Operating instructions – Infrared heating panels
G
with Section 704 of DIN VDE 0100 (VDE = Associ-
ation for Electrical, Electronic &Information Techno-
logies).
• Please remember to use a separate switch when
using more than 3 infrared panels at a time.
Do not use the panels near inflammable objects. Keep a
safe distance of at least 30 cm (12ins) between the panels
and inflammable materials like textiles, plastics, paper...
Avoid contact with water. Do not place the infrared hea-
ting panels near bath tubs, showers or sinks. Do not point
the panels at current carrying sockets. Do not at any time
cover the heating panels. Do not use the panels in rooms
in which there are inflammable gases or vapour.
The panels are equipped with a device which controls
the temperature which makes them ideal for non-
stop, continuous operation.
06. DryInG aBOve THe sTanDInG HeIGHT Of THe
HeaTInG Panels
The panels can be mounted three high to provide a
means for drying out walls or damaged areas (e.g.
following a burst pipe) above a height of 80 cm
(32ins). Such a stacked installation requires that the
panels be connected to each other:
1. First make absolutely sure that the first panel is
positioned on a flat and level surface.
2. Put the upper panel with the bolts (illustration) onto
the lower panel. Make sure that all 3 bolts grab
into the holes.
.