IMPORTANT WARRANTY  INFORMATION 

Condensers accumulate dirt and require cleaning every 30 days. 
Dirty condensers result in compressor failure, product loss, and lost 
sales, which are not covered by warranty.

If you keep the Condenser clean you will minimize your service 
expense and lower your electrical costs. The Condenser requires 
scheduled cleaning every thirty days or as needed.

Air is pulled through the Condenser continuously, along with dust, 
lint, grease, etc.

A dirty Condenser can result in NON-WARRANTEED part & 
Compressor Failures, Product Loss, and Lost Sales. 

Proper cleaning involves removing dust from the Condenser. By using 
a soft brush, or vacuuming the Condenser with a shop vac, or using 
CO2, nitrogen, or pressurized air.
If you cannot remove the dirt adequately, please call your refrigera-
tion service company. 

On most of the reach-in units the condenser is accessible in the 
rear of the unit. You must remove the cabinet grill to expose the 
Condenser. 

The Condenser looks like a group of vertical fins. You need to be able 
to see through the condenser for the unit to function at maximum 
capacity. Do not place filter material in front of condensing coil. This 
material blocks air-flow to the coil similar to having a dirty coil.

THE CLEANING OF THE CONDENSER IS NOT 
COVERED  BY THE WARRANTY!

HOW TO  CLEAN THE  CONDENSER:

1.   Disconnect the 

electrical power to 
the unit.

2.   Remove the louvered 

grill.

3.   Vacuum or brush the 

dirt, lint, or debris 
from the finned 
condenser coil.

4.   If you have a significant dirt build up you can blow out the 

condenser with compressed air.  

 

(CAUTION MUST BE USED TO AVOID EYE INJURY. 
EYE PROTECTION IS RECOMMENDED.)

5.   When finished be sure to replace the louvered grill. The grill 

protects the condenser.

6.   Reconnect the electrical power to the unit.

If you have any questions, please call TRUE Manufacturing at 636-240-
2400 or 800-325-6152 and ask for the Service Department. Direct 
to Service Department 1(855)372-1368. Service Department 
Availability Monday-Thursday 7:00 a.m. to 7:00  p.m., Friday 7:00 a.m. 
to 6:00 p.m. and Saturday 8:00 a.m. to 12:00 p.m. CST.

Condensing Unit

Airflow

Condenser

Содержание TCGG-36-LD

Страница 1: ...ATION MANUAL tcgg curved glass deli case TABLE OF CONTENTS SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 INSTALLATION Ownership Uncrating How to Connect to Electricity 3 Wire Gauge Chart 4 Locating and Leveling 5 Sealing Cabinet to the Floor 6 SETUP Standard Accessories 7 OPERATION Startup 9 Mechanical Temperature Controls Sequence of Operation 10 M...

Страница 2: ...utions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due to puncture of refrigerant tubing follow handling instructions carefully Flammable refrigerant used CAUTION Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for...

Страница 3: ... GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded If the outlet is a standard 2 prong outlet it is your personal respon sibility and obligation to have it replaced with the properly grounded wall outle...

Страница 4: ...by a special cord or assembly available from the manufacturer or its service agent Lamps must be replaced by identical lamps only Appliance tested according to the climate classes 5 and 7 temperature and relative humidity ELECTRICAL INSTRUCTIONS A Before your new unit is connected to a power supply check the incoming voltage with a voltmeter If anything less than 100 of the rated voltage for opera...

Страница 5: ... 6 6 6 6 6 5 4 4 3 70 10 10 8 6 6 6 5 5 4 4 2 2 80 10 8 8 6 6 5 5 4 4 3 2 2 90 10 8 6 6 5 5 4 4 3 3 1 1 100 10 8 6 6 5 4 4 3 3 2 1 1 115 Volts Distance In Feet To Center of Load Amps 20 30 40 50 60 70 80 90 100 120 140 160 2 14 14 14 14 14 14 14 14 14 14 14 14 3 14 14 14 14 14 14 14 14 14 14 14 12 4 14 14 14 14 14 14 14 14 14 12 12 12 5 14 14 14 14 14 14 14 12 12 12 10 10 6 14 14 14 14 14 14 12 12...

Страница 6: ...want to install an exhaust fan WARNING WARRANTY IS VOID IF VENTILATION IS INSUFFICIENT B Proper leveling of your TRUE cooler is critical to operating success for non mobile models Effective condensate removal and door operation will be effected by leveling C The cooler should be leveled front to back and side to side with a level D Ensure that the drain hose or hoses are positioned in the pan E Fr...

Страница 7: ... caulking material C When applying a mastic thoroughly clean both the cabinet and floor of dirt and grease Draw an outline of the cabinet on the floor Raise and block the front side of the cabinet Apply a bead of mastic to the floor 1 2 1 3 cm inside the outline drawn Lower the cabinet Raise and block the rear side of the cabinet Apply the bead of mastic lower the cabinet NOTE Asphalt floors are v...

Страница 8: ...lf supports wrapped in micro foam and install teeth end into stainless pilasters located on interior walls Adjust to desired height matching right and left pairs See Figure 1 2 C Locate the stainless steel shelf and install with product stop towards the front of the cabinet Side flaps should overlap shelf support be sure to fit shelf support tip into front slot of shelf See Figure 3 5 D Plug shelf...

Страница 9: ...ooks of light assembly on two shelf supports left and right slide assembly forward until it seats in front notch of shelf support Then the stainless steel shelf can be installed on the shelf supports See figure 3 WIRE SHELF SUPPORT BRACKETS E Install rear brackets by sliding end hooks over rear notch of shelf support See figure 4 F Locate wire shelves install top shelf first With the front lip tra...

Страница 10: ...essive tampering with the control could lead to service difficulties Should it ever become necessary to replace temperature control be sure it is ordered from your TRUE dealer or recommended service agent D Good air flow in your TRUE unit is critical Be careful to load product so that it neither presses against the back wall nor comes within four inches of the evaporator housing Refrigerated air o...

Страница 11: ... an evaporator fan motor 3 The temperature control may cycle the compressor and evaporator fan s on and off together a The temperature control is sensing the evaporator coil temperature b The temperature control should be set on the 4 or 5 c The warmest setting is 1 the coldest is 9 and 0 is the off position d The thermometer is designed to read and display a cabinet temperature not a product temp...

Страница 12: ...er making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow the Altitude Correction Table to the right WARMER COLDER 60 30 45 40 35 50 55 15 20 25 10 5 We advise to make a mechanical temperature control adjustment only for a high altitude location Compressor Terminals Gr...

Страница 13: ... which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temperatures will be colder than when the controller functions closer to sea level STEP 5 For high elevation installations it may be necessary to warm up the set points To make the adjustment insert the appropriate ...

Страница 14: ... truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 8000 258 9000 294 10 000 330 ...

Страница 15: ... flip the white tabs back toward the center of the Defrost Timer STEP 3 TRUE recommends a 60 minute defrost cycle three times per day DEFROST TIMER DEFROST TIME CLOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All Deli Cabinets will require routine defrost Yo...

Страница 16: ...arefully slide out tube connections are flexible STEP 4 Clean off accumulated dirt from condensing coil with a stiff bristle brush STEP 5 Lift cardboard cover above fan at plastic plugs and carefully clean condenser coil and fan blades STEP 6 After brushing condenser coil vacuum dirt from coil and interior floor STEP 7 Replace cardboard cover Carefully slide compressor assembly back into position ...

Страница 17: ...xpose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in front of condensing coil This material blocks air flow to the coil similar to having a dirty coil THE CLEANING OF THE CONDENSER IS NOT COVERED BY THE WARRANTY HOW TO CLEAN THE CONDENSER 1 Disconnect the e...

Страница 18: ... STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and plastic scouring pads Step 2 tells you how to find the polishing marks 2 CLEANING ALONG THE POLISH LINES Polishing lines or grain are visible on some stainless steels Always scrub parallel to visible lines o...

Страница 19: ...bulb Please be aware of your local ordinances in disposing old bulbs These bulbs should be disposed in a safe and correct manner FOR ADDITIONAL MAINTENANCE INSTRUCTION PLEASE VISIT THE MEDIA CENTER AT WWW TRUEMFG COM There are light bulbs located under the cabinet shelving Shelving light bulb Inside the cabinet and toward the ceiling in front of the evaporator coil you will find a florescent blub ...

Страница 20: ...must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly through TRUE All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect In case of warranty compressor the c...