electric heater TEH 70 / TEH 100

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

1. Proceed as described in the 

Switch the device off

 chapter.

2. Clean the device according to the Maintenance chapter.
3. Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.

Designation

Article number

Room thermostat

6.100.007.011

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

The motor might be defective. Have a defective motor
replaced by a specialist electrical company.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is switched on, the fan is operating, the heating
is not:

Check whether a heating level is selected.

Check whether the overheating protection has tripped, see
chapter Safety.

The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.

The heating element may be defective. If the heating
element is defective, have it replaced by a specialist
electrical company.

The fan is not running:

Check whether the device is switched on.

Check the power connection.

Check the power cable and mains plug for damages.

The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Check the fan for dirt or damages.

Have the motor checked by an authorised specialist
company or by Trotec. There may be a bearing damage on
the motor.

Check the fan blades for dirt and clean them if required
(see chapter Maintenance).

If the fan blades are defective, have them replaced by a
specialist company or by Trotec.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Содержание TEH 100

Страница 1: ...TRT BA TEH70 TEH100 TC2014 30 002 EN TEH 70 TEH 100 EN ORIGINAL INSTRUCTIONS ELECTRIC HEATER ...

Страница 2: ...ked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the instructions must be observed You can download the current version of the instructions and the EU declaration of conformity via the following link TEH 70 https hub trotec com id 44020 TEH 100 https hub trotec com id 44021 Safety Read this manual careful...

Страница 3: ...r use the device if electric cables or the power connection are damaged The electrical connection must correspond to the specifications in chapter Technical data Insert the mains plug into a properly secured mains socket Observe the device s power input cable length and intended use when selecting extensions to the power cable Completely unroll extension cables Avoid electrical overload Before car...

Страница 4: ...ctrical components and to identify possible hazards from electrical and electronic systems Instructed person Instructed persons have been informed of the tasks they were entrusted with as well as of potential hazards resulting from inappropriate behaviour They are allowed to operate and transport the device and perform simple maintenance activities cleaning the housing cleaning the fan The device ...

Страница 5: ...sidual current device RCD with a nominal residual operating current not exceeding 30 mA To switch the device off proceed as described in the Switch the device off chapter Information about the device Device description The device serves to generate and to distribute warm air for speeding up drying processes and for defrosting frozen materials It can be used either in closed rooms or in dry outdoor...

Страница 6: ...ve the following Hold onto the mains plug while pulling the power cable out of the mains socket Stackable up to 3 devices may be stacked on top of one another Allow the device to cool down sufficiently When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cov...

Страница 7: ... along the back of the device Never guide the power cable along the front of the device Operation Avoid open doors and windows Stackable up to 3 devices may be stacked on top of one another Control panel 7 9 10 11 12 13 No Designation Meaning 7 Rotary switch temperature Switching the device on off Setting the heating level 9 Position 0 The device is switched off 10 Position 1 Aeration no temperatu...

Страница 8: ...mpany or by Trotec The device is switched on the fan is operating the heating is not Check whether a heating level is selected Check whether the overheating protection has tripped see chapter Safety The heating resistor might have blown Have a defective heating resistor replaced by a specialist electrical company The heating element may be defective If the heating element is defective have it repl...

Страница 9: ...ws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlet grid s for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check for damage Check attachment scre...

Страница 10: ...nts alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Visual inspection of the inside of the device for dirt 1 Use a torch to illuminate the openings of the device 2 Check the inside of the device for dirt 3 If you see a thick layer of dust have the inside of the device cleaned by a specialist electrical company or by Trotec Technical annex Technical data P...

Страница 11: ...EE Plug 380 415V 3N 50Hz G G K BR K K G G BR K BR K BR G HE 2 P 100 3 00 kW P 70 2 00 kW HE 3 P 100 3 00 kW P 70 2 00 kW HE 4 P 100 3 00 kW P 70 2 00 kW HE 5 P 100 3 00 kW P 70 2 00 kW HE 6 P 100 3 00 kW P 70 2 00 kW BR BR 3L 2L 3R R 2R S 1R T Closed 2 3 4 Closed 1 2 3 4 Closed 1 2 3 4 Closed 3 4 Closed 3 4 Closed 3 4 1L A A Closed 1 2 3 4 IS 4L 5L 5 4R 4 Closed 2 4 Closed 3 Closed 4 IS M 400V 50H...

Страница 12: ...Castor with Brake A3 Yellow RAL1021 Painted Side panel B4 Loose Spinning Castor A4 Black Painted Hood Ø300mm Hose Connection C1 3kW Heating Element TEH100 2kW Heating Element TEH70 A5 Motor Fan Support A6 Heating Element Base Plate C2 Motor Fan A7 Black Painted Control Panel C4 4μF Starting Capacitor A8 Air Outlet Protection Shield C5 4 Positions 3ph Cam Switch A9 Ø300 Aluminium Fan Blade Pitch 24...

Страница 13: ...mity The signed declaration of conformity can be found at https hub trotec com id 44020 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A Herewith we Trotec GmbH declare that the machinery designated below was developed constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006 42 EC Prod...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: