............ www.truemfg.com ............
True Food Service Equipment, Inc.
3
3
Before your new display case is connected to a power
supply, check the incoming voltage with a voltmeter.
If anything less than 100% of the rated voltage for
operation is noted, correct immediately.
Have the circuit checked by a qualified electrician to
make sure it is properly grounded.
The display case should always be use it’s own individual
electrical circuit, which has a voltage rating that matches
the rating plate.
This provides the best performance and also prevents
overloading building wiring circuits which could cause a
fire hazard from overheated wires.
For models with Optional 12" (30.5 cm) cord.
The power cord of this appliance is equipped with a
grounding plug which mates with a standard grounding
wall outlet to minimize the possibility of electric shock
hazard from this appliance.
Have the circuit checked by a qualified electrician to
make sure it is properly grounded.
If the outlet is a standard 2-prong outlet, it is your
personal responsibility and obligation to have it replaced
with the properly grounded wall outlet.
The display case should always be plugged into it’s own
individual electrical circuit, which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading building wiring circuits which could cause a
fire hazard from overheated wires.
Never unplug your display case by pulling on the power
cord. Always grip plug firmly and pull straight out from
the outlet.
Repair or replace immediately all power cords that have
become frayed or otherwise damaged. Do not use a cord
that shows cracks or abrasion damage along its length or
at either end.
When removing the display case away from the wall, be
careful not to roll over or damage the power cord.
HOW TO CONNECT ELECTRICITY
Hard wiring is required on standard "Dry" Display Cases.
Optional 12" (30.5 cm) corded model available, factory installed only
(exterior scale receptacle will not be included with this option).
WARNING!
NOTE
Applies to models ordered with 12" power
cord, hard wired models do not use this
receptacle.
USE OF ADAPTER PLUGS
NEVER USE AN ADAPTER PLUG! Because of potential safety hazards under certain conditions, we strongly recommend
against the use of an adapter plug.
SAFETY INFORMATION
NEMA plugs
TRUE uses these types of plugs. If
you do not have the right outlet have
a certified electrician install the correct
power source.
115/60/1
NEMA-5-15R
The incoming power source to the cabinet including any adapters used must have the adequate power available and
must be properly grounded. Only adapters listed with UL should be used.