![TRU Components KMP001-1 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/tru-components/kmp001-1/kmp001-1_operating-instructions_1173744002.webp)
Operating instructions
IR Motion Detector KMP001-1
Item no. 1572220
Intended use
This IR motion detector detects heat radiation from moving bodies (e.g. people and animals) and emits an
electrical output signal. The sensor and the control unit are connected via cable, allowing the control unit to
be installed out of sight behind a faceplate.
It is intended for indoor use only. Do not use it outdoors. Contact with moisture, e.g. in bathrooms, must be
avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product
for purposes other than those described above, the product may be damaged. In addition, improper use can
cause hazards such as short circuiting, fire, electric shock etc. Read the instructions carefully and keep them.
Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and
product names are trademarks of their respective owners. All rights reserved.
Delivery content
• IR Motion Detector
• Operating instructions
Latest operating instructions
Download the latest operating instructions via the link
www.conrad.com/downloads or scan the QR code
shown. Follow the instructions on the website.
Explanation of symbols
The lightning symbol inside a triangle is used when there is a potential risk of personal injury,
such as electric shock.
An exclamation mark in a triangle indicates important instructions in this operating manual that
absolutely have to be observed.
The arrow symbol indicates specific tips and advice on operation.
Safety instructions
Read the operating instructions carefully and especially observe the safety information.
If you do not follow the safety instructions and information on proper handling in this
manual, we assume no liability for any resulting personal injury or damage to property.
Such cases will invalidate the warranty/guarantee.
• The device is not a toy. Keep it out of the reach of children and pets.
•
Do not leave packaging material lying around carelessly. This may become dangerous playing
material for children.
•
Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity,
moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
•
If it is no longer possible to operate the product safely, take it out of operation and protect it
from any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
-
is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
-
has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage
the product.
• Also observe the safety and operating instructions of any other devices which are connected
to the product.
• Consult an expert when in doubt about operation, safety or connection of the device.
•
Maintenance, modifications and repairs are to be performed exclusively by an expert or at a
qualified shop.
• If you have questions which remain unanswered by these operating instructions, contact our
technical support service or other technical personnel.
Detection angle and range
2.5 m
2.0 m
approx. 2.0 m
approx. 3.6 m
ENG
approx. 2 m
approx. 3.6 m
2.0 m
2.5 m
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in
part, is prohibited. This publication represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.
*1572220_V1_0318_02_mxs_m_en
On-time and twilight threshold
On-time selection switch
T icon:
On-time is set to 3 seconds
Clock icon:
On-time is set to 12 minutes
Twilight threshold selection switch
Sun icon:
The sensor functions at 2000 lux max.
Moon icon:
The sensor will only function below 3 lux
Dimensions and installation
Note when installing that the thread is flattened on two sides, to ensure that the IR lens cannot turn.
Mounting
hole
5 mm
13 mm
6 mm max.
ø 9.6 mm
ø 15 mm
90 mm
View: back / thread sides are flattened
View: back / thread sides are flattened
Mounting hole
Ø 15 mm
Ø 9.6 mm
90 mm
5 mm
13 mm
6 mm max.
46 mm
57.5 mm
63 mm
brown
red
blue
57.5 mm
63 mm
46 mm
blue
red
brown
Care and cleaning
• Disconnect the product from the power supply before cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause
damage to the housing and malfunctioning.
•
Clean the product with a dry, fiber-free cloth.
• Do not immerse the product in water.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household waste. At
the end of its service life, dispose of the product according to the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
Technical data
Operating voltage ................................. 220 – 240 V/AC, 50 Hz
Switching capacity ................................ 600 W (resistive load), 300 W (inductive load)
On-time ................................................. 3 sec – 12 min
Sensitivity ............................................. 3 – 2000 lux
Detection angle ..................................... 150° (vertically), 360° (horizontally)
Range ................................................... max. 3.6 m
Operating temperature ......................... -10 to +40 °C
Storage temperature ............................. -10 to +50 °C
Operating humidity ............................... up to 93 % relative humidity