10
Months
(Northern hemisphere)
Plate meter equations
(Dairy pastures)
Winter (October/March)
Plate meter reading x 140 + 500 (factory default)
April
Plate meter reading x 115 + 850
May
Plate meter reading x 120 + 1000
June
Plate meter reading x 140 + 1200
July
Plate meter reading x 140 + 1200
August
Plate meter reading x 185 + 1200
September
Plate meter reading x 170 + 1100
Some equations may change without notice and are influenced by
seasonal differences. If you are unsure of the current equation contact
Dairy NZ or your local consultant.
To enter your own cover equation or one that may have been recommended by a
third party, such as your consultant, Dairy NZ or Beef + Lamb New Zealand, please
do the following:
1
While the plate meter is switched on, hold down the “Formula” button. The
display looks like this: “F--d”. Press the formula button again briefly - then
change the “d” (default) to “c” (custom). Now press “Reset” briefly and the
display will look like this: “0---” This is the first of two numbers you will enter.
The first number is the equation “add” number and the second the “multiply
number. For example, in equation 2 above, the first number (115) is the
“multiply” number and the second (850) is the “add” number.