Operating manual – dehumidifier TTK 95 E

Information about the device

Device description

The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to 
approx. 30 %.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.

Device depiction

1

2

3

4

5

6

7

8

9

No.

Designation

1

Control panel

2

Condensation tank with filling level indicator

3

Air inlet with air filter

4

Condensation drain hose connection

5

Power cable winder

6

Air filter

7

Wheels

8

Transport handle

9

Air outlet

Содержание TTK 95 E

Страница 1: ...TRT BA TTK95E TC 001 EN TTK 95 E EN OPERATING MANUAL DEHUMIDIFIER ...

Страница 2: ...l helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed The current version of the operating manual can be found at TTK 95 E http hub trotec com id 39477 Legal notice This release replaces all previous versions No part of this publication may be reproduced without written permission from Trote...

Страница 3: ...t operate it when wet Do not use the device with wet or damp hands Do not expose the device to directly squirting water Never insert any objects or limbs into the device Do not cover or transport the device during operation Do not sit on the device This appliance is not a toy Keep away from children and animals Do not leave the device unattended during operation Check accessories and connection pa...

Страница 4: ...he Safety chapter Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company Warning of electrical voltage Before any work on the device remove the mains plug from the...

Страница 5: ...below It is fitted with a float to measure the filling level The device has a control panel for operating and controlling the functions Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly the condensation tank indicator light see chapter Operating elements on the control panel is illuminated The device switches off The cond...

Страница 6: ...If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining condensate from the device and the condensation drain hose see chapter Maintenance Empty and clean the condensation tank prior to storage When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is ...

Страница 7: ...r other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the respective regulations Inserting the air filter Note Do not operate the device without an inserted air filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and...

Страница 8: ...ive room humidity Indicates the desired relative room humidity during setting 14 Defrost indication Is displayed when automatic defrosting is in progress 15 Fan speed indication Indication of the fan speed low high laundry drying function 16 Swing function indication Is displayed when the swing function is activated 17 Ventilation button Setting the fan speed low high laundry drying function 18 Po...

Страница 9: ...tween 1 and 24 and can be adjusted in increments of 1 h Note Do not leave the operating device unattended in a freely accessible room with an activated timer Automatic switch on 1 Switch off the device 2 Press the timer button 19 ð The number of hours flashes on the timer indication 21 3 Press the increase value 11 or decrease value button 23 to set the desired number of hours 4 Wait for approx 5 ...

Страница 10: ...ce is switched off 1 Remove the sealing cap from the hose connection 2 Remove the rubber plug 3 Push one end of the hose onto the hose connection 4 Guide the other hose end to a suitable drain or sufficiently dimensioned collection container Please observe that the hose must not be kinked Remove the hose if you want to collect the condensate in the condensation tank again Allow the hose to dry pri...

Страница 11: ...sation tank if need be Clean the device according to the Maintenance chapter Store the device according to the Storage chapter Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list The device does not start Check the power connection Check the power cable and mains plug...

Страница 12: ... has tripped Disconnect the device from the mains and let it cool down for approx 10 minutes before reconnecting it The device might carry out an automatic defrost During automatic defrost the device does not dehumidify The device gets very warm is loud or loses power Check the air inlets and air filter for dirt Remove external dirt From the outside check the device for dirt see chapter Maintenanc...

Страница 13: ...ent screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty condensation tank and drain hose Check the air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean or...

Страница 14: ... illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by speci...

Страница 15: ... detergent 4 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly Also make sure that the condensation tank is inserted correctly otherwise the device cannot be switched back on Activities required after maintenance If you want to continue using the device Leave th...

Страница 16: ... PE 230 V 50 Hz Power input 0 6 kW Nominal current 2 6 A Refrigerant R134a Amount of refrigerant 215 g Condensation tank capacity 5 3 l Sound pressure level 1 m distance 47 dB A Dimensions length x width x height 240 x 368 x 560 mm Minimum distance to walls and other objects A top B rear C side D front 20 cm 20 cm 20 cm 20 cm Weight 16 kg Wiring diagram SCHEMATICWIRINGDIAGRAM N 1 2 5 1 52 1 2035 6...

Страница 17: ...Operating manual dehumidifier TTK 95 E Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual 47 ...

Страница 18: ... NHAF 29 PC BOARD 46 TOP COVER 13 BLOWER WHEEL 30 FIX METAL 47 HANDLE 14 FAN TANK 31 SENSOR FOR EVAPORATOR ASS Y 9 48 FIX TUBE 15 DISCHARGE GRILLE 32 POWER SUPPLY CORD COMPLETET ASS Y 49 Y TUBE 16 MICRO SWITCH 33 DECORATIVE PLARES 50 OVER LOAD PROTECTOR B90 135D 241A 17 FIX TUBE 34 DECORATIVE PLARES Disposal In the European Union electronic equipment must not be treated as domestic waste but must ...

Страница 19: ......

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...