Страница 10: ...BE IN STALLED The model RJ roof joist shields must be installed at the roof joist level as shown in FIG 14 ForTH42 models the mod el RJ roof joist shields must be used for all installations Roof joist shields must be in stalled in accordance with FIG 14 If these installation guidelines are not followed you will void your TRUEHEAT warranty and may create a fire hazard MINIMUM OFFSET OF 4 INCHES MIN...

Страница 11: ...2 SHEET METAL SCREWS AFTER WIRING 3 PRONG RECEPTACLE WIRING DIAGRAM 1 ADDITIONAL REQUIREMENTS FOR MOBILE HOME INSTALLATIONS Trueheat Models TH28MG TH28MGF TH36MG and TH36MGF are UL Listed for use in Mobile Homes Mobile home Installations should be identical to permanent structure installations with the following exceptions and additional precautions WARNINQ CAUTION 1 NEVER INSTALL A FIREPLACE IN A...

Страница 12: ...MUST BE EMPLOYED FIG 16 ILLUSTRATES THE PROPER FIRESTOP THIMBLE INSTALLATION FOR CATHEDRAL CEILINGS BE SURE TO USE THE THIMBLE SHIELD EXTENSION AS WELL AS THE THIMBLE TUBE EXTENSION 12 ALWAYS COVER THE TOP OF THE CHIMNEY WITH PLASTIC BEFORE INSTALLATION OF THE CHIMNEY CAP AND FINAL PERMANENT INSTALLATION TO PREVENT RAIN AND DEBRIS FROM BLOWING IN THE CHIMNEY PRIOR TO THE INSTALLATION OF THE FINAL ...

Страница 13: ...and lift out of clips on the bottom outside corners of the doors When replacing doors place bottom door guide pin into hole of door clip and then slide top door guide pin outward and upwards into upper door clip hole For proper glass door operation see your Trueheat Owner s Manual FIG 17 FRONT FIG 18 REMOVING AND INSTALLING GLASS DOORS TO REMOVE Push spring clip up see arrow and pull doors out Ssr...

Страница 14: ...on of the TH42 use 91 2 inches in each direction and a 19 by 19 hole See FIG 19 This same procedure should be followed for each level that is to be penetrated Step 4 After cutting a hole in the last ceiling you are now ready to locate and cut the hole in the roof of the structure The roof hole can be located using a plumb line as shown in Step 3 However the length of the hole through the roof will...

Страница 15: ...wo holes 180 apart using drill bit less than 2 inches long and screw sections together WARNING BEVERY CAREFUL WHEN DRILLING HOLES IN THE OUTER PIPE NOTTO DRILL THROUGH THE STAINLESS STEEL FLUE FIG 22 MOUNT FIRESTOP SPACER IN THIS MANNER WITH ATTIC ABOVE CEIUNG MOUNT FIRESTOP SPACER IN THIS MANNER WITH ANOTHER ROOM ABOVE CEILING TABLE 5 PITCH MINIMUM ROOF OPENINGS FRAMING MEMBERS TH28 TH36 x 12 2x4...

Страница 16: ...ion Install the remaining chimney sections to the exterior of the structure Make sure the chimney extends a min of 3 ft above the roof and 2 ft above any portion of the roof within 10 ft Pull the flashing down over the chimney till it rests on the roof and mark the spot where the flashing overlaps the roof Remove the roofing in the area marked and slide the flashing under the roofing above the hol...

Страница 17: ... the desired material Drywall and plywood are two commonly used If you are finishing the face of the fireplace with combustible materials see FIG 25 If you are finishing the face of the fireplace with non combustible materials see FIG 26 WARNING COMBUSTIBLE MATERIALS MUST NEVER OVERLAP THE BLACK PAINTED PORTION OF THE FIREPLACE COMBUSTIBLE FACING MATERIAL TO THESE EDGES OF FIREPLACE COMBUSTIBLE FA...

Страница 18: ...ur fireplace is installed over a combustible floor then a non combustible hearth extension must be employed The hearth extension must be constructed as described in the Hearth Extension portion of this manual Your Trueheat Fireplace should now be ready for use Before starting your first fire make sure you have thoroughly read and understand your Trueheat1 Owners Manual We hope your Trueheat Firepl...

Страница 19: ...LEAvTfTT ENTERPRISES 6253 GUILDS AVENUE SAN DIEGO CA 92139 W19 267 0540 ...

Страница 20: ... y ...