Product overview

Fig. 1: Schematic illustration, e. g. TFP-TC-S

Casing

Differential pressure measuring point (x2)

Suspension (x4)

Spigot with lip seal

Internal measuring tube

Seal blade

Magnet (x2)

Springs (x2)

Turn clip

 (x4)

Filter

Diffuser face

Installation and mainte-
nance manual

GB/en

TFP

Pharmaceutical clean room terminal
filters

TROX GmbH

Heinrich-Trox-Platz
47504 Neukirchen-Vluyn, Ger-
many
Germany
Phone: +49 (0) 2845 2020
Fax: +49 (0) 2845 202265
E-mail: [email protected]
Internet: http://www.trox-
technik.com

A00000071507, 12/2018, 

©

 2018 TROX GmbH

 

TFP Pharmaceutical clean room terminal filters

1

Содержание TFP-TC-S

Страница 1: ...Springs x2 Turn clip x4 Filter Diffuser face Installation and mainte nance manual GB en TFP Pharmaceutical clean room terminal filters TROX GmbH Heinrich Trox Platz 47504 Neukirchen Vluyn Ger many Ger...

Страница 2: ...ility The information in this manual has been compiled with reference to the applicable standards and guidelines the state of the art and our expertise and experience of many years The manufacturer do...

Страница 3: ...ar checks and smaller adjustments Personal protective equipment Personal protective equipment must be worn for any work in order to reduce health or safety haz ards to the minimum The appropriate prot...

Страница 4: ...ondensation Assembly General information Personnel HVAC technician Protective equipment Industrial safety helmet Protective gloves Safety shoes DANGER Danger of death from the fall of suspended loads...

Страница 5: ...eaded rod without changing the position of the TFP casing and secure it with a locknut Fixing to the suspended ceiling Fig 3 Fixing to the load bearing suspended ceiling C rail Support angle section L...

Страница 6: ...ation proce dure protect all openings from the ingress of dust If necessary clean the ducts before you com mission the ventilation system Commissioning General information Before you start commissioni...

Страница 7: ...sing until it clicks into place at the springs Fig 4 2 4 Tighten the turn clips x4 crosswise in a clockwise direction as far as they will go For this use the key provided or a commercially available A...

Страница 8: ...particle count has been exceeded The maximum filter usage time has been reached 8 years to VDI 3803 part 4 You may replace a filter even before the defined final differential pressure has been reache...

Страница 9: ...iffuser face Differential pressure measurement The initial differential pressure for TROX filters is given on the label on the filter frame There are two ways to measure the differential pressure Perm...

Страница 10: ...espiratory protection Protective gloves Before you start changing filters switch off the air conditioning system or close the shut off damper for the corresponding air stream if any 1 Remove the diffu...

Страница 11: ...d using only original TROX filters Original TROX filters carry a sticker on the frame with both the use before date and information on how to order replacements To avoid downtime of the ventilation an...

Страница 12: ...TFP Pharmaceutical clean room terminal filters 12...