4

Read this manual carefully before starting or using the
device. Store the manual near the device or its site of use!

• Do not use the device in potentially explosive rooms. Do not

use the device in aggressive surroundings. 

• The device is designed for indoor installation.

• Set the device in an upright and stable position.

• Ensure that the air inlet and outlet are not obstructed.

• Ensure that the side of the device where the air inlet is found

is kept free of dirt and loose objects.

• Never reach or put objects into the device.

• Do not cover or transport the device during operation.

• Ensure that all electric cables outside of the device are

protected from damage (e.g. from animals).

• Only use extensions to the connecting cable which are

appropriate to the device power consumption, the length of
its cable and its use. Avoid electrical overload.

• Only transport the device with an emptied condensation tank.

• Dispose of the collected condensation. Do not drink it. Health

hazard!

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.

Improper use

Do not place the device on wet or flooded ground. Do not use the
device outdoors or for drying rooms and areas after water
damages from burst pipes or flooding. Do not lay any objects, e.g.
wet clothing, on the device for drying. Any unauthorised changes,
modifications or alterations to the device are forbidden. 

Personnel qualifications

People who use this device must:

• be aware of the dangers that occur when working with

electric devices in damp areas.

• have read and understood the operating manual, especially

the Safety chapter.

Residual risks

Hazardous electric current!

Work on the electrical components must only be carried
out by an authorised specialist company!

Hazardous electric current!

Before any work on the device, remove the mains plug
from the mains socket!

Danger!

The device is not a toy and does not belong in the hands
of children.

Danger!

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Danger!

Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Caution!

To avoid damages to the device, never operate the
device without an air filter inserted!

Behaviour in the event of an emergency

1. Disconnect the device from the mains power in an

emergency.

2. Do not reconnect a defective device to the mains power.

Safety

Содержание TTK 29 E

Страница 1: ...OPERATING MANUAL DEHUMIDIFIER TTK 29 E TTK 51 E TTK 70 E EN TRT BA TTK29E 51E 70E TC 00 EN ...

Страница 2: ...ase replaces all previous versions No part of this publication may be reproduced without written permission from TROTEC The same applies for electronically processing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer Product names are r...

Страница 3: ...ensed water drops through the integrated drain nozzle into the condensation tank 7 below It is fitted with a float to measure the filling level Once the maximum fill level of the condensation tank 7 is reached the condensation tank indicator light see chapter Operating elements on the control panel 1 is illuminated The device switches off The condensation tank indicator light only goes out again o...

Страница 4: ...tric connection 220 to 240 V 50 Hz Power consumption max 250 W 410 W 480 W Nominal current 1 2 A 2 1 A 2 2 A Condensation tank 2 3 l Refrigerant R134a Amount of refrigerant 80 g 120 g 135 g Weight 10 7 kg 13 2 kg 13 4 kg Dimensions height x depth x width 490 x 220 x 365 mm Minimum distance to walls or other objects A Top 50 cm B Rear 50 cm C Sides 50 cm D Front 50 cm Sound pressure level LpA 1 m c...

Страница 5: ...er use Do not place the device on wet or flooded ground Do not use the device outdoors or for drying rooms and areas after water damages from burst pipes or flooding Do not lay any objects e g wet clothing on the device for drying Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that o...

Страница 6: ...he range given for the operating temperature in the chapter Technical Data Positioning When positioning the device observe the minimum distance from walls or other objects as described in chapter Technical Data Set the device in a level and stable position If possible set the device in the middle of a room and keep it away from sources of heat When positioning the device in wet areas such as laund...

Страница 7: ...ies the air constantly regardless of the moisture content The condensate is collected in the condensation tank or drained separately For separate draining both a suitable hose 1 2 and an appropriate collection container or drain are required Start the continuous operation mode as follows 1 Switch the device off 2 If you want do drain the condensate separately connect the hose see chapter Operation...

Страница 8: ...7 Operating Manual Dehumidifier TTK 29 E 51 E 70 E EN Emptying the condensation tank Operation with hose attached to the condensation connection A C B D A B C 1 2 ...

Страница 9: ...condensation tank for damages If necessary clean the float and condensation tank The float must be able to move freely Check the room temperature Check the device s permissible operating range complies with the technical data Check that the selected desired humidity level The humidity in the room must be above the selected range Reduce the preselected humidity by turning the rotary switch 12 if ne...

Страница 10: ...replace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and outlets for dirt and foreign objects and clean if necessary clean housing visually check the inside of the device for dirt check air inlet grid and air filter for dirt and foreign objects and clean or replace if necess...

Страница 11: ... dirt in the inside of the device 1 Remove the air filter see chapter Cleaning the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by TROTEC 5 Put the air filter back in Cleaning the housing and condensation...

Страница 12: ...n Ensure that the air filter is not worn or damaged The corners and edges of the air filter must not be rounded or misshaped Before reinserting the air filter ensure that it is dry and is not damaged Read the chapter Maintenance intervals and replace the air filter in due time A C B E D ...

Страница 13: ...essure pipe 6 air flowing housing 21 knob 36 foam for low pressure pipe 7 caster 22 air outlet 37 compressor 8 base 23 connection plate 38 working pipe 9 screw hat 24 back blade 39 right side panel 10 protection board 25 front blade 40 motor support 11 main pcb 26 back panel 41 upper poly foam 12 protection cover box 27 float 42 down poly foam 13 condenser 28 air filter 43 carton box 14 evaporator...

Страница 14: ... for power cord 7 motor support 22 knob 37 high pressure pipe 8 caster 23 air outlet 38 low pressure pipe 9 base 24 connection plate 39 foam for low pressure pipe 10 screw hat 25 back blade 40 compressor 11 capacitor 26 front blade 41 working pipe 12 capacitor 27 back panel 42 right side panel 13 protective shield 28 air filter 43 upper poly foam 14 main pcb 29 float 44 down poly foam 15 protectio...

Страница 15: ...let 36 low pressure pipe 7 motor support 22 connection plate 37 foam for low pressure pipe 8 base 23 back blade 38 compressor 9 capacitor 24 front blade 39 working pipe 10 capacitor 25 back panel 40 right side panel 11 protective shield 26 air filter 41 upper poly foam 12 main pcb 27 float 42 down poly foam 13 protection cover box 28 water tank 43 carton box 14 left side panel 29 capillary 15 humi...

Страница 16: ... accordance with the EC Low Voltage Directive 2006 95 EC Annex III Section B and the EC Directive 2004 108 EC about electromagnetic compatibility Herewith we declare that the dehumidifier TTK 29 E 51 E 70 E was developed constructed and produced in compliance with the named EC directives Applied harmonised standards EN 60335 2 40 A13 2012 EN 60335 1 2012 EN 62233 2008 Other applied technical stand...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: