True Manufacturing Company TBB-1-B Скачать руководство пользователя страница 13

............ www.truemfg.com ............

True Food Service Equipment, Inc.

11

11

DANFOSS ELECTRONIC TEMPERATURE CONTROL

GENERAL SEQUENCE OF OPERATION

YOUR TRUE GLASS & PLATE CHILLER MAY USE 
AN ELECTRONIC CONTROL - 115V/60HZ ONLY

IF YOUR CABINET IS PRODUCED WITH AN ELECTRONIC CONTROL, THERE MAY BE 

UP TO A 20 MINUTE DELAY WHEN CABINET IS PLUGGED IN.

If the serial number on your cabinet is higher than listed below, it was produced with 

an electronic control. 

1. Cabinet is plugged in.

a. Interior lights will illuminate of Glass Door Models only. If lights do not come on verify the light switch is in the 

“ON” position.  Solid door cabinet may or may not have lights that may be controlled by the door switch.

b. Cabinet will start in a Defrost Cycle.

2. During the initial Defrost Cycle, the evaporator fan(s) and the compressor will remain off for a minimum of 4 

minutes.

a. After the Defrost Cycle there will be a 2 minute delay.

b. After the 2 minute delay the compressor will start.

c. The evaporator fans will remain off for an additional 3 minutes.

3. The Danfoss  control will cycle the compressor and the evaporator fan(s) on and off together. 

a. The temperature control is sensing the discharge air temperature.

b. The temperature control should be set on the #4 or #5.  

c. The warmest setting is #1 and #0 is the off position.

d. The thermometer is designed to read and display a cabinet temperature not a product temperature.  This cabinet 

temperature may reflect the refrigeration cycle determined by the temperature control. The most accurate 

temperature on a cabinets operation is to verify the product temperature.

4. The Danfoss control is preprogrammed to initiate defrost every 4 hours of compressor run time.  

a. At this time the compressor and evaporator fan(s) will turn off and the evaporator coil heater and drain tube 

heater will be energized.  Some cabinets may also change the rotation of the reversing condenser fan motor.

b. Once a preprogrammed temperature of the evaporator coil is reached, the Defrost Cycle will terminate and the 2 

minute delay will occur.

c. After the 2 minute delay the compressor will restart.

d. The evaporator fans will remain off for an additional 3 minutes.

T-24-GC / T-24-GC-S

S# 7721857

T-36-GC / T-36-GC-S

S# 7218795

T-50-GC / T-50-GC-S

SN 7147406

Содержание TBB-1-B

Страница 1: ...Beer Problems 15 Changing CO2 Gas Cylinder 16 Cleaning Bar System 17 Cleaning the Condenser 18 Important Warranty Information 19 Stainless Steel Equipment Care Cleaning 20 21 Lightbulb Replacement 22...

Страница 2: ...www truemfg com True Food Service Equipment Inc...

Страница 3: ...rongly recommend that any servicing be preformed by a qualified individual Unplug the refrigerator before cleaning and making repairs Setting temperature controls to the 0 position does not remove pow...

Страница 4: ...s in place so that children may not easily climb inside Refrigerant Disposal Your old refrigerator may have a cooling system that uses Ozone Depleting chemicals If you are throwing away your old refri...

Страница 5: ...ords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When removing the refrigerator away from the wall be careful...

Страница 6: ...iately file a claim with the freight carrier if there is damage B Move your unit as close to the final location as possible before removing the wooden skid C Remove door bracket on swinging glass door...

Страница 7: ...ditions 100 F 38 C you may want to install an exhaust fan WARNING Warranty is void if ventilation is insufficient B Proper leveling of your TRUE cooler is critical to operating success for non mobile...

Страница 8: ...de the front door so it is centered on the cabinet The door can not be removed unless it is centered See image 1 for door channel openings and image 2 for centering door Three Door Units Slide the mid...

Страница 9: ...5 4 4 3 2 40 10 8 8 6 6 5 5 4 4 3 2 2 45 10 8 6 6 6 5 4 4 3 3 2 1 50 10 8 6 6 5 4 4 3 3 2 1 1 Wire Gauge for 2 Voltage Drop in Supply Circuits 230 Volt Distance In Feet To Center of Load Amps 20 30 4...

Страница 10: ...Level cabinet Step 3 Draw an outline on the base on the floor Step 4 Raise and block the front side of the cabinet Step 5 Apply a bead of NSF Approved Sealant see list below to floor on half inch insi...

Страница 11: ...ed on the inside cabinet wall ELECTRICAL INSTRUCTIONS On direct draws the drain is located at the front of the cabinet To plumb in the drain connect 3 4 2cm P V C pipe to the 3 4 2cm barbed fitting su...

Страница 12: ...or recommended service agent D Good air flow in your TRUE unit is critical Be careful to load product so that it neither presses against the back wall nor comes within four inches of the evaporator h...

Страница 13: ...he Danfoss control will cycle the compressor and the evaporator fan s on and off together a The temperature control is sensing the discharge air temperature b The temperature control should be set on...

Страница 14: ...e tool in each adjustment screw and turn 1 4 of a revolution clockwise to the right This procedure will adjust both the cut in and cut out about 2 F warmer STEP 5 Make sure to reconnect the pink wire...

Страница 15: ...ded rear pegs with holes in line with those desired in front Insert as far as possible and maneuver front pegs in place SHELF INSTALLATION BIN DIVIDER INSTALLATION NOTE Divider positioned in front of...

Страница 16: ...gulators to ensure applied pressure remains constant Keep equipment in good repair Do not agitate the kegs unnecessarily If excessive agitation occurs allow kegs to settle for 1 to 2 hours before tapp...

Страница 17: ...improperly Faucet in bad or worn condition Kinks dents twists or other obstructions in line Traps in beer lines Beer too warm in kegs or lines Too much pressure Creeping gauge causing too much pressu...

Страница 18: ...the pressure release valve on the body of the tap 10 Tap barrel at D with valve C open NOTE Don t lay CO2 cylinders flat Don t drop CO2 cylinders It requires 1 2 pound CO2 to dispense 1 2 barrel of be...

Страница 19: ...Use small brush to clean beer faucet parts fig 2 4 Rinse parts thoroughly 5 Fill pump bottle with DBK solution 6 Attach hose from pump bottle to beer column tap outlet be sure rubber gasket is in plac...

Страница 20: ...essor assembly to frame rails and carefully slide out tube connections are flexible STEP 4 Clean off accumulated dirt from condensing coil with a stiff bristle brush STEP 5 Lift cardboard cover above...

Страница 21: ...to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material in...

Страница 22: ...ls Use a plastic scouring pad or soft cloth when you cannot see the grain 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlori...

Страница 23: ...ssion is applied by rubbing in the direction of the polished lines for stubborn stains and discoloring D Easy off and De Grease It oven aid are excellent for removals on all finishes for grease fatty...

Страница 24: ...d correct manner WARNING When replacing a light bulb make sure power to the unit is either turned off or unplugged LIGHT BULB REPLACEMENT IDL INTEGRATED DOOR LIGHTING Remove the lampshield to reveal t...

Страница 25: ...er must also be the same capacity as the drier being replaced 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for l...

Отзывы: