control probe = return air
defrost probe = coil

DANFOSS ELECTRONIC TEMPERATURE CONTROL GENERAL SEQUENCE OF OPERATION

DANFOSS ELECTRONIC CONTROL FREEZER / GC WITHOUT DIGITAL DISPLAY
GENERAL SEQUENCE OF OPERATION

1.   Cabinet is plugged in.
  a.   Interior lights will illuminate on glass door models only. If the lights do not come on verify the light switch is in the “ON” 

position. Solid door cabinets may or may not have lights that may be controlled by the door switch.

  b.   Cabinet will start in a Defrost Cycle. The duration for defrost will be a minimum of 4 minutes and a maximum of 30 minutes.

2.   The Danfoss control is preprogrammed to initiate defrost every 4 hours of compressor run time.

If deemed necessary by the Danfoss control additional defrost may occur at unspecified times.  

  a.   At this time, the compressor and evaporator fan(s) will turn off and the evaporator coil heater and drain tube heater will be 

energized. Some cabinets may also change the rotation of the reversing condenser fan motor.

  b.   Once a preprogrammed temperature of the evaporator coil is reached, or 30 minutes,the Defrost Cycle will terminate and 

the 2 minute delay will occur.

  c.   After the 2 minute delay the compressor will restart.
  d.   The evaporator fans will remain off for an additional 3 minutes.

3. The Danfoss control will cycle the compressor and the evaporator fan(s) on and off together. 
  a.   The temperature control is sensing the discharge air temperature.
  b.   The temperature control should be set on the #4 or #5.  
  c.   The warmest setting is #1, the coldest is #9, and #0 is the off position.
  d.   The thermometer is designed to read and display a cabinet temperature not a product temperature.

This cabinet temperature may reflect the refrigeration cycle determined by the temperature control.
The most accurate temperature on a cabinets operation is to verify the product temperature.

Содержание TUC-27F

Страница 1: ...commercial freezer available You can expect many years of trouble free operation TABLE OF CONTENTS SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 INSTA...

Страница 2: ...l safety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion...

Страница 3: ...ST BE PROPERLY GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qual...

Страница 4: ...eed to be installed so the glass door does not receive any damage See image for bracket and shipping block removal NOTE KEYS FOR COOLERS WITH DOOR LOCKS ARE LOCATED IN WARRANTY PACKETS ELECTRIC INSTAL...

Страница 5: ...4 60 12 10 8 6 6 6 6 6 5 4 4 3 70 10 10 8 6 6 6 5 5 4 4 2 2 80 10 8 8 6 6 5 5 4 4 3 2 2 90 10 8 6 6 5 5 4 4 3 3 1 1 100 10 8 6 6 5 4 4 3 3 2 1 1 115Volts Distance In FeetTo Center of Load Amps 20 30...

Страница 6: ...H TRUE WILL NOT WARRANTY ANY UNITS THAT ARE CONNECTED TO AN EXTENSION CORD LOCATING A Remove louver from the front of cabinet see page 11 for louver grill removal reinstallation and backguard if appli...

Страница 7: ...diagonally B Install the desired number of shims making sure the slot of the shim is in contact with the threaded stem of the castor See image 2 C If more than one shim is used turn the slot at a 90 a...

Страница 8: ...from the floor for flat shelves C Shelves are oriented so that cross support bars are facing down D Place shelves on shelf clips making sure all corners are seated properly Shelf Clip Shelf Shelf Pil...

Страница 9: ...of the shelf clip to install 3 Shelf clip installation complete 4 DRAWER SET 2 REMOVAL Slide out drawer and locate white drawer retainer Push white drawer retainer towards drawer front panel Pull up o...

Страница 10: ...ng with the control could lead to service difficulties Should it ever become necessary to replace temperature control be sure it is ordered from your TRUE dealer or recommended service agent D Good ai...

Страница 11: ...mperature of the evaporator coil is reached 3 The temperature control may cycle the compressor and evaporator fan s on and off together a The temperature control is sensing the air temperature b The t...

Страница 12: ...s F Do not make more than 3 4 turn After making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to t...

Страница 13: ...ke note as to which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out te...

Страница 14: ...p freezers www truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 2...

Страница 15: ...TIME CLOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All r...

Страница 16: ...ical temperature control To adjust the defrost cycle time there is only one possible adjustment Once the cabinet has reach the design temperature pick the time of the day that you want the unit to def...

Страница 17: ...not a product temperature This cabinet temperature may reflect the refrigeration cycle of the Set Point and it s Differential The most accurate temperature on a cabinets operation is to verify the pro...

Страница 18: ...setting has been set correctly release the info button Wait 5 seconds for the display to show temperature See image 5 USING THE LAE ELECTRONIC CONTROL LOCKING AND UNLOCKING THE LAE CONTROLLER WHY Lock...

Страница 19: ...repeat prior steps and a temperature will appear ON Position TURNING THE GLASS DOOR MODEL LIGHTS ON AND OFF May need to unlock control WHY Light may be controlled by LAE Controller or interior light s...

Страница 20: ...mperature HOW TO CHANGE THE SET POINT STEP 1 To see the set point press and hold the Info button See image 1 STEP 2 While still holding the Info button press the Up or Down button to change the set po...

Страница 21: ...LAR TIME DEFROST TIM If controller is preprogrammed for TIM press and release the Manual Defrost button until dEF appears REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold...

Страница 22: ...me NOTE Depending on the version of control one of three parameters will appear ScL image 1a SPL image 1b MdL image 1c STEP 2 Push the Up button until dFt appears See image 2 STEP 3 Press and hold the...

Страница 23: ...utton and the Stand by button at the same time MdL will appear See image 1 STEP 2 Push the Down button until ScL appears See image 2 STEP 3 Press and hold the Info button to see the readout scale See...

Страница 24: ...the T3 probe If probe T3 is not activated t3 will not appear of the display DISPLAYING TEMPERATURE PROBES T1 T2 T3 WHY To display temperature probe readings in different locations of the cabinet DISPL...

Страница 25: ...A N G E P N S U B J E C T T O C H A N G E N R S U B J E C T T O C H A N G E R D S U B J E C T T O C H A N G E D M S U B J E C T T O C H A N G E M D S U B J E C T T O C H A N G E D D S U B J E C T T O...

Страница 26: ...e compressor and evaporator fan s will turn off and the evaporator coil heater and drain tube heater will be energized Some cabinets may also change the rotation of the reversing condenser fan motor b...

Страница 27: ...gh the Condenser continuously along with dust lint grease etc A dirty Condenser can result in NON WARRANTEED part Compressor Failures Product Loss and Lost Sales Proper cleaning involves removing dust...

Страница 28: ...water will suffice 8 STEPS THAT CAN HELP PREVENT RUST ON STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s pa...

Страница 29: ...aced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly throughTRUE All claim...

Отзывы: