Trotec TTK 175 S Скачать руководство пользователя страница 6

6

EN

dehumidifier TTK 175 S / TTK 355 S

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.

Note

When operated with condensation tank, make sure that
the condensation tank is inserted correctly!
If the condensation tank is removed or not installed
correctly, the device does 

not

 switch off.

Behaviour in the event of an emergency

1. Switch the device off.
2. Disconnect the device from the mains feed-in: Hold onto

the mains plug while pulling the power cable out of the
mains socket.

3. Do not reconnect a defective device to the mains.

Information about the device

Device description

The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to approx.
30 %.
The device has an operating element for operating and
controlling the functions.

Device depiction

1

2

3

5

4

11

8

6

7

9

10

Содержание TTK 175 S

Страница 1: ...TRT BA TTK175S TTK355S TC220617TTRT01 011 EN TTK 175 S TTK 355 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...indicates dangers to the life and health of persons due to electrical voltage Warning This signal word indicates a hazard with an average risk level which if not avoided can result in serious injury...

Страница 3: ...bles outside of the device are protected from damage e g caused by animals Never use the device if electric cables or the power connection are damaged The mains connection must correspond to the speci...

Страница 4: ...work require the support of additional persons the person trained in handling flammable refrigerants shall continuously supervise the work carried out The entire refrigerant circuit is a maintenance f...

Страница 5: ...ger Refrigerant R454C H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Elimina...

Страница 6: ...dehumidify rooms The fan sucks damp room air through the air inlet the air filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the...

Страница 7: ...the remaining condensate from the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Only wheel the device on firm and level surfaces Please n...

Страница 8: ...llowing storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an...

Страница 9: ...ke sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with th...

Страница 10: ...10 EN dehumidifier TTK 175 S TTK 355 S 1 2 3 4 5...

Страница 11: ...f energy consumption 14 Rotary switch Selection of relative room humidity 15 Mains switch Switching the device on and off Is illuminated when the device is switched on 16 Condensation tank LED Is disp...

Страница 12: ...is only functional after three to five minutes each time it is switched on or after the water container has been inserted 1 Ensure that the condensation drain hose is properly connected to the device...

Страница 13: ...tect e g the compressor from overheating Upper temperature limit 35 C 2 C Lower temperature limit 3 C 2 C If the ambient temperature exceeds or falls below these limits the device automatically switch...

Страница 14: ...the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Condensation tank LED 16 must not light up Check the c...

Страница 15: ...y a specialist company for cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not op...

Страница 16: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Страница 17: ...if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Eliminate all ignition sources if safe to do so P403 Store in a well ventilated place The entire refrig...

Страница 18: ...ith a neutral cleaning agent 3 Allow the filter to dry completely Do not insert a wet filter into the device 4 Reinsert the air filter into the device Emptying the condensation tank Info The compresso...

Страница 19: ...tion tank LED 16 will be illuminated The compressor and fan will switch off Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do n...

Страница 20: ...Pa Air volume flow 580 m h 580 m h 1 000 m h Mains connection 220 240 V 50 Hz 110 230 V 50 Hz 220 240 V 50 Hz Power consumption max 0 6 kW 0 6 kW 1 3 kW Nominal current 2 8 A 5 7 2 7 A 6 A Fusing 10 A...

Страница 21: ...EN 21 dehumidifier TTK 175 S TTK 355 S Wiring diagram With operating hours counter...

Страница 22: ...22 EN dehumidifier TTK 175 S TTK 355 S With operating hours counter and MID counter...

Страница 23: ...N 23 dehumidifier TTK 175 S TTK 355 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruction...

Страница 24: ...rity pin 7 Left panel 24 Electronic controller 41 Rubber feet 8 Water tank baseplate complete set 25 Main switch 42 Control panel sticker 9 Structural foot 26 Electronic controller status LED 43 Axle...

Страница 25: ...ur country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effect...

Страница 26: ...0 2003 A2 2009 EN 60335 2 40 2003 A11 2004 EN 60335 2 40 2003 A12 2005 EN 60335 2 40 2003 A13 2012 EN 60335 2 40 2003 AC 2006 EN 60335 2 40 2003 AC 2010 EN 60335 2 40 2003 AC 2013 EN 61000 3 3 2013 Ap...

Страница 27: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: