
A.5
Volume flow control for supply air and extract air
including room pressure control
T
R
O
X
U
N
IVE
R
S
A
L
:
P
h
o
n
e
:
+
4
9
-2
8
4
5
-2
0
2
-
P
M
/
T
R
O
X
U
N
IV
E
R
S
A
L
R
E
G
L
E
R
D
a
tu
m
1
3
.1
0
.1
7
R
E
V
A
S
e
it
e
9
v
o
n
9
T
R
O
X
U
N
IV
E
R
S
A
L
R
e
g
le
r
T
C
U
3
Z
u
lu
ft
R
a
u
m
z
u
lu
ft
re
g
le
r
T
U
*
-
R
S
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
K
L
-K
O
M
M
U
N
IK
A
T
IO
N
C
O
M
M
-1
X
6
C
O
M
M
-2
X
7
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
A
C
T
U
A
T
O
R
A
O
X
4
rt=
24
V
ws=
AO
4
sw=
GN
D
St
e
ll
a
n
tr
ie
b
N
=
S
ta
n
d
a
rd
1
5
0
s
N
F
=
F
e
d
e
rr
ü
c
kl
a
u
f
1
5
0
s
S
=
s
c
h
n
e
ll
la
u
fe
n
d
4
s
B
e
d
ie
n
e
in
h
e
it
B
E
-L
C
D
-0
1
T
E
R
M
IN
A
L
1
+
2
X
2
X
3
AO1
GND
Lokaler Ist-
Volumenstrom
AO2
GND
Soll-Volumenstrom
Folgeregler
C
NC
NO
D
O
1
L
o
ka
le
r
A
la
rm
A
n
a
lo
g
e
in
g
a
n
g
V
o
rg
a
b
e
S
o
ll
V
o
lu
m
e
n
st
ro
m
R
a
u
m
AI2
GN
D
24
V A
C
GN
D
P
o
w
e
r
2
4
V
A
C
AO3
GND
Klappenstellung
Regler
R
a
u
m
-M
a
n
a
g
e
m
e
n
t-
F
u
n
kt
io
n
R
M
F
T
R
O
X
U
N
IV
E
R
S
A
L
R
e
g
le
r
T
C
U
3
A
b
lu
ft
R
a
u
m
z
u
lu
ft
re
g
le
r
T
U
*
-
R
E
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
K
L
-K
O
M
M
U
N
IK
A
T
IO
N
C
O
M
M
-1
X
6
C
O
M
M
-2
X
7
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
A
C
T
U
A
T
O
R
A
O
X
4
rt=
24
V
ws=
AO
4
sw=
GN
D
St
e
ll
a
n
tr
ie
b
N
=
S
t
a
n
d
a
rd
1
5
0
s
N
F
=
F
e
d
e
rr
ü
c
k
la
u
f
1
5
0
s
S
=
s
c
h
n
e
ll
la
u
fe
n
d
4
s
AO1
GND
Lokaler Ist-
Volumenstrom
C
NC
NO
D
O
1
L
o
ka
le
r
A
la
rm
24
V A
C
GN
D
P
o
w
e
r
2
4
V
A
C
AO3
GND
Klappenstellung
Regler
K
L
KL
-T
e
rm
KL
-T
e
r
m
R
a
u
m
b
e
tr
ie
b
s
a
rt
R
e
d
u
zi
e
rt
(
V
m
in
)
P
o
te
n
ti
a
lf
re
ie
r
K
o
n
ta
kt
g
e
sch
lo
sse
n
=
r
e
d
u
zi
e
rt
(S
ch
a
lt
e
r
b
a
u
se
it
s)
DI2
GN
D
R
a
u
m
b
e
tr
ie
b
s
a
rt
E
rh
ö
h
t
(V
m
a
x
)
P
o
te
n
ti
a
lf
re
ie
r
K
o
n
ta
kt
g
e
sch
lo
sse
n
=
e
rh
ö
h
t
(S
ch
a
lt
e
r
b
a
u
se
it
s)
DI3
GN
D
R
a
u
m
b
e
tr
ie
b
s
a
rt
A
b
s
p
e
rr
u
n
g
(
Z
u
)
P
o
te
n
ti
a
lf
re
ie
r
K
o
n
ta
kt
g
e
sch
lo
sse
n
=
zu
(S
ch
a
lt
e
r
b
a
u
se
it
s)
DI4
GN
D
Volumenstromregelung
Zu-
&
Abluft
sowie
Raumdruck
Master
-
S
l
ave
T
R
O
X
U
N
IV
E
R
S
A
L
R
e
g
le
r
T
C
U
3
D
ru
c
k
A
b
lu
ft
R
a
u
m
d
ru
c
k
re
g
le
r
A
u
lu
ft
T
U
*
-
P
R
E
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
K
L
-K
O
M
M
U
N
IK
A
T
IO
N
C
O
M
M
-1
X
6
C
O
M
M
-2
X
7
A
n
sch
lü
sse
G
e
h
ä
u
se
a
u
ß
e
n
se
it
e
A
C
T
U
A
T
O
R
A
O
X
4
rt=
24
V
ws=
AO
4
sw=
GN
D
St
e
ll
a
n
tr
ie
b
N
=
S
ta
n
d
a
r
d
1
5
0
s
N
F
=
F
e
d
e
r
r
ü
c
kl
a
u
f
1
5
0
s
S
=
s
c
h
n
e
ll
la
u
fe
n
d
4
s
AO2
GND
Istdruck Raum
C
NC
NO
D
O
1
L
o
ka
le
r
A
la
rm
24
V A
C
GN
D
P
o
w
e
r
2
4
V
A
C
A
n
a
lo
g
e
in
g
a
n
g
V
o
rg
a
b
e
S
o
lld
ru
ck
R
a
u
m
0
-1
0
o
.
2
-1
0
V
AI4
GN
D
AO3
GND
Klappenstellung
Regler
Ist
we
rt
0-1
0 V
GN
D
GN
D
24
V
24
V
A
C
GN
D
AI
5
-
+
Dr
u
c
k
fü
h
le
r
b
a
u
s
e
it
s
.
D
o
k
u
m
e
n
ta
ti
o
n
d
e
s
F
ü
h
le
rs
b
e
a
c
h
te
n
!
K
L
Control components for VAV terminal units TROX UNIVERSAL
35