background image

16 

4.5 TAKING CROSS SECTION PHOTOS 

 

 
After the terminal returns to its home position, open 
the safety cover. 
 
1. Take the clamp out.  
2. Place it on the clamp holding stand. 
Align the clamp fitting hole with the cylindrical pin  
 
 
 
 
 
 

 

 

Each type of clamp is designed to have 2 holes on 

its body: 
● 

Fixing hole:

 Used when placing the clamp on the 

transfer unit. 
● 

Fitting hole:

 Used when placing the clamp on the 

clamp holding stand. 
 
 
 
 
 
 

 

3. Adjust X and Y knobs so that the terminal cross 
section is at the center of the image. 
● X knob: Move left and right 
● Y knob: Move up and down 
 
Adjustment range for X and Y knobs: ±7.5mm. 
 
 
 
 
 

 

 
 

 
4. Adjust the camera focus. 
 
5. Start etching the surface.  
6. Take a cross section photo. 
 
 
 

Clamp Holding Stand 

Cylindrical Pin 

Y knob 

Y knob 

X knob 

Fitting hole 

Fixing hole 

Содержание CS07

Страница 1: ...Cross Section Monitor CS07 Version 2 0 24 March 2022 OPERATION MANUAL...

Страница 2: ...1 UPDATED HISTORY Version Date of Issue Updated by Remark Ver 1 0 12 Apr 2021 Iwatake 1st Edition Ver 2 0 24 Mar 2022 Yanagawa USB camera specification change Compatible with FW Ver1 03...

Страница 3: ...A 20 5 4 DISPOSING THE CUTTING DEBRIS 21 6 TROUBLE SHOOTING 22 7 BIG WIRE CROSS SECTION 24 7 1 BIG WIRE CUTTING OPTIONAL COMPONENTS 24 7 2 INSTALLING THE VACUUM DEVICE 25 7 3 INSTALLING THE AUXILIARY...

Страница 4: ...refer to it for the safe and proper use of the device WARNING DEFINITIONS Be sure to read these guidelines and precautions before handling the equipment The safety precautions are classified into 2 c...

Страница 5: ...rue Soltec or other qualified service personnel 5 Unplug the machine and other surrounding devices from AC outlet before installing or connecting CS07 to other devices 6 Do not let liquids or foreign...

Страница 6: ...range 20 85 Do not place it near sources of heat or fire Do not place it near salt oil or corrosive gas Avoid places where power leakage vibration and static electricity are present Do not place it i...

Страница 7: ...Unit USB Camera USB cable Microscope lens Ring LED Calibration Stand Micro Gauge Power cord Male to male USB cord Standard Clamp Sandpaper 1200 25pcs Cutting wheel 10pcs Cross Section Analysis Softwar...

Страница 8: ...ART button at grinding mode 5 Ring LED Provide light for USB camera Adjust the Led brightness via the LCD screen 6 USB Camera Connect with your computer to take cross section photos 7 Microscope lens...

Страница 9: ...Hold the camera while loosening this screw 3 Air flow Connect with an air tube to let the air into the main unit 4 Metal debris tray Hold terminal dust debris after being cut Periodically clean this...

Страница 10: ...6 Increase the brightness of Ring LED USB camera Range 1 16 7 Decrease the brightness of Ring LED USB camera Range 1 16 8 Increase the brightness of box LED Position checking camera Range 1 16 9 Decr...

Страница 11: ...down 3 Rotate the screw clockwise to tighten the terminal firmly At Clamp Transfer Unit 4 Pull the lever down 5 Place the clamp on the transfer unit Align the clamp fixing hole with the cylindrical p...

Страница 12: ...o the cutting and grinding wheel Choose a proper V groove depending on the terminal size Applicable wire size for reference Small V groove Width 1 3mm Height 0 4mm AWG24 AWG32 Medium V groove W 2 7mm...

Страница 13: ...rizontal line or not based on these lines Refer to CS07HI operation manual for details 3 Loosen the fixing screw by rotating it counterclockwise This screw prevents the position adjusting dial from mo...

Страница 14: ...the cutting position to the clamp surface is approx 0 6 0 7mm After grinding this distance is approx 0 5mm The fixing screw must be tightened firmly before operation Otherwise it may cause damage to t...

Страница 15: ...keep moving to the right to have the terminal ground Finally it returns to the home position again After the sample is cut if you want the transfer unit to return to its home position immediately pres...

Страница 16: ...e right and grind the terminal surface When it is complete the transfer unit will automatically return to its home position While grinding the terminal if you want the transfer unit to return to its h...

Страница 17: ...y Fixing hole Used when placing the clamp on the transfer unit Fitting hole Used when placing the clamp on the clamp holding stand 3 Adjust X and Y knobs so that the terminal cross section is at the c...

Страница 18: ...ting screen appears 2 At Slide Clamper press Right button The tranfer unit starts moving to the right Turn off the power of CS07 3 Open the metal protective cover by sliding it to the left while holdi...

Страница 19: ...power of CS07 Press HOME button to move the transfer unit to its home postion Setting is completed 5 2 REPLACING THE SANDPAPER 1 Remove the clamp from the tranfer unit Close the safety cover On LCD o...

Страница 20: ...cker removers or similar tools to clean and remove the remaining glue completely 5 Firmly attach a new sandpaper to the grinding disc so that there are no wrinkles and no part can curl off 6 Return th...

Страница 21: ...Open the metal protective cover by sliding it to the left while holding the metal knob red circle Use a brush or similar tools to wipe all the cutting dust into the hole below the cutting wheel 4 Aft...

Страница 22: ...21 5 4 DISPOSING THE CUTTING DEBRIS After cutting the terminals their matting sections will fall into the metal debris tray Please clean this tray periodically once a day if possible Metal Debris Tray...

Страница 23: ...g wheel flange and check if the cutting disc is installed correctly The axis of the motor may have trouble Please contact us or our local sales agencies for inspection The grinding disc is loose The g...

Страница 24: ...r supply may be broken Use a tester to check if the voltage is output at the AC jack of the LED If the voltage is output the lights on the LED may be broken Please contact us or our local sales agenci...

Страница 25: ...ithout grinding CS07 automatically recognizes and switches to big wire cutting mode based on the clamp placed on the transfer unit Appicable wire range AWG10 AWG1 0 Distance from the cutting and grind...

Страница 26: ...llowing items to the main unit a Air tube b Power cable for vacuum unit c Duct hose 2 Open the vacuum unit by unlocking 3pcs individual locks red circles 3 Loosen the screw red circle Then pull the me...

Страница 27: ...n the metal plate to its original location Tighten the screw to fix the bag 6 Close the vacuum box and lock it again Place the vacuum box at well ventilated locations Do not block the air vent of the...

Страница 28: ...ry lens Rotate the auxiliary lens clockwise to attach it to the camera Camera working distance will become longer after installing the auxiliary lens It is necessary to raise the camera up further fro...

Страница 29: ...s into the clamp 1 Pull the clamp lever up red frame 2 Place the sample into the V groove of the clamp The terminal should be vertical above photo not bending to the left right or up down 3 Push the l...

Страница 30: ...herefore do not rotate the screw too much At Clamp Transfer Unit Pull the lever down Place the clamp on the transfer unit Release the lever 6 Change the cutting position if necessary Refer to 4 2 Adju...

Страница 31: ...anel big wire cutting mode Large is automatically recognized Check if cutting mode is activated or not Activated Deactivated If the cutting mode is not activated touch Cutting button It will switch to...

Страница 32: ...y Fixing hole Used when placing the clamp on the transfer unit Fitting hole Used when placing the clamp on the clamp holding stand 3 Adjust X and Y knobs so that the terminal cross section is at the c...

Страница 33: ...to the safety cover All the cutting dust will be stored in the vacuum bag inside the vacuum unit Dispose this metal dust following your local guidelines and regulations 1 Remove the vacuum bag by pull...

Страница 34: ...longitudinal cutting mode based on the type of clamp that is being used At longitudinal cutting mode operator manually moves the terminal close to the grinding wheel via controlling the LCD panel The...

Страница 35: ...ears 2 At Slide Clamper select Right button The transfer unit will move to the right Turn off the power of CS07 3 Open the metal protective cover by sliding it to the left while holding the metal knob...

Страница 36: ...the cutting wheel to the arbor Then mount the flange to the wheel firmly by rotating the screw counterclockwise This is a reverse screw 8 Return the metal protective cover to its original location Tur...

Страница 37: ...ight and leans back on the fixing block black This block will prevent the terminal from bending during the grinding process 2 Longitudinal cutting clamp is designed to hold the terminal mating section...

Страница 38: ...s Each clamp has 2 holes on its body Fixing hole Used when placing the clamps on the transfer unit Fitting hole Used when placing the clamps on the clamp holding stand 5 Adjust the cutting position Th...

Страница 39: ...At this position operators will control the LCD screen to move the terminal close the wheel a little at a time Check the camera while moving the terminal a Press and hold button to move the terminal c...

Страница 40: ...e the terminals a certain distance to the left each time you press it one step at a time The moving range that the terminal will move each time you press the button Setting range 0 02 0 1mm 5 After fi...

Страница 41: ...g hole Used when placing the clamps on the transfer unit Fitting hole Used when placing the clamps on the clamp holding stand 3 Adjust X and Y knobs so that the terminal cross section is at the center...

Страница 42: ...Operating Temperature 5 40 Humidity 0 90 RH No dew no condensation Dimensions W500 x D522 x H693mm Weight Approx 50kg Power AC100V 240V 50 60Hz 9 2 STANDARD LENS SPECIFICATIONS Magnification 0 7X 0 45...

Страница 43: ...ls No of effective pixels h x v 1280 x 1024 pixels Pixel size 3 6 m Frame rate 25 Exposure time 0 037ms 10122ms Power consumption 0 3W 0 8W Device temperature during operation 0 55 Humidity No condens...

Страница 44: ...res are caused by reasons attributing to customers such as improper operation they are not covered by the warranty even if it is still within the warranty period True Soltec shall make the judgement E...