ELEVATION SYSTEM OVERVIEW
(CONT.)
How this feedback is displayed varies with different models
and different consoles:
11
Note: See TRUE Dealer Portal for older model elevation values
Treadmill Series
Digital Value
Notes
CS 500, 550, 800 &
ES900 with
Touchscreen
With decline foot
14000 - 16000
At zero incline the incline digital value
displayed in calibration mode reads approx.
14000 - 16000. The DC voltage across the
orange and blue wires of the potentiometer
should read approx. 4.47 . As the treadmill
inclines, the displayed value increases while
the VDC decreases.
CS 500, 550, 800 &
ES900 with
Touchscreen
No decline foot
6500 - 8500
At zero incline the incline digital value
displayed in calibration mode reads approx.
6500-7500. The DC voltage across the
orange and blue wires of the potentiometer
should read approx. 4.47 . As the treadmill
inclines, the displayed value increases while
the VDC decreases.
CS 550/800 & PS
series with
11"
console
28
At zero incline the incline digital value
displayed in calibration mode reads approx.
28. The DC voltage across the black and
white wires(TPS series) or (orange and blue
on TCS series) of the potentiometer should
read approx. 4.47 VDC . As the treadmill
inclines, the displayed value increases while
the VDC decreases
CS 500,LC series,
PS series with
2
Window
228
At zero incline the incline digital value
displayed in calibration mode reads approx.
228. The DC voltage across the orange and
blue wires of the potentiometer should read
approx. 4.47 VDC. As the treadmill inclines,
the displayed value decreases while the VDC
decreases.
Tread Service Manual - July 2011