Trotec TTK 125 S Скачать руководство пользователя страница 3

EN

3

dehumidifier TTK 125 S

Insert the mains plug into a properly secured mains
socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:

dehumidifying and drying:

– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats

maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.

Improper use

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, alterations or structural
changes to the device are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the instructions, especially the
Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Note

Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

3. Do not reconnect a defective device to the mains.

Содержание TTK 125 S

Страница 1: ...TRT BA TTK125S TC2018 54 004 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...l instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be use...

Страница 3: ...chives laboratories garages bathrooms wash rooms changing rooms etc Improper use Do not place the device on wet or flooded ground Do not place any objects e g clothing on the device Do not use the dev...

Страница 4: ...ly the device may be damaged Note the information regarding transport and storage of the device Transport To make the device easier to transport it is fitted with wheels Before transporting the device...

Страница 5: ...sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residua...

Страница 6: ...6 EN dehumidifier TTK 125 S 1 2 3 4 5...

Страница 7: ...4 Condensation tank LED Is displayed when the condensation tank is full or not installed correctly 15 Status LED Indicates the operating status and error messages The device is optionally available wi...

Страница 8: ...defrost Do not remove the mains plug from the mains socket Temperature limitation overheating protection The device comes with a temperature limitation It serves to protect e g the compressor from ov...

Страница 9: ...he power cable and mains plug for damages Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Condensation tank LED 14 must not light up Check the r...

Страница 10: ...and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks...

Страница 11: ...and drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and c...

Страница 12: ...dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 5 Put the air filter back in Refrigerant circuit Th...

Страница 13: ...of the selection switch the compressor will only switch back on after a delay The fan keeps running independently of the compressor The fan only switches off if the condensation tank is removed 1 OFF...

Страница 14: ...side 4 2 MPa Air volume flow 300 m h Mains connection 1 N PE 230 V 50 Hz Power consumption max 0 6 kW Nominal current 2 6 A Water tank capacity 6 l Refrigerant R 407C Amount of refrigerant 530 g GWP f...

Страница 15: ...Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll l l o v r e t l h e B l l u f k n a T Standard Standard Tank Pr senz Zeit Z hler E N S1 S2 S3 S4 L M...

Страница 16: ...ator Time Energy Counter Water Pump Socket Wasserpumpe Stockdose e c n e s e r P k n a T Tank Full Mikroschalter Wippe Vo lstand Beh lter voll Tank Presence Z l a n o i t p O Tank Pr senz Tank Pr senz...

Страница 17: ...EN 17 dehumidifier TTK 125 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual...

Страница 18: ...nning Castor D3 Aluminium Evaporating Coil Capillary Tube Filter Drier A10 Protection Box PCB Support B10 EPS Top Plate D4 R407c Solenoid Valve A11 Protection Box Left Support B11 ABS Piece for Spring...

Страница 19: ...e national regulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 3971...

Страница 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: