EN
15
wet and dry vacuum cleaner VC 1200W
The device is running, but no detergent or an insufficient
amount of detergent is sprayed:
•
The detergent tank may be empty. Check the fill level and
refill new detergent, if necessary.
•
The individual parts of the detergent pipe may not be
properly connected to each other. Check whether the suction
hose of the tank is connected to the suction side of the
detergent pump (
23
), the detergent pipe (
2
) is inserted into
the fitting (
22
), and whether the individual elements between
the hose, suction pipe and nozzle are firmly connected.
•
The detergent pipe may be blocked. Check whether any of the
elements of the detergent pipe are dirty. Remove any dirt.
•
The detergent may be too viscous and cannot be drawn in
properly. Dilute viscous detergent with water.
•
The detergent pump may be defective. If the detergent
pump is defective, have it replaced by a specialist
electrical company.
The spray jet is unsteady:
•
The spray nozzle may be blocked. Check the spray nozzle
for dirt. Remove any dirt.
Foam or waste water is escaping from the air outlet
opening (3) during operation
•
The filter may not be inserted correctly. Check the filter
and insert it correctly, if necessary.
•
The filter is heavily contaminated. Check the filter for dirt
and clean it, if necessary, or change it as described in the
Maintenance chapter.
•
There is too much waste water or foam in the collection
container. Empty the collection container and clean it as
described in the Maintenance chapter. Do not use any
strongly foaming detergent.
The device is emitting loud noises
•
The collection container has reached the maximum water
capacity. The water valve starts working and causes the
noises. Empty and clean the collection container.
The detergent pump is working too noisily:
•
The detergent tank may be empty. Check the fill level and
refill new detergent, if necessary.
•
The detergent pump may be defective. If the detergent
pump is defective, have it replaced by a specialist
electrical company.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.
Cleaning
The device should be checked for dirt at regular intervals and
cleaned as required.
Warning of electrical voltage
There is a risk of short circuits if the electrical
equipment in the device interior comes into contact
with water!
Do not immerse the device and the accessories in
water. Ensure that no liquids enter the device interior.
•
Clean the device with a soft, damp and lint-free cloth.
Make sure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.
•
Dry the device with a soft, lint-free cloth.
•
Keep the ventilation openings free from dust deposits to
prevent overheating of the motor.