True Blue Power, Wichita, KS
REV. B February 11, 2014
15
Manual Number 9018067
SECTION 5
CONFORMANCE
5.1
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS
No periodic scheduled maintenance or calibration is necessary for continued airworthiness of the TI250
series Static Inverter. If the unit fails to perform to specifications, the unit must be removed and serviced
by Mid-Continent Instruments and Avionics or their authorized designee.
5.2
ENVIRONMENTAL QUALIFICATION STATEMENT
PART NUMBER: 6430250-( ) series
MODEL NUMBER: TI250
NOMENCLATURE: Static Electrical Power Inverter
TSO NUMBER:
C73
MANUFACTURERS SPECIFICATIONS: Test Specification (TS)
512, Test Data Sheet (TDS) 512
QUALIFICATION STANDARD: RTCA DO-160G
CONDITIONS SECTION
DESCRIPTION OF TEST
Temperature and Altitude
Low
Temperature
High
Temperature
In-Flight Loss of Cooling
Decompression
Overpressure
4
4.5.1
4.5.2
4.5.5
4.6.2
4.6.3
Category F3(Y)
Operating Low Temp = -55C
Operating High Temp = +70C
Category Y = 300 minutes, +40C, 75%
Altitude = +55,000 ft.
-15,000 ft.
Temperature Variation
5
Category S2
Humidity 6
Category
B
Operational Shock and
Crash Safety
7 Category
B
Vibration
8
Category R; Curve C, C1 [(RCC1)]
Category U; Curve G
Explosion 9 Category
X
Waterproofness 10
Category
X
Fluids 11
Category
X
Sand and Dust
12
Category X
Fungus 13
Category
X
Salt Spray
14
Category X
Magnetic Effect
15
Category Z
Power Input
16
Category Z
Voltage Spike
17
Category A
Audio Frequency Conducted
Susceptibility
18 Category
R
Induced Signal Susceptibility
19
Category (ZC)
Radio Frequency Susceptibility
20
Category (RR)
Emission of Radio Freq Energy
21
Category M
Lightning Induced Transient
Susceptibility
22
Category A3 (pin injection)
Category G3L3 (cable bundle)
[A3G3L3]
Lightning Direct Effects
23
Category X
Icing 24
Category
X
ESD 25
Category
A
Flammability 26 Category
X