![Trotec TEH 100 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/trotec/teh-100/teh-100_original-instructions-manual_1171943008.webp)
8
EN
electric heater TEH 70 / TEH 100
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Proceed as described in the
Switch the device off
chapter.
2. Clean the device according to the Maintenance chapter.
3. Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Article number
Room thermostat
6.100.007.011
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
•
The motor might be defective. Have a defective motor
replaced by a specialist electrical company.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is switched on, the fan is operating, the heating
is not:
•
Check whether a heating level is selected.
•
Check whether the overheating protection has tripped, see
chapter Safety.
•
The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.
•
The heating element may be defective. If the heating
element is defective, have it replaced by a specialist
electrical company.
The fan is not running:
•
Check whether the device is switched on.
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
•
Check the fan for dirt or damages.
•
Have the motor checked by an authorised specialist
company or by Trotec. There may be a bearing damage on
the motor.
•
Check the fan blades for dirt and clean them if required
(see chapter Maintenance).
•
If the fan blades are defective, have them replaced by a
specialist company or by Trotec.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to