3. Operation
3.1 General
C³V Series integrates two power supplies – constant voltage (CV) and constant
current (CC). These two power supplies exclusively operate, and outputs do not
exceed user-preset limit. CV or CC states are dependent on and limited by the
comparison between load conditions and C³V Series settings.
3.2 Description
C³V Series utilizes the Up and Down keys to set desired voltage and current outputs.
Real time voltage and current are displayed on the Display Meter. Pressing the Enter
key momentarily switches between different operation modes.
The V-LED and A-LED indicate the selected operation mode. The CC-LED indicates
that the power supply currently being in CC Output (Reading) mode.
3.3 Output (Reading) Mode & Setting mode
Output (Reading) Mode
Upon AC powering on the C³V Series, the unit automatically enters “Output (Reading)
Mode” and the green V-LED illuminates. The values shown on the Display Meter refer
to the last used data. Pressing the Enter key momentarily, you can read the voltage,
current (if a load was connected) and internal temperature. The outputs are controlled
by preset CC and CV values, as shown in the graph below.