360° turbo fan TVE 100
No.
Designation
Meaning
8
Rotary switch
Setting the fan stage
setting the number of hours of the
timer
9
Illumination
button
Switching illumination on or off
10
Swing
LED
Is illuminated when the vertical swing
function is activated
11
Mode
button
Selecting the operating mode:
Normal operation
Natural wind
Night mode
12
On/off
button
Switching the device on or off
13
Oscillation
button Switching horizontal oscillation on or
off
14
Oscillation
LEDs
The corresponding LED is illuminated
when oscillation has been selected
for the angles 30°, 90°, 180°
or 360°.
15
Swing
button
Switching the vertical swing function
on or off
16
On/off
LED
Illuminated when the device is
switched on
17
Mode
LEDs
Indicate the selected operating mode:
=
natural wind
=
night mode
18
Timer
button
Timer function: automatic switch-on
and switch-off
19
Display
Indication of the fan stage and the
LED
Indication of the number of hours of
the activated timer (1 h to 12 h) and
the LED
h
20
Up
button
Increasing the fan speed
Increasing the number of hours of the
activated timer
21
Down
button
Decreasing the fan speed
Decreasing the number of hours of
the activated timer
Switching the device on
Once you have completely installed the device as described in
the chapter Assembly and start-up, you can switch it on.
1. Press the
On/off
button (
12
).
ð
The
On/off
LED (
16
) is illuminated.
ð
An acoustic signal is emitted and the device starts up in
Normal operation
mode.
Info
When the device is switched on, the display is
automatically dimmed after 1 minute.
Setting the operating mode
The device has the following operating modes:
•
Normal operation
•
Natural wind
•
Night mode
Normal operation
Note
When
normal operation
is activated, there is no specific
LED to indicate the operating mode.
In
normal operation
mode the fan keeps running at the desired
fan stage. The fan stage can be set from 1 to 32 in this
operating mode and is indicated on the display (
19
).
Please proceed as follows to set the fan stage in
normal
operation
mode:
1. Press the
Mode
button (
11
) until neither the
LED nor
the
LED (
17
) is illuminated.
ð
The device runs in
normal operation
mode.
ð
The
LED is illuminated on the display (
19
).
2. Turn the rotary switch (
8
) clockwise to increase the fan
stage.
Turn the rotary switch (
8
) counter-clockwise to reduce the
fan stage.
ð
The selected fan stage in shown on the display (