Trotec TTK 127 E Скачать руководство пользователя страница 10

10

EN

dehumidifier TTK 96 E / TTK 127 E

Setting the desired relative room humidity

The desired relative room humidity can be preselected at any
time.

1. Press the left or right-hand side of the selection button (22)

to adjust the relative room humidity level.

ð

The value for desired room humidity is indicated on the
segment display (20) for approx. 5 s.

ð

Then the currently measured humidity level reappears
on the display.

ð

The device switches off automatically upon reaching the
desired value for the relative room humidity.

Setting the fan speed

Using this function you can choose between a low and a high
fan speed. The fan speed can only be adjusted in

dehumidification

 mode. The default setting for the 

laundry

drying function

 is the highest level.

1. Press the 

TURBO

 button (24) to switch between the normal

and high fan speed.

ð

The 

TURBO

 LED (16) is illuminated when the fan runs at

high speed.

Continuous operation

The device dehumidifies the air constantly and regardless of the
current humidity level.
Please proceed as follows to enable continuous operation:

1. Press the 

CONT.

 button (25) to switch continuous operation

on or off.

ð

With activated continuous operation mode the 

CONT.

 LED (15) is illuminated.

Info

For continuous operation the condensation drain hose
can be connected in order to continuously drain the
accumulating condensate.

Comfort mode

Comfort mode ensures an agreeable humidity level ranging
between 45 % and 55 %. Depending on the room temperature
the device automatically regulates the convenient humidity level
choosing a value from 45 % - 50 % - 55 %.
In this operating mode it is not possible to regulate the humidity
level manually.

1. Press the 

COMFORT

 button (27) to switch comfort mode on

or off.

Setting the timer

For the device to switch on or off automatically after a
predefined number of hours (max. 24 hrs) you can programme
the timer.
The timer can be programmed in increments of 0.5 hours 
(0 to 10 h) or in increments of 1 hour (10 to 24 h).
The timer can be set in all operating modes.
You can activate the function regardless of the device being
switched on or off.

Note

The device must not be left unattended in a freely
accessible room with an activated timer.

Automatic switch-on

ü

The device is switched off.

1. Press the 

TIMER

 button (23) to programme automatic

switch-on.

ð

The 

On

 LED (19) is illuminated.

ð

The segment display (20) indicates the number of hours
until automatic switch-on. Standard: 

0.0

2. Press the 

Increase value

 or 

Decrease value

 selection

buttons (22) to set the desired number of hours until
automatic switch-on.

ð

The number of hours is indicated on the segment
display (20) for approx. 5 s.

ð

The timer setting equals the desired number of hours.

ð

After the predefined time, the device switches itself on.

ð

The current room humidity level is shown.

Automatic switch-off

ü

The device is switched on.

1. Press the 

TIMER

 button (23) to programme automatic

switch-off.

ð

The 

Off

 LED (18) is illuminated.

ð

The segment display (20) indicates the number of hours
until automatic switch-off. Standard: 

0.0

2. Press the 

Increase value

 or 

Decrease value

 selection

buttons (22) to set the desired number of hours until
automatic switch-off.

ð

The number of hours is indicated on the segment
display (20) for approx. 5 s. Then the current humidity
level of the room will be indicated.

3. The device keeps running until the given switch-off time

has expired or until the device is switched off manually.

ð

The timer is now set to the desired number of hours.

ð

After the predefined time, the device switches itself off.

Содержание TTK 127 E

Страница 1: ...TRT BA TTK96E TTK127E TC2015 42 005 EN TTK 96 E TTK 127 E EN OPERATING MANUAL DEHUMIDIFIER...

Страница 2: ...ity via the following link TTK 96 E https hub trotec com id 42501 TTK 127 E https hub trotec com id 42502 Safety Read this manual carefully before starting or using the device Always store the manual...

Страница 3: ...sport and storage Do not drink it Health hazard Safety warnings for devices containing flammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate...

Страница 4: ...misuse Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the operating manual espec...

Страница 5: ...to the mains Information about the device Device description The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air...

Страница 6: ...gether can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a carry handle To make the device easier to transport it is fitted with wheels...

Страница 7: ...ther devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x Device 1 x Air filter 1 x Power cable holder 1 x Hose adapter for condensation...

Страница 8: ...h the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the respective regulations Inserting the air filter Note...

Страница 9: ...level Indication of the relative room humidity level during set up Indication of the number of hours during timer programming Indication of error codes 21 POWER button Power button Switching the devi...

Страница 10: ...ss the COMFORT button 27 to switch comfort mode on or off Setting the timer For the device to switch on or off automatically after a predefined number of hours max 24 hrs you can programme the timer T...

Страница 11: ...densation connection For continuous operation or unattended dehumidification please connect the supplied condensation drain hose to the device The supplied hose is ready for use The supplied hose adap...

Страница 12: ...he power connection Check the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Full LED 17 must not be illu...

Страница 13: ...r cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not operate correctly after the...

Страница 14: ...ion tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...

Страница 15: ...c Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft...

Страница 16: ...on 26 to carry out a filter reset This is only possible when the Filter LED 13 was previously illuminated After the reset the LED goes out Emptying the condensation tank If the condensation tank is fu...

Страница 17: ...e switched back on Activities required after maintenance If you want to continue using the device Leave the device to rest for 12 to 24 hours so the refrigerant can accumulate within the compressor Wa...

Страница 18: ...side 1 0 MPa 1 0 MPa Pressure outlet side 2 6 MPa 2 6 MPa Max permissible pressure 2 6 MPa 2 6 MPa Mains connection 1 N PE 220 240 V 50 Hz 1 N PE 220 240 V 50 Hz Max power consumption 0 72 kW 1 06 kW...

Страница 19: ...EN 19 dehumidifier TTK 96 E TTK 127 E Circuit diagram TTK 96 E TTK 127 E...

Страница 20: ...N dehumidifier TTK 96 E TTK 127 E Overview of spare parts TTK 96 E Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruct...

Страница 21: ...3 4 Supporter Subassembly Of Fan Motor 1 17 Middle Partition Board Assembly 1 4 Capacitor Cap 1 17 1 Partition Board Subassembly 1 5 Capacitor Of Compressor 1 17 2 Micro Switch 1 6 Fixed Speed Rotary...

Страница 22: ...dehumidifier TTK 96 E TTK 127 E Overview of spare parts TTK 127 E Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruct...

Страница 23: ...Single Phase Asynchronous Motor 1 17 Middle Partition Board Assembly 1 3 4 Supporter Subassembly Of Fan Motor 1 17 1 Partition Board Subassembly 1 4 Capacitor Box 1 17 2 Micro Switch 1 5 Capacitor Of...

Страница 24: ...y for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separ...

Страница 25: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: