Trotec VC 1200W Скачать руководство пользователя страница 15

EN

15

wet and dry vacuum cleaner VC 1200W

The device is running, but no detergent or an insufficient
amount of detergent is sprayed:

The detergent tank may be empty. Check the fill level and
refill new detergent, if necessary.

The individual parts of the detergent pipe may not be
properly connected to each other. Check whether the suction
hose of the tank is connected to the suction side of the
detergent pump (

23

), the detergent pipe (

2

) is inserted into

the fitting (

22

), and whether the individual elements between

the hose, suction pipe and nozzle are firmly connected.

The detergent pipe may be blocked. Check whether any of the
elements of the detergent pipe are dirty. Remove any dirt.

The detergent may be too viscous and cannot be drawn in
properly. Dilute viscous detergent with water.

The detergent pump may be defective. If the detergent
pump is defective, have it replaced by a specialist
electrical company.

The spray jet is unsteady:

The spray nozzle may be blocked. Check the spray nozzle
for dirt. Remove any dirt.

Foam or waste water is escaping from the air outlet
opening (3) during operation

The filter may not be inserted correctly. Check the filter
and insert it correctly, if necessary.

The filter is heavily contaminated. Check the filter for dirt
and clean it, if necessary, or change it as described in the
Maintenance chapter.

There is too much waste water or foam in the collection
container. Empty the collection container and clean it as
described in the Maintenance chapter. Do not use any
strongly foaming detergent.

The device is emitting loud noises

The collection container has reached the maximum water
capacity. The water valve starts working and causes the
noises. Empty and clean the collection container.

The detergent pump is working too noisily:

The detergent tank may be empty. Check the fill level and
refill new detergent, if necessary.

The detergent pump may be defective. If the detergent
pump is defective, have it replaced by a specialist
electrical company.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.

Cleaning

The device should be checked for dirt at regular intervals and
cleaned as required.

Warning of electrical voltage

There is a risk of short circuits if the electrical
equipment in the device interior comes into contact
with water!
Do not immerse the device and the accessories in
water. Ensure that no liquids enter the device interior.

Clean the device with a soft, damp and lint-free cloth.
Make sure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.

Dry the device with a soft, lint-free cloth.

Keep the ventilation openings free from dust deposits to
prevent overheating of the motor.

Содержание VC 1200W

Страница 1: ...TRT BA VC1200W TC220628TTRT01 001 EN VC 1200W EN OPERATING MANUAL WET AND DRY VACUUM CLEANER...

Страница 2: ...the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shoc...

Страница 3: ...quid inside the device The liquid could enter the engine and damage it Switch off the device immediately if foam or liquid escape from it Do not use the device as a pump Do not fill the detergent tank...

Страница 4: ...ower cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Device description The device VC 1200W is suited for vacuuming dry or wet surfaces dr...

Страница 5: ...pipe 3 Air outlet opening 4 Handle 5 Lock 6 Air intake opening 7 Collection container 8 Swivel castors 9 Spray floor nozzle 10 On off switch 11 Spray nozzle button 12 Suction pipe 13 Wheels 14 Cleani...

Страница 6: ...gth 1 8 m Weight 7 5 kg Dimensions length x width x height 36 x 33 x 43 5 cm Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information r...

Страница 7: ...e opening on the bottom of the device 2 Fasten the larger wheels at the rear 13 with two screws each The wheels 13 will click into place 13 8 Utilising the air intake opening and air outlet opening Yo...

Страница 8: ...ng button 24 on the suction pipe 3 Insert the end of the detergent pipe 2 into the fitting and let go of the locking button 24 II I II III 1 12 2 IV 24 4 If required attach the second suction pipe 12...

Страница 9: ...he connecting piece of the detergent pipe 2 onto the fitting of the suction pipe To do so align the connecting piece so that the lugs on the fitting match the recesses on the connecting piece 5 Turn t...

Страница 10: ...ides of the device 2 Remove the device head 27 from the collection container 7 27 5 5 I II 7 3 Loosen the filter housing 28 by turning it in clockwise direction Remove the filter housing from the devi...

Страница 11: ...ection container 7 6 Close the locks 5 on both sides of the device Proceed as follows to remove the dust bag 18 1 Open the locks 5 on both sides of the device 2 Remove the device head 27 from the coll...

Страница 12: ...e direction II 23 I II Operation Tips and notes on handling the vacuum cleaner Before vacuuming refer to the respective manufacturer to obtain care instructions for your flooring or floors Never use t...

Страница 13: ...Changing the nozzles chapter 2 Switch the device to position II 3 At the start keep the spray button on the hose handle 11 pressed until detergent sprays out of the nozzle The device is ready for cle...

Страница 14: ...rs and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list Troubleshooting task...

Страница 15: ...ollection container has reached the maximum water capacity The water valve starts working and causes the noises Empty and clean the collection container The detergent pump is working too noisily The d...

Страница 16: ...ilter must be replaced if required Note The lifetime of the HEPA filter and foam filter depends on the ambient conditions and the application period of the device The HEPA filter and foam filter must...

Страница 17: ...Empty the detergent tank 14 4 Rinse the detergent tank 14 with water 5 Reinsert the detergent tank 14 into the rear of the device 14 6 Insert the end of the detergent pipe 2 into the rear holding fixt...

Страница 18: ...points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other retu...

Страница 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: