background image

 

16

 

• 

Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts 
of the building. This may be achieved by using insulated high voltage cable. 

• 

Connecting leads that are run underground shall be run in conduit of insulating material or else insulated 
high voltage cable shall be used. Care must be taken to avoid damage to the connecting leads due to the 
effects of vehicle wheels sinking into the ground. 

• 

Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication 
cables or data cables. 

• 

Connecting leads and electric security fence wires shall not cross above overhead power or communication 
lines. 

• 

Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be 
avoided it shall be made underneath the power line and as nearly as possible at right angles to it. 

• 

If connecting leads and electric security fence wires are installed near an overhead power line, the 
clearances shall not be less than those shown in the table below. 

Minimum clearances from power lines for electric security fences 

Power line voltage (V) 

Clearance (m) 

1 000 

>1 000  and  

33 000 

>33 000 



• 

If connecting leads and electric security fence wires are installed near an overhead power line, their height 
above the ground shall not exceed 3 m 

• 

This height applies to either side of the orthogonal projection of the outermost conductors of the power 
line on the ground surface, for a distance of: 

-  2 m for power lines operating at a nominal voltage not exceeding 1 000 V 
-  15 m for power lines operating at a nominal voltage exceeding 1 000 V. 

• 

A spacing of 2.5 m shall be maintained between uninsulated electric security fence conductors or 
uninsulated connecting leads supplied from separate energizers. This spacing may be less where conductors 
or connecting leads are covered by insulating sleeving, or consist of insulated cables rated to at least 10 kV. 

• 

This requirement need not apply where the separately energized conductors are separated by a physical 
barrier that does not have any openings greater than 50 mm. 

• 

A vertical separation of not less than 2 m shall be maintained between pulsed conductors fed from separate 
energizers. 

• 

Electric security fences shall be identified by prominently placed warning signs. 

• 

The warning signs shall be legible from the secure area and the public access area. 

• 

Each side of the electric security fence shall have at least one warning sign. 

• 

Warning signs shall be placed: 
-  at each gate; 
-  at each access point; 

-  at intervals not exceeding 10 m;  
-  adjacent to each sign relating to chemical hazards for the information of the emergency services. 

• 

Any part of an electric security fence that is installed along a public road or pathway shall be identified at 
frequent intervals by warning signs securely fastened to the fence posts or firmly clamped to the fence 
wires. 

• 

The size of the warning sign shall be at least 100 mm × 200 mm. 

• 

The background colour of both sides of the warning sign shall be yellow. The inscription on the sign shall 

be black and shall be either: 
-  the symbol of Figure 1, or 
-  the substance of “CAUTION: Electric security fence”. 

• 

The inscription shall be indelible, inscribed on both sides of the warning sign and have a height of at least 
25 mm. 

Содержание Electric Fence Security System

Страница 1: ...e trademarks of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical pho...

Страница 2: ...t distinguishes sudden fence voltage changes from slow changes caused by environmental degradation Provision for up to four Keypads and or Keyswitches altogether Full gate access control using low vol...

Страница 3: ...ator lamps these allow the unit to be installed on its own without a Keypad or Keyswitch It has the same full range of features and customisable settings as provided on the Premium but these are set b...

Страница 4: ...factory default OPIN is 5555 The Keypad will give a short beep to confirm each key press a long high pitched beep after each successful command sequence and a long low pitched beep after an invalid c...

Страница 5: ...right until a fast beeping is heard 3 Return the key back to the upright position and remove Disarming using the Keypad To disarm the system enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY...

Страница 6: ...tering Monitor mode using the Keypad To set Monitor mode enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 Monitor using User PIN U P I N or Owner PIN O P I N Note that in Monito...

Страница 7: ...KEY 2 KEY 3 KEY 4 KEY 5 Return to Standby using User PIN U P I N or Owner PIN O P I N The system will disarm the Armed lamp will turn off and the Pulse lamp will stop flashing Tip You may instantly ac...

Страница 8: ...Each subsequent activation of the alarm will normally cause the siren to be re triggered The siren can be silenced immediately by the user without deactivating the electric fence security system This...

Страница 9: ...to your assistance The siren will not time out and will continue until you exit Panic mode Note A panic alarm cannot be raised using the Keyswitch Exiting Panic mode Exiting Panic mode using the Keys...

Страница 10: ...ce of your installer On Mains power on and battery good Off Normal operation if armed system is secure Flashing Fence alarm condition present On Fence currently secure but the fence alarm has previous...

Страница 11: ...ch where fitted If the gate has been left open after a short period has elapsed half of the exit delay time the chime will sound once every 10 seconds as a warning Tamper alarm If someone tampers with...

Страница 12: ...uired to change these PIN numbers whereas the UPIN cannot do this even for the UPIN itself Setting the UPIN To set the UPIN enter the current OPIN followed by the command and then key in the new UPIN...

Страница 13: ...lashing fast Additionally the beeper will sound in the Keyswitch and Keypad Ask your service agent for assistance If the supply cord is damaged it must only be replaced by your service agent in order...

Страница 14: ...have it checked and repaired promptly by your service agent to ensure system integrity The Power Pack supply cord cannot be replaced If the cord is damaged the whole Power Pack should be replaced Ens...

Страница 15: ...d their ancillary equipment shall be installed operated and maintained in a manner that minimizes danger to persons and reduces the risk of persons receiving an electric shock unless they attempt to p...

Страница 16: ...ge not exceeding 1 000 V 15 m for power lines operating at a nominal voltage exceeding 1 000 V A spacing of 2 5 m shall be maintained between uninsulated electric security fence conductors or uninsula...

Страница 17: ...suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Figure 1 Symbol for warning sign Warranty This product is warranted against faulty material and workmanship for a p...

Отзывы: