Important notes

Information on the installation manual

This manual enables operating or service personnel
to correctly install the product described below and
to use it safely and efficiently.

It is essential that these individuals read and fully
understand this manual before starting any work.
The basic prerequisite for safe working is to comply
with the safety notes and all instructions in this
manual.

The local regulations for health and safety at work
and general safety regulations also apply.

Correct use

The type TFP pharmaceutical clean room terminal
filter for ceiling installation is used as a final filter for
the separation of suspended particles and for air
distribution. Sample applications include medicine,
biology, pharmaceuticals, and sensitive technical
areas.

The TFP can be used in the supply air and extract
air of ventilation and air conditioning systems. They
are suitable for the fitting of Mini Pleat filter panels
for the separation of suspended particles, to ensure
critical air cleanliness and meet demanding hygiene
requirements.

It is important that you comply with any national
hygiene regulations when you install, commission
or use the pharmaceutical clean room terminal filter.

Incorrect use

 WARNING!

Danger due to incorrect use!

Incorrect use of the unit can lead to dangerous
situations.

Never use the unit:

in areas with potentially explosive atmos-
pheres

in humid rooms

in rooms with aggressive or dust-laden air

Limitation of liability

The information in this manual has been compiled
with reference to the applicable standards and
guidelines, the state of the art, and our expertise
and experience of many years.

The manufacturer does not accept any liability for
damages resulting from:

Non-compliance with this manual

Incorrect use

Operation or handling by untrained individuals

Unauthorised modifications

Technical changes

Use of non-approved replacement parts

The actual scope of delivery may differ from the
information in this manual for bespoke construc-
tions, additional order options or as a result of
recent technical changes.

The obligations agreed in the order, the general
terms and conditions, the manufacturer's terms of
delivery, and the legal regulations in effect at the
time the contract is signed shall apply.

We reserve the right to make technical changes.

Defects liability

For details regarding defects liability please refer to
Section VI, Warranty Claims, of the Delivery and
Payment Terms of TROX GmbH.

The Delivery and Payment Terms of TROX GmbH
are available at 

www.troxtechnik.com

.

Qualified staff

HVAC technician

HVAC technicians are individuals who have suffi-
cient professional or technical training in the field
they are working in to enable them to carry out their
assigned duties at the level of responsibility allo-
cated to them and in compliance with the relevant
guidelines, safety regulations and instructions.
HVAC technicians are individuals who have in-
depth knowledge and skills related to HVAC sys-
tems; they are also responsible for the professional
completion of the work under consideration.

Important notes

 

TFP Pharmaceutical clean room terminal filters

2

Содержание TFP-TC-S

Страница 1: ...Springs x2 Turn clip x4 Filter Diffuser face Installation and mainte nance manual GB en TFP Pharmaceutical clean room terminal filters TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Ger many Ger...

Страница 2: ...ility The information in this manual has been compiled with reference to the applicable standards and guidelines the state of the art and our expertise and experience of many years The manufacturer do...

Страница 3: ...ar checks and smaller adjustments Personal protective equipment Personal protective equipment must be worn for any work in order to reduce health or safety haz ards to the minimum The appropriate prot...

Страница 4: ...ondensation Assembly General information Personnel HVAC technician Protective equipment Industrial safety helmet Protective gloves Safety shoes DANGER Danger of death from the fall of suspended loads...

Страница 5: ...eaded rod without changing the position of the TFP casing and secure it with a locknut Fixing to the suspended ceiling Fig 3 Fixing to the load bearing suspended ceiling C rail Support angle section L...

Страница 6: ...ation proce dure protect all openings from the ingress of dust If necessary clean the ducts before you com mission the ventilation system Commissioning General information Before you start commissioni...

Страница 7: ...sing until it clicks into place at the springs Fig 4 2 4 Tighten the turn clips x4 crosswise in a clockwise direction as far as they will go For this use the key provided or a commercially available A...

Страница 8: ...particle count has been exceeded The maximum filter usage time has been reached 8 years to VDI 3803 part 4 You may replace a filter even before the defined final differential pressure has been reache...

Страница 9: ...iffuser face Differential pressure measurement The initial differential pressure for TROX filters is given on the label on the filter frame There are two ways to measure the differential pressure Perm...

Страница 10: ...espiratory protection Protective gloves Before you start changing filters switch off the air conditioning system or close the shut off damper for the corresponding air stream if any 1 Remove the diffu...

Страница 11: ...d using only original TROX filters Original TROX filters carry a sticker on the frame with both the use before date and information on how to order replacements To avoid downtime of the ventilation an...

Страница 12: ...TFP Pharmaceutical clean room terminal filters 12...

Отзывы: