True Manufacturing Company TMW TMW-36F Скачать руководство пользователя страница 5

............ www.truemfg.com ............

True Food Service Equipment, Inc.

3

3

The power cord of  this appliance is equipped with a 3-
prong (grounding) plug which mates with a standard 3-
prong (grounding) wall outlet to minimize the possibility 
of  electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified 
electrician to make sure the outlet is properly grounded.
If  the outlet is a standard 2-prong outlet, it is your 
personal responsibility and obligation to have it replaced 
with the properly grounded 3-prong wall outlet.
The unit should always be plugged into it’s own 
individual electrical circuit, which has a voltage rating 
that matches the rating plate.
This provides the best performance and also prevents 
overloading building wiring circuits which could cause a 
fire hazard from overheated wires.
Never unplug your freezer by pulling on the power cord.  
Always grip plug firmly and pull straight out from the 
outlet.
Repair or replace immediately all power cords that have 
become frayed or otherwise damaged. Do not use a cord 
that shows cracks or abrasion damage along its length or 
at either end.

When removing the freezer away from the wall, be 
careful not to roll over or damage the power cord.

IMPORTANT ELECTRICAL SAFETY INFORMATION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this appliance must be properly grounded.

WARNING!

USE OF EXTENSION CORDS / ADAPTER PLUGS

NEVER USE AN EXTENSION CORD!  NEVER USE AN ADAPTER PLUG! 

Do not use adapter plugs or extension leads as these 

can cause safety issues and early failure of electrical components.  The use of adapters and extension cords will invalidate 
your warranty.

WARNING

Compressor warranties are void if compressor burns out due to low voltage.

WARNING

Power supply cord ground should not be removed!

NOTE

To reference wiring diagram - Remove lower rear grill.  Wiring diagram is positioned on the inside cabinet wall.

SAFETY INFORMATION

Содержание TMW TMW-36F

Страница 1: ...L FAX 636 272 7546 800 325 6152 Parts Department 800 424 TRUE Parts Department FAX 636 272 9471 TABLE OF CONTENTS Safety Information Safety Precautions 1 Proper Disposal 2 Connecting Electricity 3 Ada...

Страница 2: ...oilage Of Products In Your Refrigerator Freezer Is NOT Covered By Warranty In Addition To Following Recommended Installation Procedures You Must Run The Refrigerator Freezer 24 Hours Prior To Usage Tr...

Страница 3: ...area NOTE Any servicing warranty repairs or maintenance should be carried out by qualified personnel failure to do so could be dangerous and may invalidate your warranty Unplug the freezer before cle...

Страница 4: ...unit is located there will be officially approved ways of disposing of your used equipment It is important that care is taken in disposing of used refrigerators or freezers Before You Throw Away Your...

Страница 5: ...p plug firmly and pull straight out from the outlet Repair or replace immediately all power cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage al...

Страница 6: ...Mole Grips Phillips Head Screwdriver Spirit Level REQUIRED TOOLS Step 1 The following procedure is recommended for uncrating the unit A Remove the outer packaging by pulling tri wall nails from skid R...

Страница 7: ...of the leg must make firm contact with the rail Unit leveling Four leveling shims have been provided for leveling castored units positioned on uneven floors Shims must be positioned between rail end...

Страница 8: ...e cabinet wall ELECTRICAL INSTRUCTIONS LEVELING Step 4 Securing Castors A Set unit in its final location Be sure there is adequate ventilation in your room Under extreme heat conditions 100 F 38 C you...

Страница 9: ...it is disconnected or shut off wait five minutes before starting again RECOMMENDATION Before loading product we recommend you run your True unit empty for two to three days This allows you to be sure...

Страница 10: ...nnect unit to power and check to see if condensing unit is running MAINTENANCE CARE CLEANING Condensers accumulate dirt and require cleaning every 30 days Dirty condensers result in compressor failure...

Страница 11: ...an when the controller functions closer to sea level D For high elevation installations it may be necessary to warm up the set points To make the adjustment insert the appropriate tool in each adjustm...

Страница 12: ...ing marks 2 Cleaning along the polish lines Polishing lines or grain are visible on some stainless steels Always scrub parallel to visible lines on some stainless steels Use a plastic scouring pad or...

Страница 13: ...round the top of the cabinet simply come off with no tools required This is for easier cleaning Please see figure 1 NOTE The use of stainless steel cleaners or other such solvents is not recommended o...

Отзывы: